Affiner votre recherche
Résultats 1-9 de 9
Effect of omega-3 fatty acids on serum concentrations of adipokines in healthy cats
2011
Mazaki-Tovi, Michal | Abood, Sarah K. | Schenck, Patricia A.
Objective: To determine associations between serum concentrations of omega-3 polyunsaturated fatty acids and concentrations of adiponectin, leptin, and insulin in healthy cats. Animals: 56 healthy adult client-owned cats. Procedures: Body condition score (BCS) was determined, and blood samples were collected after food was withheld for 12 hours. Serum was harvested for fatty acid analysis and measurement of serum concentrations of adiponectin, leptin, insulin, glucose, triglyceride, and cholesterol. Results: 1 cat was removed because of hyperglycemia. Significant interaction effects between BCS and serum concentrations of eicosapentaenoic acid (EPA) were detected for the analyses of associations between EPA and serum concentrations of adiponectin, insulin, and triglyceride. Cats were categorized into nonobese (BCS, 4 to 6 [n = 34 cats]) and obese (BCS, 7 to 8 [21]) groups; serum concentrations of EPA were directly associated with concentrations of adiponectin and inversely associated with concentrations of insulin and triglyceride in obese cats and were directly associated with concentrations of leptin and inversely associated with concentrations of adiponectin in nonobese cats. Additionally, serum concentrations of docosahexaenoic acid were directly associated with concentrations of adiponectin in obese cats. No significant associations between serum concentrations of docosahexaenoic acid or α-linolenic acid were detected in the analyses for all cats. Female cats had higher serum concentrations of adiponectin and lower concentrations of glucose than did male cats. Increased age was associated with a small increase in serum concentrations of leptin. Conclusions and Clinical Relevance: EPA may ameliorate the decrease in adiponectin and the increase in insulin and triglyceride concentrations in obese cats.
Afficher plus [+] Moins [-]Hemodynamic effects of methylprednisolone acetate administration in cats
2006
Ployngam, T. | Tobias, A.H. | Smith, S.A. | Torres, S.M.F. | Ross, S.J.
Objective-To investigate the mechanisms by which corticosteroid administration may predispose cats to congestive heart failure (CHF). Animals-12 cats receiving methylprednisolone acetate (MPA) for the treatment of dermatologic disorders. Procedure-The study was conducted as a repeated-measures design. Various baseline variables were measured, after which MPA (5 mg/kg, IM) was administered. The same variables were then measured at 3 to 6 days and at 16 to 24 days after MPA administration. Evaluations included physical examination, systolic blood pressure measurement, hematologic analysis, serum biochemical analysis, thoracic radiography, echocardiography, and total body water and plasma volume determination. Results-MPA resulted in a substantial increase in serum glucose concentration at 3 to 6 days after administration. Concurrently, RBC count, Hct, and hemoglobin concentration as well as serum concentrations of the major extracellular electrolytes, sodium and chloride, decreased. Plasma volume increased by 13.4% (> 40% in 3 cats), whereas total body water and body weight slightly decreased. All variables returned to baseline by 16 to 24 days after MPA administration. Conclusions and Clinical Relevance-These data suggest that MPA administration in cats causes plasma volume expansion as a result of an intra- to extracellular fluid shift secondary to glucocorticoid-mediated extracellular hyperglycemia. This mechanism is analogous to the plasma volume expansion that accompanies uncontrolled diabetes mellitus in humans. Any cardiovascular disorders that impair the normal compensatory mechanisms for increased plasma volume may predispose cats to CHF following MPA administration.
Afficher plus [+] Moins [-]Evaluation of subcutaneously administered electrolyte solutions in experimentally dehydrated inland bearded dragons (Pogona vitticeps)
2020
Parkinson, Lily A. | Mans, Christoph
OBJECTIVE To evaluate the effects of 3 electrolyte solutions administered SC to experimentally dehydrated inland bearded dragons (Pogona vitticeps). ANIMALS 9 inland bearded dragons. PROCEDURES In a randomized, complete crossover study, experimental dehydration was induced by means of furosemide (10 mg/kg, SC, q 12 h for 4 doses), and then lactated Ringer solution, Plasma-Lyte A, or reptile Ringer solution (RRS; 1:1 mixture of 5% dextrose solution and isotonic crystalloid solution) was administered SC in a single 50-mL/kg dose in 3 treatments sessions separated by a minimum of 14 days. Food and water were withheld during treatment sessions. Plasma biochemical values, PCV, blood total solids and lactate concentrations, and plasma osmolarity were measured prior to (baseline) and 4 and 24 hours after fluid administration. RESULTS Administration of RRS resulted in severe hyperglycemia (mean ± SD plasma glucose concentration, 420 ± 62 mg/dL), compared with baseline values (190 ± 32 mg/dL), and this hyperglycemia persisted for at least 24 hours. It also resulted in significant reductions in plasma osmolarity and sodium and phosphorus concentrations, which were not observed after administration of the other 2 solutions. Administration of lactated Ringer solution caused no significant increase in blood lactate concentration. CONCLUSIONS AND CLINICAL RELEVANCE The changes in plasma glucose, sodium, and phosphorus concentrations and plasma osmolarity observed after SC administration of a single dose of RRS suggested this type of electrolyte solution should not be used for rehydration of bearded dragons. Rather, lactated Ringer solution or Plasma-Lyte A should be considered instead.
Afficher plus [+] Moins [-]Effects of treatment with lispro and neutral protamine Hagedorn insulins on serum fructosamine and postprandial blood glucose concentrations in dogs with clinically well-controlled diabetes mellitus and postprandial hyperglycemia
2020
Bertalan, Abigail V. | Drobatz, Kenneth J. | Hess, Rebecka S.
OBJECTIVE To assess effects of basal-bolus insulin treatment (BBIT) with lispro and neutral protamine Hagedorn (NPH) insulins, compared with NPH insulin alone, on serum fructosamine concentration (SFC) and postprandial blood glucose concentration (BGC) in dogs with clinically well-controlled diabetes mellitus and postprandial hyperglycemia fed a high insoluble fiber–content diet. ANIMALS 6 client-owned dogs with diabetes mellitus. PROCEDURES Blood samples were collected for BGC and SFC measurement in hospitalized dogs just before feeding and routine SC NPH insulin administration (time 0); samples were collected for BGC measurement every 30 minutes for 2 hours, then every 2 hours for up to 10 additional hours. Postprandial hyperglycemia was identified when BGC 30 minutes after insulin administration exceeded BGC at time 0 or the 1-hour time point. For BBIT, owners were instructed to continue NPH insulin administration at the usual dosage at home (q 12 h, with feeding) and to administer lispro insulin (0.1 U/Kg, SC) separately at the time of NPH injections. Two weeks later, SFC and BGC measurements were repeated; results at the start and end of the study were compared statistically. RESULTS Median SFC was significantly higher at the start (400 μmol/L) than at the end (390 μmol/L) of the study. Median 1-hour (313 mg/dL) and 1.5-hour (239 mg/dL) BGC measurements at the start of the study were significantly higher than those at the end of the study (117 and 94 mg/dL, respectively). CONCLUSIONS AND CLINICAL RELEVANCE In this sample of dogs with well-controlled diabetes mellitus, addition of lispro insulin to an existing treatment regimen of NPH insulin and dietary management significantly decreased postprandial BGCs. Further study of BBIT for dogs with diabetes mellitus is warranted.
Afficher plus [+] Moins [-]Comparison of glucose concentrations in serum, plasma, and blood measured by a point-of-care glucometer with serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples
2019
Lechner, Matthew J. | Hess, Rebecka S.
OBJECTIVE To determine the correlation between glucose concentrations in serum, plasma, and blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by an automated biochemical analyzer (ABA; gold standard). SAMPLE 152 canine and 111 feline blood samples. PROCEDURES For each sample, the glucose concentration in serum, plasma, and blood was measured by a POCG and compared with the ABA-measured glucose concentration by means of the Lin concordance correlation coefficient. Results were summarized by species for all samples and subsets of samples with hyperglycemia (ABA-measured glucose concentration > 112 mg/dL for dogs and > 168 mg/dL for cats) and pronounced hyperglycemia (ABA-measured glucose concentration > 250 mg/dL for both species). The effect of PCV on correlations between POCG and ABA measurements was also assessed. RESULTS Hyperglycemia and pronounced hyperglycemia were identified in 69 and 36 canine samples and 44 and 29 feline samples, respectively. The POCG-measured glucose concentrations in serum, plasma, and blood were strongly and positively correlated with the gold standard concentration. The PCV was positively associated with the correlation between the POCG-measured blood glucose concentration and the gold standard concentration but was not associated with the correlations between the POCG-measured glucose concentrations in serum and plasma and the gold standard concentration. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that POCG-measured glucose concentrations in serum, plasma, and blood were strongly correlated with the ABA-measured serum glucose concentration, even in hyperglycemic samples. Given the time and labor required to harvest serum or plasma from blood samples, we concluded that blood was the preferred sample type for use with this POCG.
Afficher plus [+] Moins [-]Evaluation of tissue Doppler ultrasonographic and strain imaging for assessment of myocardial dysfunction in dogs with type 1 diabetes mellitus
2018
Kim, Yun-Hye | Kim, Jung-Hyun | Park, Chul
OBJECTIVE To investigate cardiac structural and functional changes by tissue Doppler imaging (TDI) and strain imaging in dogs with spontaneous type 1 diabetes mellitus. ANIMALS 30 client-owned dogs, of which 10 had normotensive type 1 diabetes mellitus and 20 were healthy. PROCEDURES All dogs underwent physical examination, laboratory analyses, standard echocardiography, and TDI. RESULTS On TDI and strain imaging, transmitral peak early diastolic velocity (E)-to-tissue Doppler–derived peak early diastolic velocity at basal segment (E') of septum ratio, E:lateral E’ ratio, and septal tissue Doppler–derived peak late diastolic velocity at basal segment (A') were significantly higher and the septal E':A’ ratio and lateral longitudinal strain were significantly lower for diabetic dogs than for control dogs. Furthermore, in diabetic dogs, serum glucose and fructosamine concentrations after a 12-hour period of food withholding were positively correlated with regional systolic functional variables (septal and lateral longitudinal strain) and left ventricular filling pressure indices (E:septal E’ and E:lateral E’ ratios) but were negatively correlated with diastolic functional variables (E:transmitral peak late diastolic velocity and septal and lateral E':A’ ratios). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that myocardial function in diabetic dogs may be altered before the development of clinical heart-associated signs and that the change may be more readily detected by TDI and strain imaging than by conventional echocardiography. In addition, findings indicated that hyperglycemia could have detrimental effects on myocardial function, independent of hypertension, other cardiac diseases, and left ventricular hypertrophy, in dogs with type 1 diabetes.
Afficher plus [+] Moins [-]Effects of intramuscular administration of tiletamine-zolazepam with and without sedative pretreatment on plasma and serum biochemical values and glucose tolerance test results in Japanese black bears (Ursus thibetanus japonicus)
2012
Objective: To establish a safe anesthetic protocol with little effect on blood biochemical values and IV glucose tolerance test (IVGTT) results in Japanese black bears (Ursus thibetanus japonicus). Animals: 16 captive female Japanese black bears (5 to 17 years of age). Procedures: Bears were randomly assigned to 4 treatment groups (4 bears/group) in which various treatment combinations were administered via blow dart: tiletamine HCl and zolazepam HCl (9 mg/kg) alone (TZ), TZ (6 mg/kg) and acepromazine maleate (0.1 mg/kg), TZ (6 mg/kg) and butorphanol tartrate (0.3 mg/kg), or TZ (3 mg/kg) and medetomidine HCl (40 μg/kg). Glucose injection for the IVGTT was started 130 minutes after TZ administration. Blood samples were obtained before, at, and intermittently after glucose injection for measurement of biochemical variables as well as plasma glucose and serum insulin concentrations during the IVGTT. Rectal temperature, pulse rate, and respiratory rate were assessed every 15 minutes during the experiment. Results: Induction and maintenance of anesthesia were safely achieved with little adverse effect on cardiopulmonary function when each of the 4 anesthetic regimens was used, although mild hypothermia was induced. No difference was evident between treatment groups in blood biochemical values. Blood glucose and insulin concentration profiles during the IVGTT were similar among the bears given TZ, with or without acepromazine or butorphanol, but hyperglycemia and hypoinsulinemia developed in bears given TZ with medetomidine. Conclusions and Clinical Relevance: All 4 anesthetic regimens yielded chemical restraint without affecting clinical and biochemical values in bears, but medetomidine appeared to affect IVGTT results. For this reason, medetomidine should not be used when anesthetizing bears for IVGTTs.
Afficher plus [+] Moins [-]Administration of total parenteral nutrition in pigeons
1994
Degernes, L. | Davidson, G. | Flammer, K. | Kolmstetter, C. | Munger, L.
Venous access devices connected to jugular vein catheters were implanted SC in 2 groups of 6 White Carneau pigeons (Columba livia). Total parenteral nutrition (TPN), or a control solution (lactated Ringer's solution) was infused as a bolus 4 times daily. Physiologic, hematologic, and biochemical variables were monitored over 5 days. Complications in the TPN-treated pigeons included 8.7% weight loss during the 5-day trial, hyperglycemia for up to 90 minutes after infusion, and glucosuria after infusion. Control pigeons lost 1.3% of their body weight and did not become hyperglycemic or glucosuric after infusion. Hematocrit in both groups of pigeons decreased to a value slightly below published reference values for pigeons. Five pigeons developed venous thrombosis in the proximal part of the cranial vena cava. Results indicated that intermittent administration of TPN is possible in birds; however, further research is required to develop better techniques for administration of TPN solutions. Additionally, it is important to determine, more specifically, the caloric and nutrient requirements of pigeons under stress and receiving TPN.
Afficher plus [+] Moins [-]Effect of sensor location in dogs on performance of an interstitial glucose monitor
2016
Koenig, Amie | Hoenig, Margarethe E. | Jimenez, David A.
OBJECTIVE To identify variations in glucose values concurrently obtained by use of a continuous glucose monitoring system (CGMS) at the same site, reliability of results for each site, lag time for each site, and influence of site thickness on CGMS accuracy. ANIMALS 8 random-source research dogs. PROCEDURES In experiment 1, 8 CGMS sensors were implanted bilaterally at 1 site (4 sensors/side) in 4 dogs. In experiment 2, 2 CGMS sensors were implanted bilaterally at each of 4 sites (1 sensor/side) in 8 dogs; 4 of those 8 dogs then were subjected to a glycemic clamp technique. The CGMS results were compared among sensors and with criterion-referenced results during periods of euglycemia for all 8 dogs and during hyperglycemia and hypoglycemia for 4 dogs during the glycemic clamp procedure. RESULTS Differences (median, −7 mg/dL; interquartile range [IQR], −18.75 to 3 mg/dL) between CGMS and criterion-referenced glucose concentrations differed significantly among dogs and sites; during euglycemia, they were not different from the expected normal variation between multiple sensors concurrently implanted at the same site. Differences (median, −35 mg/dL; IQR, −74 to −15 mg/dL) between CGMS and criterion-referenced concentrations were greater during changes in glucose concentrations. Thoracic sensors were most accurate but had the shortest mean functional life. CONCLUSIONS AND CLINICAL RELEVANCE Significant differences were detected between CGMS and criterion-referenced glucose concentrations. Overall clinical utility of CGMS was acceptable at all sites, with most of the values from all sensors, sites, and dogs meeting guidelines for point-of-care glucometers.
Afficher plus [+] Moins [-]