Affiner votre recherche
Résultats 1-10 de 25
Association of oxidative stress biomarkers and clinical mastitis incidence in dairy cows during the periparturient period Texte intégral
2020
Laliotis, George P. | Koutsouli, Panagiota | Sotirakoglou, Kyriaki | Savoini, Giovanni | Politis, Ioannis
Association of oxidative stress biomarkers and clinical mastitis incidence in dairy cows during the periparturient period Texte intégral
2020
Laliotis, George P. | Koutsouli, Panagiota | Sotirakoglou, Kyriaki | Savoini, Giovanni | Politis, Ioannis
The aim of this study was to determine changes of reactive oxygen species (ROS), serum antioxidant capacity (SAC), oxidative stress index (OSi), and α-tocopherol (α-T) during the periparturient period in healthy and mastitic cows and to further investigate whether these parameters can be used as a tool for identifying cows at higher risk of developing mastitis. Blood samples from 110 dairy cows from two commercial farms were obtained at dry-off, calving, and 30 days post-partum. Healthy cows formed group A (n = 90) and mastitic cows B (n = 20). Blood serum was obtained by centrifugation, and the aforementioned parameters were determined. A general linear model was used for analysing the associations among the determined blood parameters, the health of the animals’ udder, and the sampling time. ROS and OSi values were higher (P < 0.001) by a respective 14% and 26%, and SAC values lower (P < 0.001) by 10% in group B than in group A at calving. ROC curve analysis revealed that all determined parameters at calving and α-T at dry-off and 30 days post-partum had excellent or acceptable predicting ability for mastitis incidence. This information provides a tool for early identification of cows at high risk of developing mastitis, allowing the implementation of intervention strategies.
Afficher plus [+] Moins [-]Association of oxidative stress biomarkers and clinical mastitis incidence in dairy cows during the periparturient period Texte intégral
2020
Laliotis George P. | Koutsouli Panagiota | Sotirakoglou Kyriaki | Savoini Giovanni | Politis Ioannis
The aim of this study was to determine changes of reactive oxygen species (ROS), serum antioxidant capacity (SAC), oxidative stress index (OSi), and α-tocopherol (α-T) during the periparturient period in healthy and mastitic cows and to further investigate whether these parameters can be used as a tool for identifying cows at higher risk of developing mastitis.
Afficher plus [+] Moins [-]Use of a 3-Telsa magnet to perform delayed gadolinium-enhanced magnetic resonance imaging of the distal interphalangeal joint of horses with and without naturally occurring osteoarthritis Texte intégral
2018
Bishofberger, Andrea S. | Furst, Anton E. | Torgerson, Paul R. | Carstens, Ann | Hilbe, Monika | Kircher, Patrick
OBJECTIVE To characterize delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) features of healthy hyaline cartilage of the distal interphalangeal joint (DIPJ) of horses, to determine whether dGEMRIC can be used to differentiate various stages of naturally occurring osteoarthritis of the DIPJ, and to correlate relaxation times determined by dGEMRIC with the glycosaminoglycan concentration, water content, and macroscopic and histologic findings of hyaline cartilage of DIPJs with and without osteoarthritis. SAMPLE 1 cadaveric forelimb DIPJ from each of 12 adult warmblood horses. PROCEDURES T1-weighted cartilage relaxation times were obtained for predetermined sites of the DIPJ before (T1preGd) and after (T1postGd) intra-articular gadolinium administration. Corresponding cartilage sites underwent macroscopic, histologic, and immunohistochemical evaluation, and cartilage glycosaminoglycan concentration and water content were determined. Median T1preGd and T1postGd were correlated with macroscopic, histologic, and biochemical data. Mixed generalized linear models were created to evaluate the effects of cartilage site, articular surface, and macroscopic and histologic scores on relaxation times. RESULTS 122 cartilage specimens were analyzed. Median T1postGd was lower than the median T1preGd for normal and diseased cartilage. Both T1preGd and T1postGd were correlated with macroscopic and histologic scores, whereby T1preGd increased and T1postGd decreased as osteoarthritis progressed. There was topographic variation of T1preGd and T1postGd within the DIPJ. Cartilage glycosaminoglycan concentration and water content were significantly correlated with T1preGd and macroscopic and histologic scores but were not correlated with T1postGd. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that dGEMRIC relaxation times varied for DIPJs with various degrees of osteoarthritis. These findings may help facilitate early detection of osteoarthritis.
Afficher plus [+] Moins [-]Effect of various testing conditions on results for a handheld reference point indentation instrument in horses Texte intégral
2016
Lescun, Timothy B. | Hoffseth, Kevin | Yang, Henry T. | Hansma, Paul K. | Kopeikin, Hal S. | Chandrasekar, Srinivasan
OBJECTIVE To compare results obtained with a handheld reference point indentation instrument for bone material strength index (BMSi) measurements in the equine third metacarpal bone for various testing conditions. SAMPLE 24 third metacarpal bones. PROCEDURES Third metacarpal bones from both forelimbs of 12 horses were obtained. The dorsal surface of each bone was divided into 6 testing regions. In vivo and ex vivo measurements of BMSi were obtained through the skin and on exposed bone, respectively, to determine effects of each testing condition. Difference plots were used to assess agreement between BMSi obtained for various conditions. Linear regression analysis was used to assess effects of age, sex, and body weight on BMSi. A mixed-model ANOVA was used to assess effects of age, sex, limb, bone region, and testing condition on BMSi values. RESULTS Indentation measurements were performed on standing sedated and recumbent anesthetized horses and on cadaveric bone. Regional differences in BMSi values were detected in adult horses. A significant linear relationship (r2 = 0.71) was found between body weight and BMSi values. There was no difference between in vivo and ex vivo BMSi values. A small constant bias was detected between BMSi obtained through the skin, compared with values obtained directly on bone. CONCLUSIONS AND CLINICAL RELEVANCE Reference point indentation can be used for in vivo assessment of the resistance of bone tissue to microfracture in horses. Testing through the skin should account for a small constant bias, compared with results for testing directly on exposed bone.
Afficher plus [+] Moins [-]Effect of laser treatment on first-intention incisional wound healing in ball pythons (Python regius) Texte intégral
2015
Cole, Grayson L. | Lux, Cassie N. | Schumacher, Juergen P. | Seibert, Rachel L. | Sadler, Ryan A. | Henderson, Andrea L. | Odoi, Agricola | Newkirk, Kim M.
OBJECTIVE To evaluate effects of laser treatment on incisional wound healing in ball pythons (Python regius). ANIMALS 6 healthy adult ball pythons. PROCEDURES Snakes were sedated, a skin biopsy specimen was collected for histologic examination, and eight 2-cm skin incisions were made in each snake; each incision was closed with staples (day 0). Gross evaluation of all incision sites was performed daily for 30 days, and a wound score was assigned. Four incisions of each snake were treated (5 J/cm2 and a wavelength of 980 nm on a continuous wave sequence) by use of a class 4 laser once daily for 7 consecutive days; the other 4 incisions were not treated. Two excisional skin biopsy specimens (1 control and 1 treatment) were collected from each snake on days 2, 7, 14, and 30 and evaluated microscopically. Scores were assigned for total inflammation, degree of fibrosis, and collagen maturity. Generalized linear models were used to investigate the effect of treatment on each variable. RESULTS Wound scores for laser-treated incisions were significantly better than scores for control incisions on day 2 but not at other time points. There were no significant differences in necrosis, fibroplasia, inflammation, granuloma formation, or bacterial contamination between control and treatment groups. Collagen maturity was significantly better for the laser-treated incisions on day 14. CONCLUSIONS AND CLINICAL RELEVANCE Laser treatment resulted in a significant increase in collagen maturity at day 14 but did not otherwise significantly improve healing of skin incisions.
Afficher plus [+] Moins [-]Temporospatial and kinetic gait variables of Doberman Pinschers with and without cervical spondylomyelopathy Texte intégral
2015
Lima, Carolina G. D. | Da Costa, Ronaldo C. | Foss, Kari D. | Allen, Matthew J.
OBJECTIVE To characterize and compare gait variables in Doberman Pinschers with and without cervical spondylomyelopathy (CSM). ANIMALS 18 Doberman Pinschers (9 clinically normal dogs and 9 CSM-affected dogs). PROCEDURES A neurologic examination was performed on all dogs. The diagnosis of CSM was confirmed with MRI. Temporospatial and kinetic gait variables were measured by use of a pressure-sensitive walkway. Temporospatial variables evaluated included stance phase duration, swing phase duration, gait cycle duration, stride length, and gait velocity. Kinetic variables evaluated included peak vertical force and vertical impulse. Random-effects linear regression was used to determine the difference between CSM-affected and clinically normal dogs for each of the 7 variables. RESULTS Values for temporospatial variables were significantly smaller in the thoracic limbs of CSM-affected dogs, compared with values for the thoracic limbs of clinically normal dogs. For the kinetic variables, peak vertical force was significantly higher in the thoracic limbs than the pelvic limbs for all dogs. Vertical impulse values were higher in the thoracic limbs than the pelvic limbs. There were significant differences in mean vertical impulse between the thoracic and pelvic limbs for both groups. CONCLUSIONS AND CLINICAL RELEVANCE In this study, significant differences in temporospatial variables were identified between the thoracic limbs of clinically normal and CSM-affected dogs, with the values being smaller for the CSM-affected dogs than for the clinically normal dogs. A pressure-sensitive walkway may provide a valid, practical option for rapid, objective assessment of gait and response to treatment in dogs with CSM.
Afficher plus [+] Moins [-]Effect of trotting speed and circle radius on movement symmetry in horses during lunging on a soft surface Texte intégral
2012
Pfau, Thilo | Stubbs, Narelle C. | Kaiser, LeeAnn J. | Brown, Lucy E.A. | Clayton, Hilary M.
Objective: To determine whether body lean angle could be predicted from circle radius and speed in horses during lunging and whether an increase in that angle would decrease the degree of movement symmetry (MS). Animals: 11 medium- to high-level dressage horses in competition training. Procedures: Body lean angle, head MS, and trunk MS were quantified during trotting while horses were instrumented with a 5-sensor global positioning system–enhanced inertial sensor system and lunged on a soft surface. Speed and circle radius were varied and used to calculate predicted body lean angle. Agreement between observed and predicted values was assessed, and the association between lean angle and MS was determined via least squares linear regression. Results: 162 trials totaling 3,368 strides (mean, 21 strides/trial) representing trotting speeds of 1.5 to 4.7 m/s and circle radii of 1.8 to 11.2 m were conducted in both lunging directions. Differences between observed and predicted lean angles were small (mean ± SD difference, −1.2 ± 2.4°) but significantly greater for circling to the right versus left. Movement symmetry values had a larger spread for the head than for the pelvis, and values of all but 1 MS variable changed with body lean angle. Conclusions and Clinical Relevance: Body lean angle agreed well with predictions from gravitational and centripetal forces, but differences observed between lunging directions emphasize the need to investigate other factors that might influence this variable. For a fair comparison of MS between directions, body lean angle needs to be controlled for or corrected with the regression equations. Whether the regression equations need to be adapted for lame horses requires additional investigation.
Afficher plus [+] Moins [-]Influence of exercise on the distribution of technetium Tc 99m medronate following intra-articular injection in horses Texte intégral
2012
Dulin, Jennifer A. | Drost, W Tod | Phelps, Mitch A. | Santschi, Elizabeth M. | Menendez, Maria I. | Bertone, Alicia L.
Objective: To determine the effects of exercise on the distribution and pharmacokinetics of technetium Tc 99m medronate (99mTc-MDP) following intra-articular (IA) injection in horses. Animals: 5 horses. Procedures: 1 antebrachiocarpal joint (ACJ)/horse was assigned to the exercised group (n = 5), and the contralateral ACJ was evaluated in the nonexercised group (5) after a minimum washout period of 7 days. Following IA injection of 99mTc-MDP (148 MBq), blood and scintigraphic images of the carpus were obtained at 5, 10, 15, 20, 25, 30, 45, 60, 90, 120, 240, 360, 480, 600, 720, and 1,440 minutes. Plasma and scintigraphic radioactivity were determined over time, and pharmacokinetic parameters were generated via noncompartmental and compartmental analyses. Each horse was monitored via physical and lameness examination and ACJ synovial fluid analysis before injection and at days 1, 2, 3, and 7. Results: Lameness was not observed. Mean ± SD synovial fluid WBC count increased at day 1 (exercised, 721 ± 234 cells/μL; nonexercised, 948 ± 223 cells/μL), but returned to baseline at days 3 and 7 Mean time to maximum plasma radioactivity was earlier in the exercised group (16.00 ± 2.35 minutes) than the nonexercised group (43.75 ± 3.64 minutes). Linear regression of the scintigraphic radioactivity-time curves revealed a greater negative slope in the exercised group within the first 25 minutes. There was no difference in absorption or elimination rate constants in a 2-compartment model. Conclusions and Clinical Relevance: IA injection of 99mTc-MDP was safe and effective for evaluating synovial solute distribution. Exercise significantly increased early transfer of 99mTc-MDP from the ACJ into plasma, although absorption and elimination rate constants were not affected. Exercise may affect synovial clearance and withdrawal times of medications administered IA.
Afficher plus [+] Moins [-]Accuracy of the use of triaxial accelerometry for measuring daily activity as a predictor of daily maintenance energy requirement in healthy adult Labrador Retrievers Texte intégral
2011
Wrigglesworth, David J. | Mort, Emily S. | Upton, Sarah L. | Miller, Andrew T.
Objective: To determine accuracy of the use of triaxial accelerometry for measuring daily activity as a predictor of maintenance energy requirement (MER) in healthy adult Labrador Retrievers. Animals—10 healthy adult Labrador Retrievers. Procedures: Dogs wore an accelerometer for two 2-week periods, with data on daily activity successfully collected for 24 to 26 days. These data, along with body weight, were used as independent variables in a multiple linear regression model to predict the dependent variable of daily MER. The predictive accuracy of the model was compared with that of a model that excluded activity. Dietary energy intake at a stated amount of body weight stability was used as an equivalent measure of MER in these analyses. Results: The multiple linear regression model that included body weight and daily activity as independent variables could be used to predict observed MER with a mean absolute error of 63.5 kcal and an SE of estimation of 94.3 kcal. Removing activity from the model reduced the predictive accuracy to a mean absolute error of 129.8 kcal and an SE of estimation of 165.4 kcal. Conclusions and Clinical Relevance: Use of triaxial accelerometers to provide an independent variable of daily activity yielded a marked improvement in predictive accuracy of the regression model, compared with that for a model that used only body weight. Improved accuracy in estimations of MER could be made for each dog if an accelerometer was used to record its daily activity.
Afficher plus [+] Moins [-]A transducer for measuring force on surgical sutures Texte intégral
2010
The objective of this study was to validate, both in vitro and in an ex vivo model, a technique for the measurement of forces exerted on surgical sutures. For this purpose, a stainless steel E-type buckle force transducer was designed and constructed. A strain gauge was mounted on the central beam of the transducer to measure transducer deformation. The transducer was tested and calibrated on a single strand of surgical suture during cyclic loading. Further validation was performed using a previously published cadaveric model of laryngoplasty in the horse. Linear regression of transducer output with actual force during calibration tests resulted in mean R2 values of 1.00, 0.99, and 0.99 for rising slope, falling slope, and overall slope, respectively. The R2 was not less than 0.96 across an average of 75 cycles per test. The difference between rising slope and falling slope was 4%. Over 45 846 samples, the predicted force from transducer output showed a mean error of 4%. In vitro validation produced an adjusted R2 of 0.99 when the force on the suture was regressed against translaryngeal pressure in a mixed-effects model. E-type buckle force transducers showed a highly linear output over a physiological force range when applied to surgical suture in vitro and in an ex vivo model of laryngoplasty. With appropriate calibration and short-term in vivo implantation, these transducers may advance our knowledge of the mechanisms of success and failure of techniques, such as laryngoplasty, that use structural suture implants.
Afficher plus [+] Moins [-]Two-dimensional left atrium–to–aorta ratios and left ventricular M-mode transthoracic echocardiographic measurements in clinically normal adult Dachshunds Texte intégral
2016
Lim, Chee Kin | Fosgate, Geoffrey T. | Green, Henry W III | Kirberger, Robert M.
OBJECTIVE To estimate the left atrium–to–aorta ratio (LA:Ao) and establish 95% prediction intervals for left ventricular M-mode transthoracic echocardiographic measurements in clinically normal adult Dachshunds. ANIMALS 40 healthy Dachshunds. PROCEDURES For each dog, 3 standard 2-D echocardiographic methods (diameter, circumference, and cross-sectional area) were used to measure the left atrium and aorta and calculate the LA:Ao from right parasternal short axis (RPSA) images obtained at the level of the aortic valve cusps. Left ventricular M-mode measurements were acquired from RPSA images obtained at the chordal level immediately below the mitral valve. Descriptive data were generated, and the 95% prediction intervals were calculated by use of an allometric scaling equation and linear regression and compared with those calculated on the basis of data obtained from dogs of multiple breeds in a previous study.RESULTS The mean (SD) LA:Ao was 1.40 (0.13), 2.09 (0.17), and 2.85 (0.48) for the diameter, circumference, and cross-sectional area methods, respectively. The 95% prediction intervals for the left ventricular M-mode measurements determined by an allometric scaling equation on the basis of Dachshund-specific data were narrower than those determined on the basis of data obtained from dogs of multiple breeds. For that allometric equation, scaling exponents on the basis of Dachshund-specific data ranged from 0.129 to 0.397 and did not absolutely conform to the presumed index for linear measurements (ie, body weight0.333). CONCLUSIONS AND CLINICAL RELEVANCE The LA:Aos and 95% prediction intervals calculated in this study can be used as preliminary guidelines for echocardiographic measurements of clinically normal Dachshunds.
Afficher plus [+] Moins [-]