Affiner votre recherche
Résultats 1-2 de 2
Effects of anesthesia with isoflurane on plasma concentrations of adrenocorticotropic hormone in samples obtained from the cavernous sinus and jugular vein of horses
2016
Carmalt, James L. | Duke-Novakovski, Tanya | Schott, Harold C II | Kolk, Johannes H van der
OBJECTIVE To determine effects of anesthesia on plasma concentrations and pulsatility of ACTH in samples obtained from the cavernous sinus and jugular vein of horses. ANIMALS 6 clinically normal adult horses. PROCEDURES Catheters were placed in a jugular vein and into the cavernous sinus via a superficial facial vein. The following morning (day 1), cavernous sinus blood samples were collected every 5 minutes for 1 hour (collection of first sample = time 0) and jugular venous blood samples were collected at 0, 30, and 60 minutes. On day 2, horses were sedated with xylazine hydrochloride and anesthesia was induced with propofol mixed with ketamine hydrochloride. Horses were positioned in dorsal recumbency. Anesthesia was maintained with isoflurane in oxygen and a continuous rate infusion of butorphanol tartrate. One hour after anesthesia was induced, the blood sample protocol was repeated. Plasma ACTH concentrations were quantified by use of a commercially available sandwich assay. Generalized estimating equations that controlled for horse and an expressly automated deconvolution algorithm were used to determine effects of anesthesia on plasma ACTH concentrations and pulsatility, respectively. RESULTS Anesthesia significantly reduced the plasma ACTH concentration in blood samples collected from the cavernous sinus. CONCLUSIONS AND CLINICAL RELEVANCE Mean plasma ACTH concentrations in samples collected from the cavernous sinus of anesthetized horses were reduced. Determining the success of partial ablation of the pituitary gland in situ for treatment of pituitary pars intermedia dysfunction may require that effects of anesthesia be included in interpretation of plasma ACTH concentrations in cavernous sinus blood.
Afficher plus [+] Moins [-]Two-dimensional left atrium–to–aorta ratios and left ventricular M-mode transthoracic echocardiographic measurements in clinically normal adult Dachshunds
2016
Lim, Chee Kin | Fosgate, Geoffrey T. | Green, Henry W III | Kirberger, Robert M.
OBJECTIVE To estimate the left atrium–to–aorta ratio (LA:Ao) and establish 95% prediction intervals for left ventricular M-mode transthoracic echocardiographic measurements in clinically normal adult Dachshunds. ANIMALS 40 healthy Dachshunds. PROCEDURES For each dog, 3 standard 2-D echocardiographic methods (diameter, circumference, and cross-sectional area) were used to measure the left atrium and aorta and calculate the LA:Ao from right parasternal short axis (RPSA) images obtained at the level of the aortic valve cusps. Left ventricular M-mode measurements were acquired from RPSA images obtained at the chordal level immediately below the mitral valve. Descriptive data were generated, and the 95% prediction intervals were calculated by use of an allometric scaling equation and linear regression and compared with those calculated on the basis of data obtained from dogs of multiple breeds in a previous study.RESULTS The mean (SD) LA:Ao was 1.40 (0.13), 2.09 (0.17), and 2.85 (0.48) for the diameter, circumference, and cross-sectional area methods, respectively. The 95% prediction intervals for the left ventricular M-mode measurements determined by an allometric scaling equation on the basis of Dachshund-specific data were narrower than those determined on the basis of data obtained from dogs of multiple breeds. For that allometric equation, scaling exponents on the basis of Dachshund-specific data ranged from 0.129 to 0.397 and did not absolutely conform to the presumed index for linear measurements (ie, body weight0.333). CONCLUSIONS AND CLINICAL RELEVANCE The LA:Aos and 95% prediction intervals calculated in this study can be used as preliminary guidelines for echocardiographic measurements of clinically normal Dachshunds.
Afficher plus [+] Moins [-]