Effects of the fraction of inspired oxygen on alfaxalone-sedated inland bearded dragons (Pogona vitticeps)
2019
Ratliff, Cameron | Parkinson, Lily A. B. | Mans, Christoph
OBJECTIVE To evaluate the effects of providing 100% O2, compared with provision of room air, in sedated spontaneously breathing inland bearded dragons (Pogona vitticeps). ANIMALS 8 adult bearded dragons. PROCEDURES Animals were sedated with alfaxalone (20 mg/kg, SC) and received 21% O2 (equivalent to room air) or 100% O2 via face mask (flow rate, 1 L/min) in a randomized, blinded, complete crossover study (2-week interval between treatments). Sedation variables, cardiopulmonary variables, venous blood gas values, and postsedation food intake were evaluated. RESULTS Respiratory rate, heart rate, oxygen saturation, and sedation quality were comparable between treatments. Venous blood gas analysis revealed a higher total Pco2 and HCO3− concentration for the 21% O2 treatment. Postsedation food intake was not affected by the inspired oxygen fraction provided during sedation. CONCLUSIONS AND CLINICAL RELEVANCE The fraction of inspired oxygen did not appear to have clinically relevant effects on physiologic variables of bearded dragons during and after sedation. Therefore, provision of 100% O2 can be considered for use in sedated bearded dragons without the risk of inducing hypoventilation. Similarly, failure to provide 100% O2 would be unlikely to result in clinically relevant consequences in healthy sedated bearded dragons.
Afficher plus [+] Moins [-]In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat
2019
McGlinchey, Leah | Munsterman, Amelia S. | Coleridge, Matthew O. D. | Rosanowski, Sarah M. | Farag, Ramsis | Hanson, R Reid
OBJECTIVE To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots. SAMPLE 315 knots tied and tested in vitro. PROCEDURES United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile strength of suture and knots to failure, and the KHC, RKS, weight, and volume of knots were determined. RESULTS Forwarder knots had significantly higher KHC and RKS and lower volume, compared with surgeons’ knots. Forwarder knots tied with fat-exposed suture had greater weight, but not volume, than did forwarder knots tied with dry or BES-exposed suture with the same number of throws. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that forwarder knots were superior to surgeon's knots when configured as start knots intended for continuous lines of suture. Exposure to media did not negatively affect mechanical or physical properties of forwarder knots and may improve specific biomechanical functions, including KHC and RKS.
Afficher plus [+] Moins [-]In vitro evaluation of negative pressure generated during application of negative suction volumes by use of various syringes with and without thoracostomy tubes
2019
Mezzles, Marguerite J. | Murray, Rebecca L. | Heiser, Brian P.
OBJECTIVE To determine the amount of negative pressure generated by syringes of various sizes with and without an attached thoracostomy tube and whether composition of thoracostomy tubes altered the negative pressure generated. SAMPLE Syringes ranging from 1 to 60 mL and 4 thoracostomy tubes of various compositions (1 red rubber catheter, 1 polyvinyl tube, and 2 silicone tubes). PROCEDURES A syringe or syringe with attached thoracostomy tube was connected to a pneumatic transducer. Each syringe was used to aspirate a volume of air 10 times. Negative pressure generated was measured and compared among the various syringe sizes and various thoracostomy tubes. RESULTS The negative pressure generated decreased as size of the syringe increased for a fixed volume across syringes. Addition of a thoracostomy tube further decreased the amount of negative pressure. The red rubber catheter resulted in the least amount of negative pressure, followed by the polyvinyl tube and then the silicone tubes. There was no significant difference in negative pressure between the 2 silicone tubes. The smallest amount of negative pressure generated was −74 to −83 mm Hg. CONCLUSIONS AND CLINICAL RELEVANCE Limited data are available on the negative pressure generated during intermittent evacuation of the thoracic cavity. For the present study, use of a syringe of ≥ 20 mL and application of 1 mL of negative suction volume resulted in in vitro pressures much more negative than the currently recommended pressure of −14.71 mm Hg for continuous suction. Additional in vitro or cadaveric studies are needed.