Indoor Air Quality Assessment of Elementary Schools in Curitiba, Brazil
2009
Godoi, R. H. M | Avigo, D Jr | Campos, V. P | Tavares, T. M | de Marchi, M. R. R | Van Grieken, R | Godoi, A. F. L
The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO₂; SO₂; O₃; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatography-ion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO₂ varied between 9.5 and 23 µg m⁻³, whereas SO₂ showed an interval from 0.1 to 4.8 µg m⁻³. Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5 µg m⁻³ and 1.2 µg m⁻³, respectively.
Afficher plus [+] Moins [-]Mots clés AGROVOC
Informations bibliographiques
Cette notice bibliographique a été fournie par National Agricultural Library
Découvrez la collection de ce fournisseur de données dans AGRIS