Affiner votre recherche
Résultats 1-6 de 6
Accuracy of pulse oximetry and capnography in healthy and compromised horses during spontaneous and controlled ventilation
2003
Koenig, Judith | McDonell, Wayne | Valverde, Alex
The objective of this prospective clinical study was to evaluate the accuracy of pulse oximetry and capnography in healthy and compromised horses during general anesthesia with spontaneous and controlled ventilation. Horses anesthetized in a dorsal recumbency position for arthroscopy (n = 20) or colic surgery (n = 16) were instrumented with an earlobe probe from the pulse oximeter positioned on the tip of the tongue and a sample line inserted at the Y-piece for capnography. The horses were allowed to breathe spontaneously (SV) for the first 20 min after induction, and thereafter ventilation was controlled (IPPV). Arterial blood, for blood gas analysis, was drawn 20 min after induction and 20 min after IPPV was started. Relationships between oxygen saturation as determined by pulse oximetry (SpO2), arterial oxygen saturation (SaO2), arterial carbon dioxide partial pressure (PaCO2), and end tidal carbon dioxide (P(et)CO2), several physiological variables, and the accuracy of pulse oximetry and capnography, were evaluated by Bland–Altman or regression analysis. In the present study, both SpO2 and P(et)CO2 provided a relatively poor indication of SaO2 and PaCO2, respectively, in both healthy and compromised horses, especially during SV. A difference in heart rate obtained by pulse oximetry, ECG, or palpation is significantly correlated with any pulse oximeter inaccuracy. If blood gas analysis is not available, ventilation to P(et)CO2 of 35 to 45 mmHg should maintain the PaCO2 within a normal range. However, especially in compromised horses, it should never substitute blood gas analysis.
Afficher plus [+] Moins [-]Changes in heart rate variability in horses during immersion in warm springwater
2003
Kato, Tomohiro | Ohmura, Hajime | Hiraga, Atsushi | Wada, Shinya | Kuwahara, Masayoshi | Tsubone, Hirokazu
Objective-To determine the effects of immersion in warm springwater (38° to 40°C) on autonomic nervous activity in horses. Animals-10 male Thoroughbreds. Procedure-Electrocardiograms were recorded from horses for 15 minutes during a warm springwater bath after being recorded for 15 minutes during stall rest. Variations in heart rate (HR) were evaluated from the power spectrum in terms of low frequency (LF, 0.01 to 0.07 Hz) power and high frequency (HF, 0.07 to 0.6 Hz) power as indices of autonomic nervous activity. Results-Mean (+/-SE) HR during stall rest and immersion in warm springwater was 31.1 +/- 1.7 and 30.3 +/- 1.0 beat/min, respectively. No significant difference was found between the HR recorded during stall rest and that recorded during immersion in warm springwater. The HF power significantly increased from 1,361 +/- 466 milliseconds2 during stall rest to 2,344 +/- 720 milliseconds2 during immersion in warm springwater. The LF power during stall rest and immersion in warm springwater was 3,847 +/- 663 and 5,120 +/- 1,094 milliseconds2, respectively, and were not significantly different from each other. Similarly, the LF:HF ratio did not change during immersion in warm springwater. The frequency of second-degree atrioventricular block, which was observed in 2 horses, increased during immersion in warm springwater, compared with during stall rest. Conclusions and Clinical Relevance-Increases in HF power indicates that the parasympathetic nervous activity in horses increases during immersion in warm springwater. Thus, immersion in warm springwater may provide a means of relaxation for horses.
Afficher plus [+] Moins [-]Do Thoroughbred and Standardbred horses have similar increases in pulmonary vascular pressures during exertion
2003
Hackett, R.P. | Ducharme, N.G. | Gleed, R.D. | Mitchell, L. | Soderholm, L.V. | Erickson, B.K. | Erb, H.N.
To test the hypothesis that the pulmonary vascular pressures of Thoroughbred and Standardbred horses behave similarly during exertion. Measurements were made on 5 Thoroughbred and 5 Standardbred horses on a treadmill at rest and during 3-minute exercise intervals at speeds predicted to produce 75%, 90%, and 100% maximal heart rate. Left forelimb acceleration, heart rate, esophageal pressure, and pulmonary artery pressure were measured continuously. Pulmonary capillary and wedge pressures were measured during intermittent occlusion of the pulmonary artery. Breathing rate and gait frequency were the fundamental frequencies of the esophageal pressure and limb acceleration signals respectively. The ratio of speed:gait frequency gave stride length. The effects of exertion and breed were evaluated using two-way analysis of variance. Exertion produced significant increases in pulmonary artery (P = 0.001), capillary (P= 0.002), and wedge (P= 0.005) pressures. No significant effect of breed was detected on pulmonary artery pressure, but at exertion pulmonary capillary and wedge pressures were 15% (P= 0.03) and 23% (P= 0.04) greater in Thoroughbreds, respectively. Treadmill speed was ~12% greater (P= 0.04), stride length was ~25% greater (P= 0.0003), gait frequency was ~10% less (P= 0.006), breathing rate was ~10% less (P= 0.001), and heart rate was ~6% less (P= 0.06) for Thoroughbreds. There was no effect of breed on inspiratory or expiratory esophageal pressure although mean esophageal pressure was ~2 mmHg greater (P= 0.03) in exercising Standardbreds. In conclusion, pulmonary capillary and wedge pressures are greater in Thoroughbreds than in Standardbreds at similar fractions of maximal heart rate. This is compatible with the higher incidence of exercise-induced pulmonary hemorrhage observed in Thoroughbreds.
Afficher plus [+] Moins [-]Evaluation of transcutaneous Doppler ultrasonography for the measurement of blood flow in the femoral artery of pigs
2003
Fernández del Palacio, Maria Josefa | Luis Fuentes, Virginia | Bonagura, John D. | Schober, Karsten E. | Hatfield, Daniel G. | Laughlin, Harold M.
Objective-To compare measurements of blood flow in the common femoral artery obtained by duplex Doppler ultrasonography (DDU) and a reference ultrasonic transit-time flow (TTF) method and to examine the impact of Doppler spectral waveform measurement techniques on volumetric estimates. Animals-5 healthy female pigs. Procedure-Femoral arterial blood flow was measured simultaneously in anesthetized pigs by use of a TTF probe (left femoral artery) and transcutaneous DDU (right femoral artery). A range of flow states was induced pharmacologically by using xylazine, bradykinin, dobutamine, and isoflurane. Volumetric blood flow was calculated from DDU waveforms, using the product of the flow velocity integral (FVI), the cross-sectional vessel area, and heart rate. Three calculations of FVI were obtained by manually tracing the Doppler spectral envelopes at the outer envelope, the modal, and the inner envelope of the spectral dispersion pattern. Data analysis included calculation of Pearson correlation coefficients and Bland-Altman limits of agreement. Results-Blood flow measured by DDU was more closely correlated with TTF measurements when the modal or inner envelope tracing method was used ( r, 0.76 and 0.78; limits of agreement, -100 to 54.2 and -48.5 to 77.0 mL/min, respectively). Limits of agreement for the outer envelope tracing method were -238.5 to 64 mL/min. Conclusion and Clinical Relevance-Transcutaneous DDU is a reliable noninvasive technique for measuring blood flow in the femoral artery of pigs over a range of flow states. Tracing the inner envelope of the Doppler spectral dispersion pattern provided the best estimate of blood flow in this study.
Afficher plus [+] Moins [-]Spectral analysis of heart rate variability in dogs with mild mitral regurgitation
2003
Fujii, Yoko | Wakao, Yoshito
Objective-To assess autonomic function in dogs with mild mitral regurgitation (MR) that did not have clinical signs of the condition. Animals-6 healthy adult Beagles. Procedure-Mild MR was experimentally induced. A 24-hour ambulatory ECG was recorded before and after induction of MR. Heart rate variability was analyzed in frequency domains by use of the ambulatory ECG. Low-frequency (LF) and high-frequency (HF) power were calculated by integrating over their frequency intervals, and the ratio of LF to HF was also calculated. Measurements of frequency domains were analyzed for 4 time periods (midnight to 6 AM, 6 AM to noon, noon to 6 PM, and 6 PM to midnight). Results-Dogs with experimentally induced MR were classified as International Small Animal Cardiac Health Council class Ia. The HF power of dogs with MR was significantly decreased between 6 AM and noon. The ratio of LF to HF in dogs with MR was significantly increased for the periods between midnight and 6 AM, 6 AM and noon, and noon and 6 PM. Conclusions and Clinical Relevance-Compensatory response through autonomic modulation was observed in dogs with mild MR that did not have abnormalities, except for cardiac murmur, during clinical examination. This result suggests that treatment during the early stages of mild MR may be beneficial. Additional studies are necessary to determine whether such treatment will delay the onset of congestive heart failure and prolong survival in dogs affected with mild MR.
Afficher plus [+] Moins [-]Analgesic and systemic effects of ketamine, xylazine, and lidocaine after subarachnoid administration in goats
2003
DeRossi, Rafael | Junqueira, Alexandre Lopes | Beretta, Marcelo Paixão
Objective-To determine the effects of ketamine hydrochloride, xylazine hydrochloride, and lidocaine hydrochloride after subarachnoid administration in goats. Animals-6 healthy goats. Procedure-In each goat, ketamine (3 mg/kg), xylazine (0.1 mg/kg), lidocaine (2.5 mg/kg), and saline (0.9% NaCl) solution were injected into the subarachnoid space between the last lumbar vertebra and first sacral vertebra (time 0). Analgesic, ataxic, sedative, cardiovascular, and respiratory effects and rectal temperature were evaluated before (baseline) and 2, 5, 10, 15, and 30 minutes after administration and at 30-minute intervals thereafter as needed. Results-Administration of anesthetics induced varying degrees of analgesia. Onset of the analgesic effect was more delayed for xylazine (mean +/- SD, 9.5 +/- 2.6 minutes) than for ketamine (6.7 +/- 2.6 minutes) or lidocaine (3.5 +/- 1.2 minutes). Duration of analgesia induced by xylazine (88.3 ± 15 minutes) was twice as long as the duration of analgesia induced by ketamine (48.8 ± 13.5 minutes) but similar to that induced by lidocaine (66.5 ± 31 minutes). Xylazine induced bradycardia, whereas ketamine caused a nonsignificant increase in heart rate. Xylazine induced a reduction in arterial pressure, whereas ketamine or lidocaine did not affect arterial pressure. Conclusion and Clinical Relevance-Subarachnoid administration of xylazine in goats resulted in longer duration of analgesia of the tail, perineum, hind limbs, flanks, and caudodorsal rib areas than administration of ketamine or lidocaine. However, xylazine caused bradycardia and respiratory depression. Additional studies are needed to determine whether the analgesia would be sufficient to allow clinicians to perform surgical procedures.
Afficher plus [+] Moins [-]