Affiner votre recherche
Résultats 1-2 de 2
Effect of screw position on single cycle to failure in bending and torsion of a locking plate–rod construct in a synthetic feline femoral gap model
2015
Niedehauser, Simone K. | Tepić, Slobodan | Weber, Urs T.
OBJECTIVE To evaluate the effect of screw position on strength and stiffness of a combination locking plate–rod construct in a synthetic feline femoral gap model. SAMPLE 30 synthetic long-bone models derived from beechwood and balsa wood. PROCEDURES 3 constructs (2 locking plate–rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. RESULTS Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate–rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.
Afficher plus [+] Moins [-]Critical response time (time available to implement effective measures for epidemic control): Model building and evaluation
2003
Rivas, A.L. | Tennenbaum, S.E. | Aparicio, J.P. | Hoogesteijn, A.L. | Mohammed, H.O. | Castillo-Chávez, C. | Schwager, S.J.
The time available to implement successful control measures against epidemics was estimated. Critical response time (CRT), defined as the time interval within which the number of epidemic cases remains stationary (so that interventions implemented within CRT may be the most effective or least costly), was assessed during the early epidemic phase, when the number of cases grows linearly over time. The CRT was calculated from data of the 2001 foot-and-mouth disease (FMD) epidemic that occurred in Uruguay. Significant regional CRT differences (ranging from 1.4 to 2.7 days) were observed. The CRT may facilitate selection of control measures. For instance, a CRT equal to 3 days would support the selection of measures, such as stamping-out, implementable within 3 days, but rule out measures, such as post-outbreak vaccination, because intervention and immunity building require more than 3 days. Its use in rapidly disseminating diseases, such as FMD, may result in regionalized decision-making.
Afficher plus [+] Moins [-]