Affiner votre recherche
Résultats 21-30 de 35
Pharmacokinetic model for predicting sulfamethazine disposition in pigs
1993
Sweeney, R.W. | Bardalaye, P.C. | Smith, C.M. | Soma, L.R. | Uboh, C.E.
Concentration of sulfamethazine was measured in plasma and tissues (fat, liver, kidney, spleen, lungs, and skeletal muscle) of pigs given the drug IV and PC. The plasma concentration vs time curve was best described by a 2-compartment model, with a distribution half-life of 0.46 hour and an elimination half-life of 16.9 hours. Bioavailability after oral administration was 85.8 +/- 5.3%. The tissue and plasma sulfamethazine concentration vs time data ,ere used to develop a multicompartment pharmacokinetic model of sulfamethazine disposition in pigs. Plasma and tissue concentrations of sulfamethazine in pigs were measured at various intervals after multiple oral doses of sulfamethazine, and were compared to concentrations predicted by the model. Model predictions for tissue concentrations of sulfamethazine after addition of the drug to feed (110 micrograms/g of feed for 98 days; 550 micrograms/g for 30 days) were compared to results from other studies. The model accurately predicted the number of days for sulfamethazine concentration to fall below 0.1 Kg of tissue/g (0.1 ppm. the tolerated concentration) in various tissues.
Afficher plus [+] Moins [-]Bioelectrical impedance and zoometry for body composition analysis in domestic cats
1992
Stanton, C.A. | Hamar, D.W. | Johnson, D.E. | Fettman, M.J.
Zoometric measurements and bioelectrical impedance analysis were evaluated as methods of body composition determination in healthy cats. Zoometric and impedance measurements were taken on 22 anesthetized adult cats of various ages, genders, breeds, and body weights. The cats were then euthanatized. The bodies were processed through a tissue homogenizer and free-catch specimens were taken, freeze-dried, and analyzed for total body water, protein, fat, potassium, and ash content. Stepwise regression analysis was implemented to identify statistically significant relationships between the chemically determined dependent variables (total body water, protein, potassium, fat-free mass, fat mass, and percent body fat) and the zoometric measurements, with or without bioelectrical impedance analysis. Statistical analysis revealed high correlations between the dependent variables and the corresponding predicted values of those variables. Body weight alone was a poor predictor of body composition in these cats. On the basis of these findings, we suggest that zoometric and bioelectrical impedance measurements may serve as practical, noninvasive, simple, and accurate methods for estimating body composition in domestic cats.
Afficher plus [+] Moins [-]Quantitation of canine plasma von Willebrand factor antigen using a commercial enzyme-linked immunosorbent assay
1991
Johnstone, I.B. | Crane, S.
The purpose of this study was to evaluate a commercial enzyme-linked immunosorbent assay (ELISA) for human von Willebrand factor antigen (vWF:Ag) with respect to its potential value in quantitating the protein in canine plasma. The assay was a sandwich technique using F(ab')2 fragments specific for von Willebrand factor (vWF) and a peroxidase conjugated rabbit anti-vWF second antibody, with a microplate as the support surface. Canine plasmas were assayed by ELISA, and by Laurell electroimmunoassay (EIA), our reference methodology. The ELISA had a within-day variation of 1.21-4.44% and a between-day variation of 0.85-4.88% depending on the level of vWF:AG. The sensitivity of the assay was less than 0.1% vWF:AG. The range of vWF:AG concentrations in plasmas from 24 clinically normal dogs compared favorably with the range for the same plasmas when assayed by EIA (ELISA = 60-152% of normal; EIA = 50-142% of normal). In 121 canine plasmas with vWF:AG concentrations (as assessed by EIA) ranging from undetectable levels (< 6% of normal) to 142% of normal, there was good correlation with measurements made by ELISA (correlation coefficient = 0.835). It was concluded that this commercial ELISA technique could be used to provide reliable, same-day measurements of canine plasma vWF:AG. Since it requires no special equipment other than a microplate reader and washer it is particularly suitable for laboratories lacking the electrophoretic expertise or equipment required for EIA.
Afficher plus [+] Moins [-]Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Afficher plus [+] Moins [-]Oral administration of sucrose solutions and measurement of serum sucrose concentrations to evaluate gastric permeability in adult bottlenose dolphins (Tursiops truncatus)
2006
Buddington, K.K. | Holmes, W.E. | Clemons-Chevis, C.L. | Solangi, M.A. | Vanderpool, D. | Buddington, R.K.
Objective-To measure concentrations of sucrose in the serum of captive dolphins after oral administration of a sucrose solution and determine the suitability of this method for use as a test to detect gastric ulcers. Animals-8 adult captive bottlenose dolphins (Tursiops truncatus). Procedures-Blood samples were collected from the ventral fluke vein of dolphins before and 45 minutes after oral administration of 500 mL of solution containing 25 or 50 g of sucrose; oral administration was achieved by use of gastric intubation. Serum was separated, diluted in a solution of 90% acetonitrile-to-10% water that contained 10 ng of an internal standard (trichlormethiazide)/microliter, mixed, and centrifuged. Supernatant was analyzed by use of liquid chromatography-mass spectrometry-mass spectrometry (LC-MS-MS). Results-Serum sucrose concentrations of dolphins were at or less than the limits of detection before oral administration. Values after administration of sucrose solution varied among dolphins and were higher and more variable after administration of 50 g, compared with concentrations after administration of 25 g. Conclusions and Clinical Relevance-Serum sucrose concentrations in samples collected during routine health evaluations of captive dolphins can be reliably measured by use of LC-MS-MS. Correlating serum sucrose concentrations with endoscopic observations of the gastric mucosa of dolphins will validate this approach for use in screening for the prevalence and severity of gastric ulcers and determining the efficacy of treatment regimens.
Afficher plus [+] Moins [-]Effect of intensity of fecal pat sampling on estimates of Escherichia coli O157 prevalence
2005
Echeverry, A. | Loneragan, G.H. | Wagner, B.A. | Brashears, M.M.
To evaluate site-to-site variation within fecal pats from cattle with regard to detection of Escherichia coli O157 and determine the effect on the accuracy of prevalence estimates of assay of multiple samples collected from the same fecal pat. 120 freshly voided fecal pats collected from 2 beef feedlots. Procedures-5 samples were systematically collected from each fecal pat and analyzed for E coli O157 via selective preenrichment techniques, immunomagnetic separation, and biochemical tests. Presumptive isolates were definitively identified via agglutination assays and polymerase chain reaction techniques. Best estimators of prevalence were calculated from the distribution of E coli O157-positive samples per pat. Of the 120 fecal pats, 96, 13, 4, 2, 3, and 2 fecal pats had 0, 1, 2, 3, 4, and 5 E coli O157-positive samples, respectively. The greatest estimate of E coli O157 prevalence (20%) was achieved when all 5 samples were assessed; this estimate represented a 2.4- fold increase in prevalence, compared with that provided via analysis of 1 sample/pat (8.2%). Compared with assessment of 5 sites/pat, the relative sensitivity of detecting an E coli O157-positive fecal pat via analysis of 1 site/pat was 40.1%. Results suggest that estimates of E coli O157 prevalence derived from sampling of 1 location/pat are likely underestimates of the true prevalence of this pathogen in fecal pats (and by extension, cattle). Additional research is warranted to confirm these results in situations of high and low prevalence and across different feedlots.
Afficher plus [+] Moins [-]Ultrasonography as a method to determine tendon cross-sectional area
1995
Gillis, C. | Sharkey, N. | Stover, S.M. | Pool, R.R. | Meagher, D.M. | Willits, N.
Ultrasonographic cross-sectional area (CSA) measurements of equine superficial digital flexor (SDF) tendon were obtained to determine the feasibility of ultrasonography for CSA measurement of tendon in vivo and in vitro. Ultrasonographic measurements were compared with a more traditional CSA measurement method, ink-blot analysis. In addition, values for ultrasonographic SDF tendon mean echogenicity were obtained in vivo and in vitro. The left forelimb SDF tendons of 23 horses were evaluated ultrasonographically. Cross-sectional images were acquired at 4-cm intervals distal to the base of the accessory carpal bone (DACB) to the level of the proximal sesamoid bones while horses were standing squarely. After euthanasia, the left forelimbs were mounted in a materials testing system (MTS) and loaded under tension to standing load. Ultrasonographic images were again acquired at the same locations. The ultrasonographic images were digitized, and values for ultrasonographic CSA and mean echogenicity were obtained for each level. Immediately after mechanical testing, a 1-cm-thick transverse section of SDF tendon at 12 cm DACB was removed. Three ink blots were prepared from each end of the removed tendon section and digitized. The 6 CSA values were averaged to generate a value for morphologic CSA for each SDF tendon at 12 cm DACB. Standing ultrasonographic tendon CSA at 12 cm DACB was consistently smallest (mean +/- SD CSA = 86 +/- 11 mm2), followed by MTS ultrasonographic CSA (mean, 95 +/- 12 mm2), with ink-blot morphologic CSA being largest (mean, 99 +/- 15 mm2). Comparison of standing and MTS ultrasonographic values at 12 cm DACB revealed a strong positive linear correlation between methods (R2 = 0.74, P = 0.001). Comparison of ink-blot CSA at 12 cm DACB with standing and MTS ultrasonographic CSA revealed strong positive linear correlations (R2 = 0.64, P = 0.001 and R2 = 0.72, P = 0.001, respectively). For ultrasonographic mean echogenicity, standing values insignificantly exceeded MTS values at each level. The authors conclude that ultrasonography is a useful technique for the noninvasive assessment of SDF tendon CSA that can be applied in vivo and in vitro.
Afficher plus [+] Moins [-]Comparison of the sensitivity of the caudal fold skin test and a commercial gamma-interferon assay for diagnosis of bovine tuberculosis
1995
Whipple, D.L. | Bolin, C.A. | Davis, A.J. | Jarnagin, J.L. | Johnson, D.C. | Nabors, R.S. | Payeur, J.B. | Saari, D.A. | Wilson, A.J. | Wolf, M.M.
A study to determine and compare the sensitivity of the caudal fold tuberculin test (CFT) and a commercial gamma-interferon (gamma-IFN) assay for diagnosis of bovine tuberculosis was conducted. A dairy herd with approximately a third of the cattle infected with Mycobacterium bovis was chosen for this study. All cattle from this herd were slaughtered, and tissue specimens for bacteriologic culturing and histologic examination were collected. Results of the CFT and gamma-IFN assay were compared with results of bacteriologic culturing and histologic examination to determine test sensitivity. Results were analyzed, using each of the following 4 standards to classify cattle as infected: positive test result by bacteriologic culturing only; histologic examination only; bacteriologic culturing and histologic examination; and bacteriologic culturing or histologic examination. Sensitivity of the CFT ranged from 80.4 to 84.4%, depending on the standard of comparison. Sensitivity of the gamma-IFN assay ranged from 55.4 to 97.1%, depending on the standard of comparison and on the method of interpretation. The CFT was significantly (P < 0.001) more sensitive than the gamma-IFN assay for diagnosis of bovine tuberculosis when the gamma-IFN assay was conducted and interpreted as instructed by the manufacturer. Maximum overall sensitivity was achieved when results of the CFT and gamma-IFN assay were interpreted in parallel.
Afficher plus [+] Moins [-]Magnetic resonance arthrography of the scapulohumeral joint in dogs, using gadopentetate dimeglumine
1995
Bree, H van | Ryssen, B. van | Degryse, H. | Ramon, F.
Six scapulohumeral joints (3 normal joints and 3 joints with radiographic evidence of osteochondrosis) underwent conventional magnetic resonance (MR) imaging and MR scapulohumeral arthrography to evaluate delineation of the articular cartilage. The MR arthrography was performed, using 5 ml of 500 micromolar gadopentetate dimeglumine (Gd-DTPA) as a contrast medium. Delineation of normal articular cartilage and cartilage defects was less accurate after intra-articular administration of Gd-DTPA. Therefore, it was concluded that MR arthrography with Gd-DTPA is unrewarding for evaluation of osteochondrosis lesions.
Afficher plus [+] Moins [-]Evaluation of an enzyme-linked immunosorbent assay for diagnosis of paratuberculosis in goats
1994
Burnside, D.M. | Rowley, B.O.
A commercial rapid-absorbed ELISA developed to detect antibodies to Mycobacterium paratuberculosis in bovine serum was modified for use with goat serum. Diagnostic sensitivity was evaluated, using a group of 163 goats from a herd with endemic paratuberculosis. Blood and fecal samples were obtained simultaneously, and prevalence of shedding of M paratuberculosis in the feces was estimated by detection of DNA of the mycobacterial insertion sequence, IS900, using a commercial test kit. Diagnostic specificity was evaluated, using blood samples from a total of 123 goats in 10 herds that were considered clinically free of paratuberculosis. The IS900 DNA was detected in 35 of the 163 goats (21%) from the infected herd. Serum antibody to M paratuberculosis was detected in 19 of the 35 IS900 DNA-positive goats, for apparent sensitivity of 54%. Serum antibody was detected in 18 of the 128 IS900 DNA-negative goats from the infected herd. Negative results for serum antibody to M paratuberculosis were obtained for all 123 goats from the herds that were considered clinically free of paratuberculosis.
Afficher plus [+] Moins [-]