This study was conducted to determine the optimal conditions for PAH degradation from highly contaminated attrition sludge (PAC) using a Fenton process or successive permanganate (KMnO₄) oxidation and Fenton processes. The following parameters were studied to optimize the Fenton oxidation process: the amounts of reactants based on the stoichiometric oxidant demand (SOD), the reactant addition protocol and number of doses, and the solid/liquid ratio (S/L). The results showed that the following conditions were optimum: TS = 30%, 7.5 times SOD, H₂O₂/Fe²⁺ ratio = 10, and added five times during 60 min, which allowed the degradation of 43% of total 27 PAHs from the PAC. Successive Fenton and KMnO₄ oxidation processes were also tested. PAH degradation using a sequential Fenton process followed by KMnO₄ oxidation (or KMnO₄ followed by Fenton) was higher than for the use of Fenton or KMnO₄ treatment alone. Up to 71% of the total 27 PAHs were degraded when using a combination of both processes. It appeared that the sequential treatment is a viable method for the significant degradation of 27 PAHs from PAC (t value > 2.77).