Affiner votre recherche
Résultats 1-5 de 5
Correlation of Activity Data in Normal Dogs to Distance Traveled
2020
Eskander, Bishoy S. | Barbar, Megan | Evans, Richard B. | Enomoto, Mastaka | Lascelles, B. Duncan X. | Conzemius, Michael G.
The objective of this study was to explore the mathematical relationships between independent variables (patient morphometrics and treadmill speed) and dependent variables (accelerometer or pedometer output) when evaluating data from accelerometers and pedometers in dogs. Twenty dogs took part in 3 randomized activities, consisting of exercise on a treadmill at 1.0, 1.5, and 2.0 m/s for a total distance of 1 km at each speed. Dogs simultaneously wore both an accelerometer and a pedometer. Statistical analysis used multiple regression models to discover the relationships between independent and dependent variables. A formula was developed to predict the distance traveled by a dog based on its morphometrics and activity monitor output. Shoulder height had stronger correlations to accelerometer and pedometer outputs than other morphometric variables. As shoulder height increased, all accelerometer and pedometer outputs decreased. As treadmill speed increased, both accelerometer and pedometer step counts decreased, while accelerometer activity counts increased. According to a formula derived to predict the total distance traveled using patient shoulder height and accelerometer or pedometer output, pedometer steps were the most accurate predictor of distance traveled. Accelerometer steps were less accurate when using the same model. Accelerometer activity counts did not reveal a meaningful predictive formula. The results of this study indicate that patient morphometrics and treadmill speed (as a measure of intensity) influenced accelerometer and pedometer data. The pedometer data more precisely and accurately estimated the distance traveled based on step counts and patient shoulder height. In normal dogs, accelerometer and pedometer steps may reasonably estimate distance traveled.
Afficher plus [+] Moins [-]Determination of the pharmacokinetics of a single oral dose of trazodone and its effect on the activity level of domestic pigeons (Columba livia)
2019
OBJECTIVE: To determine the pharmacokinetics of a single oral dose of trazodone and its effect on the activity of domestic pigeons (Columba livia). ANIMALS: 6 healthy adult male domestic pigeons. PROCEDURES: During the first of 3 experiments, birds received orally administered trazodone at doses ranging from 3 to 30 mg/kg to determine the dose for subsequent experiments. During the second experiment, each bird received 1 dose of trazodone (30 mg/kg, PO). Blood was collected for determination of plasma trazodone concentration before and at predetermined times for 24 hours after drug administration. Pharmacokinetic parameters were calculated by noncompartmental analysis. During experiment 3, birds were instrumented with ultralightweight accelerometers and received orally administered trazodone (30 mg/kg) or an equal volume of water twice at a 48-hour interval. Activity of birds was monitored for 24 hours after administration of each treatment. RESULTS: No adverse effects were observed. Mean ± SD terminal half-life of trazodone was 5.65 ± 1.75 hours. Plasma trazodone concentrations remained > 0.130 μg/mL for approximately 20 hours. Trazodone did not affect the activity of birds during the first 2 and 15 hours after administration. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that oral administration of 1 dose (30 mg/kg) of trazodone to healthy pigeons was safe and resulted in plasma drug concentrations that were similar to those considered therapeutic in humans and dogs for up to 20 hours. Further research is necessary to characterize the pharmacokinetics for repeated doses as well as the clinical effects of trazodone in birds with behavior problems.
Afficher plus [+] Moins [-]Effects of stacked wedge pads and chains applied to the forefeet of Tennessee Walking Horses for a five-day period on behavioral and biochemical indicators of pain, stress, and inflammation
2018
Everett, James B. | Schumacher, Jim | Doherty, Thomas J. | Black, Randi A. | Amelse, Lisa L. | Krawzel, Peter | Coetzee, Johann F. | Whitlock, Brian K.
OBJECTIVE To determine the effects of stacked wedge pads and chains applied to the forefeet of Tennessee Walking Horses on behavioral and biochemical indicators of pain, stress, and inflamation. ANIMALS 20 Tennessee Walking Horses. PROCEDURES Horses were randomly assigned to 2 treatment groups: keg shoes (control; n = 10) or stacked wedge pads and exercise with chains (10). Ten days before treatment application, an accelerometer was attached at the left metatarsus of each horse to record daily activity. Horses were exercised for 20 minutes daily, beginning on day -7. On day 0, exercise ceased, the forefeet were trimmed, and the assigned treatment was applied. From days 1 through 5, horses were exercised as before. Blood samples for measurement of plasma cortisol, substance P, and fibrinogen concentrations were collected on days -5, 1, and 5 before and after exercise and every 30 minutes thereafter for 6 hours. RESULTS No significant differences in plasma concentrations of cortisol, substance P, and fibrinogen were detected between groups. Although lying behaviors changed after shoes were applied, these behaviors did not differ significantly between groups. Shoeing appeared to have altered behavior to a greater extent than did the type of treatment applied. CONCLUSIONS AND CLINICAL RELEVANCE Application of stacked wedge pads and chains to the forefeet of horses for a 5-day period as performed in this study evoked no acute or subacute stress or nociceptive response as measured. Although these findings should not be extrapolated to the long-term use of such devices in Tennessee Walking Horses performing the running walk, the data should be considered when making evidence-based decisions relating to animal welfare and the use of stacked wedge pads and chains.
Afficher plus [+] Moins [-]Evaluation of a portable media device for use in determining postural stability in standing horses
2017
Moorman, Valerie J. | Kawcak, Christopher E. | King, Melissa R.
OBJECTIVE To determine the ability of an accelerometer within a commercially available portable media device (PMD) to measure changes in postural stability of standing horses during various stance conditions and to compare these results with data obtained by use of a stationary force platform. ANIMALS 7 clinically normal horses. PROCEDURES A PMD was mounted on a surcingle; the surcingle was placed immediately caudal to the highest point of the shoulders (withers). Each horse was examined while standing on a stationary force platform system in a normal square stance, forelimb base-narrow stance, and normal square stance at 5 and 10 minutes after sedation induced by IV administration of xylazine hydrochloride. A minimum of 5 trials were conducted for each stance condition. Ranges of craniocaudal and mediolateral motion as well as SDs were collected for the PMD and force platform system. Analyses were performed with mixed-model ANOVAs, and correlation coefficients were calculated. RESULTS Stance condition significantly altered craniocaudal accelerations measured by use of the PMD, all craniocaudal and mediolateral displacements of the center of pressure, and velocities measured by use of the stationary force platform. For both the PMD and force platform, SDs were significantly affected by stance condition in both craniocaudal and mediolateral directions. Correlation coefficients between the systems for all variables were low to moderate (r = 0.18 to 0.58). CONCLUSIONS AND CLINICAL RELEVANCE Body-mounted PMDs should be investigated for use in assessment of postural stability in horses with neuromuscular abnormalities.
Afficher plus [+] Moins [-]Effects of low-level laser therapy on bone healing and signs of pain in dogs following tibial plateau leveling osteotomy
2018
Kennedy, Katie C. | Martinez, Steven A. | Martinez, Stephanie E. | Tucker, Russell L. | Davies, Neal M.
OBJECTIVE To assess the effect of low-level laser therapy (LLLT) on markers of synovial inflammation and signs of pain, function, bone healing, and osteoarthritis following tibial plateau leveling osteotomy (TPLO) in dogs with spontaneous cranial cruciate ligament rupture (CCLR). ANIMALS 12 client-owned dogs with unilateral CCLR. PROCEDURES All dogs were instrumented with an accelerometer for 2 weeks before and 8 weeks after TPLO. Dogs were randomly assigned to receive LLLT (radiant exposure, 1.5 to 2.25 J/cm2; n = 6) or a control (red light; 6) treatment immediately before and at predetermined times for 8 weeks after TPLO. Owners completed a Canine Brief Pain Inventory weekly for 8 weeks after surgery. Each dog underwent a recheck appointment, which included physical and orthopedic examinations, force plate analysis, radiography and synoviocentesis of the affected joint, and evaluation of lameness and signs of pain, at 2, 4, and 8 weeks after surgery. Select markers of inflammation were quantified in synovial fluid samples. Variables were compared between the 2 groups. RESULTS For the control group, mean ground reaction forces were greater at 2 and 4 weeks after TPLO and owner-assigned pain scores were lower during weeks 1 through 5 after TPLO, compared with corresponding values for the LLLT group. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the LLLT protocol used had no beneficial effects on signs of pain or pelvic limb function following TPLO. Further research is necessary to evaluate the effects of LLLT and to determine the optimum LLLT protocol for dogs with CCLR.
Afficher plus [+] Moins [-]