Affiner votre recherche
Résultats 1-7 de 7
Assessment of blood pool, soft tissue, and skeletal uptake of sodium fluoride F 18 with positron emission tomography–computed tomography in four clinically normal dogs
2012
Valdés-Martínez, Alejandro | Kraft, Susan L. | Brundage, Cord M. | Arceneaux, Billie K. | Stewart, Jeffrey A. | Gibbons, Debra S.
Objective: To determine the ideal interval to image acquisition after IV injection of sodium fluoride F 18 (18F-NaF) and evaluate biodistribution of the radiopharmaceutical in clinically normal skeletally immature dogs. Animals: 4 female dogs. Procedures: Each dog was anesthetized for evaluation with a commercial hybrid positron emission tomography (PET)–CT instrument. A low–radiation dose, whole-body CT scan was acquired first. An IV injection of 18F-NaF (0.14 mCi/kg) was administered, and a dynamic PET scan centered over the heart and liver was acquired during a period of 120 minutes. Uptake of 18F-NaF in the blood pool, soft tissues, and skeletal structures was evaluated via region of interest analysis to derive standardized uptake values and time-activity curves, which were used to determine the optimal postinjection time for skeletal image acquisition. Biodistribution was also assessed from a final whole-body PET-CT scan acquired after the dynamic scan. Results: Time-activity curves revealed a rapid decrease in the amount of radiopharmaceutical in the blood pool and soft tissues and a rapid increase in the amount of radiopharmaceutical in bones soon after injection. At 50 minutes after injection, the greatest difference in uptake between soft tissues and bones was detected, with continued subtle increase in uptake in the bones. Uptake of 18F-NaF was slightly increased at growth plates and open ossification centers, compared with that at other parts of the bone. Conclusions and Clinical Relevance: At 50 minutes after IV injection of 18F-NaF at the dose evaluated, PET-CT yielded excellent bone-to-background ratio images for evaluation of the skeletal system in dogs.
Afficher plus [+] Moins [-]Comparison of transcoelomic, contrast transcoelomic, and transesophageal echocardiography in anesthetized red-tailed hawks (Buteo jamaicensis)
2012
Beaufrere, Hugues | Pariaut, Romain | Rodríguez, Daniel | Nevarez, Javier G. | Tully, Thomas N.
Objective: To assess the agreement and reliability of cardiac measurements obtained with 3 echocardiographic techniques in anesthetized red-tailed hawks (Buteo jamaicensis). Animals: 10 red-tailed hawks. Procedures: Transcoelomic, contrast transcoelomic, and transesophageal echocardiographic evaluations of the hawks were performed, and cineloops of imaging planes were recorded. Three observers performed echocardiographic measurements of cardiac variables 3 times on 3 days. The order in which hawks were assessed and echocardiographic techniques were used was randomized. Results were analyzed with linear mixed modeling, agreement was assessed with intraclass correlation coefficients, and variation was estimated with coefficients of variation. Results: Significant differences were evident among the 3 echocardiographic methods for most measurements, and the agreement among findings was generally low. Interobserver agreement was generally low to medium. Intraobserver agreement was generally medium to high. Overall, better agreement was achieved for the left ventricular measurements and for the transesophageal approach than for other measurements and techniques. Conclusions and Clinical Relevance: Echocardiographic measurements in hawks were not reliable, except when the left ventricle was measured by the same observer. Furthermore, cardiac morphometric measurements may not be clinically important. When measurements are required, one needs to consider that follow-up measurements should be performed by the same echocardiographer and should show at least a 20% difference from initial measurements to be confident that any difference is genuine.
Afficher plus [+] Moins [-]Development of a technique for contrast radiographic examination of the gastrointestinal tract in ball pythons (Python regius)
2012
Banzato, Tommaso | Russo, Elisa | Finotti, Luca | Zotti, Alessandro
Objective: To develop a technique for radiographic evaluation of the gastrointestinal tract in ball pythons (Python regius). Samples: 10 ball python cadavers (5 males and 5 females) and 18 healthy adult ball pythons (10 males and 8 females). Procedures: Live snakes were allocated to 3 groups (A, B, and C). A dose (25 mL/kg) of barium sulfate suspension at 3 concentrations (25%, 35%, and 45% [wt/vol]) was administered through an esophageal probe to snakes in groups A, B, and C, respectively. Each evaluation ended when all the contrast medium had reached the large intestine. Transit times through the esophagus, stomach, and small intestine were recorded. Imaging quality was evaluated by 3 investigators who assigned a grading score on the basis of predetermined criteria. Statistical analysis was conducted to evaluate differences in quality among the study groups. Results: The esophagus and stomach had a consistent distribution pattern of contrast medium, whereas 3 distribution patterns of contrast medium were identified in the small intestine, regardless of barium concentration. Significant differences in imaging quality were detected among the 3 groups. Conclusions and Clinical Relevance: Radiographic procedures were tolerated well by all snakes. The 35% concentration of contrast medium yielded the best imaging quality. Use of contrast medium for evaluation of the cranial portion of the gastrointestinal tract could be a reliable technique for the diagnosis of gastrointestinal diseases in ball pythons. However, results of this study may not translate to other snake species because of variables identified in this group of snakes.
Afficher plus [+] Moins [-]Micro-computed tomography of the head and dentition in cadavers of clinically normal rabbits
2012
Objective: To describe the anatomic features of dentition and surrounding structures of the head in rabbits assessed by use of a newly developed micro-computed tomography (CT) device. Sample: Cadavers of 7 clinically normal adult Dendermonde White domestic rabbits raised for human consumption. Procedures: The rabbits were slaughtered in a slaughterhouse, flayed, and decapitated; the rabbit heads were frozen for micro-CT examination. Transverse images were obtained from the nares to the occipital condyles with a custom-designed micro-CT scanner built at the Ghent University Centre for X-ray Tomography. Scan settings were chosen to highlight bony structures on the basis of the designers' experience. The micro-CT images were reviewed, and all recognizable anatomic features were labeled. Afterward, micro-CT images were used to create 3-D reconstructions by use of a custom-developed reconstruction package and 3-D rendering with dedicated software. Results: Microstructures of the bones and teeth were clearly visible on micro-CT images. Conversely, soft tissue contrast was relatively poor on these images. Conclusions and Clinical Relevance: Micro-CT appeared to be a promising technique for appropriate diagnosis of dental disease in rabbits. Further research is needed to determine the clinical applications of micro-CT imaging.
Afficher plus [+] Moins [-]Evaluation of the biliary and brain distribution of technetium Tc 99m sestamibi in healthy dogs with the ABCB1 wildtype genotype before and after treatment with spinosad
2012
MacKay, Christopher S. | Mattoon, John S. | Roberts, Gregory D. | Tucker, Russell L. | Morimoto, Trevor R. | Mealey, Katrina L.
Objective: To determine whether the reported drug-drug interaction between the flea medication spinosad and ivermectin is attributable to inhibition of P-glycoprotein by spinosad. Animals: 6 healthy adult dogs with the ABCB1 wildtype genotype. Procedures: The study was conducted as a prospective, masked, randomized crossover design. Six dogs were allocated to 2 groups; each dog served as its own control animal. Dogs in one of the groups received spinosad at the manufacturer's recommended dose; the other group received no treatment. Forty-eight hours later, scintigraphic imaging of the head and abdomen were performed with the radiolabeled P-glycoprotein substrate methoxy-isobutyl-isonitrile (sestamibi) in both groups of dogs. After a washout period of 60 days, the dogs in each group received the alternate treatment, and scintigraphic imaging again was performed 48 hours later. Gallbladder-to-liver and brain-to-neck musculature ratios of technetium Tc 99m sestamibi were calculated for each dog and compared between treatments. Results: No significant differences in gallbladder-to-liver or brain-to-neck musculature ratios were found between treatments. Conclusions and Clinical Relevance: Results provided evidence that spinosad did not inhibit P-glycoprotein function 48 hours after spinosad was administered at the manufacturer's recommended dose. Further investigations will be necessary to elucidate the mechanism of the reported toxic interaction between spinosad and ivermectin.
Afficher plus [+] Moins [-]Biomechanical and computational evaluation of two loading transfer concepts for pancarpal arthrodesis in dogs
2012
Rothstock, Stephan | Kowaleski, Michael P. | Boudrieau, Randy J. | Beale, Brian | Piras, Alessandro | Ryan, Mark | Boure, Ludovic | Brianza, Stefano
Objective: To evaluate 2 plate designs for pancarpal arthrodesis and their effects on load transfer to the respective bones as well as to develop a computational model with directed input from the biomechanical testing of the 2 constructs. Sample: Both forelimbs from the cadaver of an adult castrated male Golden Retriever. Procedures: CT imaging was performed on the forelimb pair. Each forelimb was subsequently instrumented with a hybrid dynamic compression plate or a castless pancarpal arthrodesis plate. Biomechanical testing was performed. The forelimbs were statically loaded in the elastic range and then cyclically loaded to failure. Finite element (FE) modeling was used to compare the 2 plate designs with respect to bone and implant stress distribution and magnitude when loaded. Results: Cyclic loading to failure elicited failure patterns similar to those observed clinically. The mean ± SD error between computational and experimental strain was < 15% ± 13% at the maximum loads applied during static elastic loading. The highest bone stresses were at the distal extent of the metacarpal bones at the level of the screw holes with both plates; however, the compression plate resulted in slightly greater stresses than did the arthrodesis plate. Both models also revealed an increase in bone stress at the proximal screw position in the radius. The highest plate stress was identified at the level of the radiocarpal bone, and an increased screw stress (junction of screw head with shaft) was identified at both the most proximal and distal ends of the plates. Conclusions and Clinical Relevance: The FE model successfully approximated the biomechanical characteristics of an ex vivo pancarpal plate construct for comparison of the effects of application of different plate designs.
Afficher plus [+] Moins [-]Evaluation of a B-cell leukemia-lymphoma 2-specific radiolabeled peptide nucleic acid–peptide conjugate for scintigraphic detection of neoplastic lymphocytes in dogs with B-cell lymphoma
2012
Statham-Ringen, Kimberly A. | Selting, Kimberly A. | Lattimer, Jimmy C. | Henry, Carolyn J. | Green, Jonathan A. | Bryan, Jeffrey N. | Jia, Fang | Lewis, Michael R.
Objective: To evaluate use of a radiolabeled peptide nucleic acid–peptide conjugate (RaPP) targeting B-cell leukemia-lymphoma 2 (BCL2) mRNA for scintigraphic detection of neoplastic lymphocytes in dogs with B-cell lymphoma and to assess associations among RaPP uptake, time to tumor progression (TTP), and BCL2 mRNA expression. Animals: 11 dogs with B-cell lymphoma and 1 clinically normal dog. Procedures: Scintigraphic images were acquired 1 hour after IV injection of the RaPP. Regions of interest (ROIs) were drawn around lymph nodes, liver, and spleen; ROI intensity (relative to that of an equally sized region of muscle in the same image) was measured. Each ROI was also subjectively categorized as positive or negative for increased RaPP uptake. Expression of BCL2 mRNA was determined via quantitative reverse transcriptase PCR assay of a lymph node sample from dogs with lymphoma. Associations among imaging results, TTP, and BCL2 mRNA expression were evaluated. Results: Increased RaPP uptake was detected in affected tissues of dogs with lymphoma. Dogs with superficial cervical lymph node ROIs categorized as negative (n = 8) for increased RaPP uptake had a significantly longer TTP than did dogs for which this ROI was considered positive (2). Measured intensity of mandibular and superficial cervical lymph node ROIs was negatively associated with TTP. Associations among BCL2 mRNA and ROI intensity or TTP were not significant. Conclusions and Clinical Relevance: Increased RaPP uptake at mandibular or superficial cervical lymph node ROIs may be a negative prognostic indicator in dogs with lymphoma. A larger investigation is needed to determine clinical value of the RaPP for disease detection and prognostication.
Afficher plus [+] Moins [-]