Refinar búsqueda
Resultados 21-30 de 711
Robustesse des Filtres plantés de roseaux soumis aux variations de charges estivales des campings | Robustness of vertical Reed Bed Filters facing loads variations: the particular case of campsites
2010
Boutin, Catherine | Prost Boucle, S. | Boucher, M.
This paper presents the key elements that emerged from a 3-year study on 4 campsites. Each of them has its own Vertical-Flow Constructed Wetlands (VFCW) for on-site wastewater treatment. Each year, the pollution discharge peaked in the 5 to 6-week summer period but was zero for a 6-month period. The natural-concentrate wastewater is collected into a short sewer network. Hydraulic load and campground occupancy rate were tightly correlated. The effluent has a characteristically high nitrogen concentration due to the lower greywater-producing activity. These quantitative and qualitative elements were used to define the camper equivalent' as a daily pollutant load of about 100 L water, 90 gCOD, 35 gBOD5, 40 gSS, 11 gKN and 1.4 gPt. During the 5-6 weeks of peak visitor traffic, the full first stage receives an organic load of 200 gCOD.m-2.d-1 and 25 gKN.m-2.d-1, which is 2 to 3.5-fold higher than the loads conventionally applied in VFCW systems in France. Despite these heavy loads, COD removal remains constant (at 91%) over the season. During the summer peak, nitrification drops sharply but KN removal rate holds steady near 60%. This study demonstrates that VFCWs can robustly handle massive load increases. The paper concludes that total system size can be downscaled to 0.75 m²/camper. This design allows to reach minimum yields of 75% KN, provided that the system is built and run to state-of-the-art rules. | Cet article présente les éléments clés issus d'une étude de 3 ans sur 4 campings qui traitent leurs eaux usées de manière individuelle par des Filtres Plantés de Roseaux à écoulement vertical (FPRV) aux dimensionnements différents. La charge hydraulique et le taux d'occupation du camping sont étroitement corrélés. L'émission est nulle 6 mois par an et la pointe estivale dure 5 à 6 semaines. Les eaux usées, collectées par un réseau court sont naturellement concentrées. L'effluent présente notamment une très forte concentration en azote du fait d'une activité ménagère réduite. Ces éléments qualitatifs et quantitatifs permettent de définir l' « équivalent campeur » par une charge de pollution journalière d'environ 100 L d'eau, 90 g de DCO, 35 g de DBO5, 40 g de MES, 11 g de NK et 1,4 g de Pt. Au cours des 5-6 semaines de fréquentation maximale, la totalité du 1er étage reçoit une charge organique d'environ 200 gDCO.m-².j-1 et 25 gNK.m-².j-1, soit 2 à 3,5 fois plus que les charges classiques appliquées en FPRV en France. En dépit de ces fortes charges, l'élimination de la DCO reste constante (91 %) au cours de la saison. Lors du pic de fréquentation estival, la nitrification décroît fortement mais le rendement global se maintient à environ 60 %. La robustesse des FPRV face à une augmentation massive des charges appliquées est démontrée. L'article conclut par un dimensionnement réduit de 0.75 m2/campeur au total. Ce dimensionnement permet d'atteindre un rendement minimum de 75 % du NK, correspondant à la nitrification, sous réserve que les règles de l'art de construction et d'exploitation soient strictement respectées.
Mostrar más [+] Menos [-]Dégradation des indicateur bactériens et virales sur filtres plantés de roseaux à écoulement vertical et horizontal | Removal of bacterial and viral indicators in horizontal and vertical subsurface flow constructed wetlands
2010
Torrens, A. | Folch, M. | Sasa, J. | Lucero, M. | Huertas, E. | Molle, Pascal | Boutin, Catherine | Salgot, M.
Subsurface horizontal flow constructed wetlands (HFCW) and vertical flow constructed wetlands (VFCW) have been compared regarding their efficiencies on microbiological indicators removal. Seven types of HFCWs and two types of VFCWs have been monitored for several years. Fecal coliforms, E. coli, somatic coliphages and F-specific bacteriophages were analyzed in the influent and effluents of each system. All constructed wetlands monitored were planted with Phragmites australis but have different design characteristics and operation variables. All data were statistically treated (SPSS v17) in order to analyse the effect of design and operation variables on each microbiological indicator. VFCWs were more efficient than HFCWs systems when considering removal rates per surface for all the microbiological indicators (cfu or pfu removed/m2.d). Nevertheless, considering mean removal efficiencies (in log units), results did not show statistically significant differences. The hydraulic retention time was the key parameter regarding filter disinfection capacity in both types of filters. Bacterial indicators were removed at a higher rate than viral indicators.
Mostrar más [+] Menos [-]Phosphorus removal by the use of apatite in constructed wetlands: design recommendations. | Rétention du phosphore par apatite en filtres plantés de roseaux : recommandations de dimensionnement
2010
Molle, Pascal | Martin, S. | Esser, D. | Besnault, S. | Morlay, C | Harouiya, N.
Phosphorus (P) removal in constructed wetlands (CWs) has received particular attention during the last decades by using specific materials which promote P adsorption/precipitation phenomena. Recent studies have shown an interest in using apatite materials to promote P precipitation onto their surface. About ten years of experiments at different scales (laboratory, pilot, full scale) have passed. The process is now open in France. This paper presents the first design recommendations according to the apatite mineral quality and treatment outlet requirements. Kinetics and their evolution with the material saturation degree are presented based on the k-C* model. The process can achieve 1 mgP.l-1 for long term while using surface P removal filter area of 0.5 m².p.e.-1. With a low land footprint and high P removal efficiency, the interest of the process also result in the orthophosphates accumulation on a phosphate mineral which makes easier to reuse phosphorus from wastewater once saturated.
Mostrar más [+] Menos [-]Respirométrie solide pour mesurer l'activité biologique au sein de filtres plantés de roseaux à écoulement vertical en vue de la modélisation dynamique | Solid respirometry to characterise the biodegradation kinetics in Vertical Flow Constructed Wetland (VFCW): a better insight for modelling
2010
Morvannou, A. | Choubert, J.M. | Forquet, N. | Philippe, N. | Van Clooster, M. | Molle, Pascal
We develop an original solid respirometric method to measure the biodegradation rates of COD and ammonium at different depths of a Vertical Flow Constructed Wetland (VFCW). The method is developed for a matrix operated under unsaturated conditions. The oxygen demand is measured versus time in a gas passing through a reactor containing a mixture of an organic matrix mixed with a bulking agent (wood). For the measurement of the nitrification rate, a solution of ammonia and hydrogenocarbonates is spread on the sample. We ran 15 experiments on different matrices with variable organic matter contents (sludge, VFCW gravels and sand). Within this paper we present the overall methodology, the factors that allow improving the accuracy (number of duplicates, blank, sample volume, bulking agent volume, gas flow, etc.) and the nitrification rates that were obtained.
Mostrar más [+] Menos [-]Transport diphasic de l'oxygène en milieu poreux : approche de modélisation et de validation expérimental sur filtres plantés de roseaux à écoulement vertical | Diphasic oxygen transport in porous media: modeling approach, and vertical flow constructed wetlands experimental validation
2010
Petitjean, Anne | Wanko, A. | Forquet, N. | Mose, R.
Oxygen renewal, as a prominent phenomenon for aerobic bacteria activity, deeply impacts VFCW treatment efficiency. We introduce MIGRA, a new model able to simulate oxygen transfer in VFCW. It is based on a realistic two-phase flow module, that allows us to describe various loading sequences, and a transport module. The multi-component transport module is able to deal with convection/diffusion phenomena, inter-phase (air-water) mass exchange, and first-order kinetics. It is validated with analytical solutions and data from an experimental VFCW (column). We show the benefits of a two-phase flow modeling using a comparison with HYDRUS.
Mostrar más [+] Menos [-]Réduction de l'emprise au sol des filtres plantés de roseaux pour le traitement des eaux usées brutes : le Bi-filtre | Reducing the footprint of vertical flow constructed wetlands for raw sewage treatment: the Bi-filter® solution
2010
Troesch, S. | Prost Boucle, S. | Molle, Pascal | Leboeuf, V. | Esser, D.
French vertical flow constructed wetlands treating raw wastewater have been developed successfully over the last 30 years. During the last years, SINT and Epur Nature developed the approach further by introducing a deep single-stage vertical flow bed that comprises both stages into one in the aim to reduce the footprint. This process, patented by Epur Nature as Bi-filtre®, consists in two vertical stages piled-up. While classical systems in France are designed with 2m².PE-1 (1.2m² and 0.8m² on the first and second stage respectively), the Bi-filtre® has a larger total filtration area with 2.5 m²/PE (1.5m² and 1 m² on the first upper and second lower stage respectively) but a foot print reduced to 1.5 m².PE-1. To favour aeration of the system, an intermediate natural aeration system is introduced at the interface between the first and second stage. The paper will present a study on a fullscale plant (Saint Michel l'Observatoire, 175 PE, France) running at full load in which different materials (sand, pozzolana of different particle size) were tested at the second stage. The aim was to identify the best materials to use to guarantee performance and avoid clogging on this unplanted and buried stage. The study consisted in measuring hydraulic conditions (inlet/outlet flows, infiltration rates, tracer experiments) correlated with 24h composite samples assessments. The results shows that such systems, if well designed, can guarantee an outlet quality of 35 mg.L-1 in SS, 125 mg.L-1 in COD, 25 mg.L-1 in BOD and 20 mg/L in KN with a total foot print of 1.5 m².PE-1. The paper will present the design recommendations and the limits of the systems taking into account a larger experience gathered on different existing plants (e.g. Chorges Bifilter®, 2 150 P.E, France).
Mostrar más [+] Menos [-]Towards a critical ozone flux for forest trees
2010
Braun, Sabine | Emberson, Lisa | Bueker, Patrick | Schindler, Christian | Rihm, Beat | Goerg, Madeleine | Oksanen, Elina | Le Thiec, Didier, | Karlsson, Per Erik | Leuzinger, Sébastian
Effect of grass cover on water and pesticide transport through undisturbed soil columns, comparison with field study (Morcille watershed, Beaujolais)
2010
Dousset, S. | Thevenot, M. | Schrack, D. | Gouy, V. | Carluer, N. | Laboratoire des Interactions Microorganismes-Minéraux-Matière Organique dans les sols (LIMOS) ; Université Henri Poincaré - Nancy 1 (UHP)-Centre National de la Recherche Scientifique (CNRS) | Université de Lille, Sciences et Technologies | Unité expérimentale SAD - Station de Mirecourt (MIRECOURT) ; Institut National de la Recherche Agronomique (INRA) | Milieux aquatiques, écologie et pollutions (UR MALY) ; Institut national de recherche en sciences et technologies pour l'environnement et l'agriculture (IRSTEA)
[Departement_IRSTEA]Eaux [TR1_IRSTEA]ARCEAU | The purpose of this work is to assess the effectiveness of two grass covers (buffer zone and grass-covered inter-row), to reduce pesticide leaching, and subsequently to preserve groundwater quality. Lower amounts of pesticides leached through grass-cover soil columns (2.7e24.3% of the initial amount) than the bare soil columns (8.0e55.1%), in correspondence with their sorption coefficients. Diuron was recovered in higher amounts in leachates (8.9e32.2%) than tebuconazole (2.7e12.9%), in agreement with their sorption coefficients. However, despite having a sorption coefficient similar to that of diuron, more procymidone was recovered in the leachates (10.2e55.1%), probably due to its facilitated transport by dissolved organic matter. Thus even in this very permeable soil, higher organic matter contents associated with grass-cover reduce the amount of pesticide leaching and limit the risk of groundwater contamination by the pesticides. The results of diuron and tebuconazole transfer through undisturbed buffer zone soil columns are in agreement with field observations on the buffer zone.
Mostrar más [+] Menos [-]Vertical Flow Constructed Wetlands fed with raw sewage: historical review and recent developments in France
2010
Liénard, A.
This paper relates to the 1st studies conducted in France on Vertical Flow Constructed Wetlands [VFCWs]. This process was originally designed by Käte Seidel according to her previous research done in Krefeld (Germany) the so-called Max Planck Institute Process [MPIP]. Based on measurements campaigns done successively in Saint Bohaire and Pont-Rémy, it was clearly established that the vertical flow 1st stage filters were significantly more efficient than the horizontal ones. This acknowledgement of success was positively used to design a treatment plant in Gensac la Pallue, still in operation after 23 years, with the special feature that the VFCW are fed with raw sewage. This attribute was then spread to the design of French VFCW systems. The main reasons which explain why representatives of small communities are so enthusiastic about feeding with raw sewage are presented. The state of the art of French VFCWs is detailed and scientific arguments which nowadays lead to new fields of application and a better understanding of small scale processes which occurs in these filters are also suggested.
Mostrar más [+] Menos [-]Sludge drying reed beds for septage treatment: towards design and operation recommendations
2010
Vincent, J. | Molle, Pascal | Wisniewski, C. | Liénard, A. | Milieux aquatiques, écologie et pollutions (UR MALY) ; Institut national de recherche en sciences et technologies pour l'environnement et l'agriculture (IRSTEA) | Génie des procédés et d'élaboration de bioproduits (UMR GPEB) ; Centre de Coopération Internationale en Recherche Agronomique pour le Développement (Cirad)-Université Montpellier 1 (UM1)-Université Montpellier 2 - Sciences et Techniques (UM2)
[Departement_IRSTEA]Ecotechnologies [TR1_IRSTEA]TED [Axe_IRSTEA]TED-EPURE | International audience | With decentralized treatment system development, a new concern emerges: the future of the septage. The aim of this paper is to assess the feasibility of septage treatment by SDRB, and to compare its efficiencies to those of activated sludge treatment in same conditions. The study took place on ten 2m² pilot-scales SDRB. Different designs and operation conditions have been tested on sludge treatment efficiency and will be presented as: (i) the top filtration layer (sand or compost), (ii) the load (from 30 to 50 kgSS/m-2/y). After one year and half commissioning period, we focus on the results obtained at nominal loads presenting: sludge characteristic, filtration efficiency, percolate quality and sludge deposit behaviour. Although results show better filtration efficiency for activated sludge (98.4%) than for septage (87.5%), the feasibility of septage treatment with drying reed bed has been demonstrated. Sludge accumulation is about 7.9 cm/y, when fed at 50 kgSS/m-2/y, and dry matter content of the sludge can reach 70% in summer period. The paper will present sludge characteristics, system efficiency, to finish on design and operation condition recommendations for SDRB treating septage.
Mostrar más [+] Menos [-]