Calibration of moisture meters for baldcypress (Taxodium distichum)
1997
Wu, Q.
Correction factors for resistance- and capacitance-type moisture meters were determined for baldcypress (Taxodium distichum). The correction factors can be used with most resistance-type meters and the Wagner L-612 capacitance-type moisture meter, in the range from 6 to 26 percent moisture content.
Afficher plus [+] Moins [-]Mots clés AGROVOC
Informations bibliographiques
Cette notice bibliographique a été fournie par National Agricultural Library
Découvrez la collection de ce fournisseur de données dans AGRIS