Temperature sensor placement errors in institutional size retort pouches
1985
Peterson, Wayne R. | Adams, J.P.
A study examined the sensitivity of process time to the position of temperature measurement in the conduction-heating of low-acid foods processed in institutional-size retort pouches. It also assessed the allowable error in temperature measurement position that would not significantly affect processing time, using numerical techniques. Positioning was found to be not critical when the temperature sensing probe was in the order of 0.32 cm around the pouch center, resulting in a relatively constant processing time. (wz)
Afficher plus [+] Moins [-]Mots clés AGROVOC
Informations bibliographiques
Cette notice bibliographique a été fournie par National Agricultural Library
Découvrez la collection de ce fournisseur de données dans AGRIS