Affiner votre recherche
Résultats 1-6 de 6
Epizootic and epidemiological situation of Trichinella sp. infection in Poland in 2006–2015 in view of wild boar population dynamics
2017
Flis, Marian | Grela, Eugeniusz R. | Gugała, Dariusz
Introduction: The objective was to evaluate the epizootic and epidemiological situation of Trichinella sp. infection in Poland between 2006 and 2015 against the dynamics of the wild boar population and its primary reservoir host.Material and Methods: Boar and porcine trichinosis epizootic analysis was based on General Veterinary Inspectorate data from RRW-6 bulletins. The epidemiological situation was evaluated on the basis of the data supplied by the Department of Epidemiology of the National Institute of Hygiene - National Institute of Public Health. The wild boar hunting harvest and population dynamics were estimated, as these animals remain the basic infection source for humans. Population size and harvest data were obtained from hunting statistics.Results: The study timeframe showed an almost 2.5-fold increase in Trichinella infection cases in wild boars but a significant decline in human cases. In the domestic pig, the incidence rate did not exceed 0.00037%. The highest infection risk exists in West Pomerania, Greater Poland, and Kuyavian-Pomeranian Provinces. Over the study period, the wild boar population increased more than 1.5-fold, while the hunting harvest more than tripled. During the last two seasons the total hunt surpassed 100% of the spring population.Conclusion: Wild boar management by increasing the hunting take of the annual population growth should limit that growth and decrease the take in the future. Thereby, over some years intra-species trichinosis spread should reduce, for a substantial safety gain for wild boar meat.
Afficher plus [+] Moins [-]Clostridium perfringens spores in Polish honey samples
2018
Grenda, Tomasz | Grabczak, Magdalena | Goldsztejn, Magdalena | Kozieł, Nina | Kwiatek, Krzysztof | Pohorecka, Krystyna | Skubida, Marta | Bober, Andrzej
The aim of this study was examination of honey samples collected from apiaries situated in all Polish provinces for occurrence of Clostridium spp., especially C. perfringens. The study was carried out on 240 honey samples (15 samples/province). Estimation of Clostridium titre, its cultures and C. perfringens isolate characterisation were performed according to the standard PN-R-64791:1994. A multiplex PCR method for detection of genes coding cpa (α toxin), cpb (β), cpb2 (β2), etx (ε), iap (ι), and cpe (enterotoxin) toxins was used. Clostridium spp. was noticed in 56% (136/240) of samples, and its titres ranged between 0.1 g and 0.001 g. Clostridium perfringens occurrence was evidenced in 27.5% (66/240) of samples. All isolates were classified to toxinotype A. Evidence of a high number of positive samples with occurrence of Clostridium spp. indicates a potential risk to consumers’ health. The infective number of Clostridium spp. is unknown; however, the obtained results have shown that a risk assessment on the entire honey harvesting process should be made in order to ensure microbiological safety. Moreover, a detailed study should be undertaken on the antibiotic resistance of C. perfringens isolates from honey samples.
Afficher plus [+] Moins [-]Performance of a gravitational marrow separator, multidirectional bone marrow aspiration needle, and repeated bone marrow collections on the production of concentrated bone marrow and separation of mesenchymal stem cells in horses
2013
Ishihara, Akikazu | Helbig, Holly J. | Sanchez-Hodge, Rebekah B. | Wellman, Maxey L. | Landrigan, Matthew D. | Bertone, Alicia L.
Objective-To determine the efficiency of a novel point-of-care gravitational marrow separator and bone marrow aspiration needle for concentrated bone marrow production and bone marrow-derived mesenchymal stem cell (MSC) separation and assess the effect of repeated bone marrow collections in horses. Animals-8 healthy adult horses. Procedures-Bone marrow aspiration was performed twice (1 month apart) from sternebral bodies with a standard or prototype multidirectional needle. Concentrated bone marrow was obtained by gravitational marrow separation and evaluated for WBC and platelet counts, automated and cytomorphologic cell differential counts, MSCs, and cell viability. Results-Concentrated bone marrow samples obtained with the marrow separator had 5- to 19-fold bone marrow-derived MSC, WBC, and platelet counts, compared with original bone marrow samples. Use of a multidirectional needle increased the frequency of obtaining MSC-richer concentrated bone marrow. Repeating bone marrow aspiration at 1 month yielded greater MSC numbers but slightly lower cell viability after processing. Conclusions and Clinical Relevance-The gravitational bone marrow separator and multidirectional needle were used to effectively harvest bone marrow and improve the quality of concentrated bone marrow. Comparable, or even greater, numbers of bone marrow-derived MSCs were collected by repeated bone marrow aspiration after a 1-month interval from the same aspiration sites. Use of the marrow separator and multidirectional bone marrow aspiration needle can facilitate a 1-step, point-of-care, nonlaboratory method to obtain concentrated bone marrow as a mixture of bone marrow-derived MSCs and growth factors from platelets and plasma.
Afficher plus [+] Moins [-]Perfusion method for harvesting bone marrow cells from dogs
2011
Satō, Masahiko | Goto-Koshino, Yuko | Mochizuki, Hiroyuki | Fujino, Yasuhito | Ohno, Koichi | Tsujimoto, Hajime
Objective—To compare composition and colony formation of bone marrow mononuclear cells (BMMCs) harvested from dogs by means of a new perfusion method and the conventional aspiration method. Animals—7 healthy adult Beagles. Procedures—BMMCs were collected from the humeri and femurs of Beagles via perfusion and aspiration methods. Flow cytometric analysis was performed to quantify the presence of contaminant cells from the peripheral blood and the percentage of CD34+ progenitor cells in the BMMCs. A CFU assay was conducted to determine the number of progenitor cells in the BMMCs. Results—The perfusion method was safely performed in all 7 dogs. Flow cytometric analysis revealed that the percentages of contaminant CD3+CD4+, CD3+CD8+, and CD21 + lymphocytes in BMMCs obtained via perfusion were significantly lower than percentages obtained via aspiration. The percentage of CD34+ cells obtained via perfusion was significantly higher than that obtained via aspiration. In addition, perfusion yielded a significantly higher CFU count than did aspiration. Conclusions and Clinical Relevance—The perfusion method used in this study can minimize the contamination of bone marrow samples with peripheral blood and was a more efficient means for collecting canine bone marrow progenitor cells than the conventional aspiration method. Therefore, the perfusion method can be more suitable than aspiration for harvesting bone marrow cells for transplantation in dogs.
Afficher plus [+] Moins [-]Sensory nerve conduction and nociception in the equine lower forelimb during perineural bupivacaine infusion along the palmar nerves
2010
The purpose of this investigation was to study lateral palmar nerve (LPN) and medial palmar nerve (MPN) morphology and determine nociception and sensory nerve conduction velocity (SNCV) following placement of continuous peripheral nerve block (CPNB) catheters along LPN and MPN with subsequent bupivacaine (BUP) infusion. Myelinated nerve fiber distribution in LPN and MPN was examined after harvesting nerve specimens in 3 anesthetized horses and processing them for morphometric analysis. In 5 sedated horses, CPNB catheters were placed along each PN in both forelimbs. Horses then received in one forelimb 3 mL 0.125% BUP containing epinephrine 1:200 000 and 0.04% NaHCO3 per catheter site followed by 2 mL/h infusion over a 6-day period, while in the other forelimb equal amounts of saline (SAL) solution were administered. The hoof withdrawal response (HWR) threshold during pressure loading of the area above the dorsal coronary band was determined daily in both forelimbs. On day 6 SNCV was measured under general anesthesia of horses in each limb’s LPN and MPN to detect nerve injury, followed by CPNB catheter removal. The SNCV was also recorded in 2 anesthetized non-instrumented horses (sham controls). In both LPN and MPN myelinated fiber distributions were bimodal. The fraction of large fibers (>7 μm) was greater in the MPN than LPN (P < 0.05). Presence of CPNB catheters and SAL administration did neither affect measured HWR thresholds nor SNCVs, whereas BUP infusion suppressed HWRs. In conclusion, CPNB with 0.125% BUP provides pronounced analgesia by inhibiting sensory nerve conduction in the distal equine forelimb.
Afficher plus [+] Moins [-]Comparison of glucose concentrations in serum, plasma, and blood measured by a point-of-care glucometer with serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples
2019
Lechner, Matthew J. | Hess, Rebecka S.
OBJECTIVE To determine the correlation between glucose concentrations in serum, plasma, and blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by an automated biochemical analyzer (ABA; gold standard). SAMPLE 152 canine and 111 feline blood samples. PROCEDURES For each sample, the glucose concentration in serum, plasma, and blood was measured by a POCG and compared with the ABA-measured glucose concentration by means of the Lin concordance correlation coefficient. Results were summarized by species for all samples and subsets of samples with hyperglycemia (ABA-measured glucose concentration > 112 mg/dL for dogs and > 168 mg/dL for cats) and pronounced hyperglycemia (ABA-measured glucose concentration > 250 mg/dL for both species). The effect of PCV on correlations between POCG and ABA measurements was also assessed. RESULTS Hyperglycemia and pronounced hyperglycemia were identified in 69 and 36 canine samples and 44 and 29 feline samples, respectively. The POCG-measured glucose concentrations in serum, plasma, and blood were strongly and positively correlated with the gold standard concentration. The PCV was positively associated with the correlation between the POCG-measured blood glucose concentration and the gold standard concentration but was not associated with the correlations between the POCG-measured glucose concentrations in serum and plasma and the gold standard concentration. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that POCG-measured glucose concentrations in serum, plasma, and blood were strongly correlated with the ABA-measured serum glucose concentration, even in hyperglycemic samples. Given the time and labor required to harvest serum or plasma from blood samples, we concluded that blood was the preferred sample type for use with this POCG.
Afficher plus [+] Moins [-]