Affiner votre recherche
Résultats 1-2 de 2
Discrimination of healthy versus sick steers by means of continuous remote monitoring of animal activity
2015
Smith, Jacqueline L. | Vanzant, Eric S. | Carter, Craig N. | Jackson, Carney B.
OBJECTIVE To test a unique electronic ear tag designed to collect movement data to determine whether physical activity of sick steers differed from that of healthy steers. ANIMALS 206 steers. PROCEDURES Physical activity in 2 groups of steers during November and December of 2010 (101 steers; the tag of 1 steer failed, and thus that steer was removed from the study, which resulted in data for 100 steers) and 2011 (105 steers) was monitored with an electronic ear tag device with an on-board triple-axis accelerometer. The accelerometer recorded motion in all 3 axes in the form of counts per minute. A radio-frequency transmitter on the ear tag delivered serial packets of motion data to a local server. An algorithm was developed to analyze the activity data to determine whether this technique could be used to assess health status with high accuracy. RESULTS Steers that became sick had significantly fewer activity counts (approx 25% fewer), compared with the activity counts of steers that remained healthy the entire time. CONCLUSIONS AND CLINICAL RELEVANCE In this study, automated detection of health status in growing cattle was feasible through remote monitoring of animal activity. Early identification of sick animals should lead to improved health outcomes, increased marketability, and improved animal well-being and help to minimize the use of antimicrobials that could contribute to resistant bacteria.
Afficher plus [+] Moins [-]Detection of antibodies against Corynebacterium pseudotuberculosis using surface plasmon resonance
2011
Yeoh No Na | Ngajidin Mat Siman | Sharifah Aminah Syed Mohamad | Dzaraini Kamarun | Ramlan Mohamed | Radin Siti Fadzlina Hirzin
Conventional methods of detecting Corynebacterium pseudotuberculosis, a bacterium that causes caseous lymphadenitis (CLA) in sheeps and goats focused on several serodiagnostic tests such as ELISA, Western blotting and various inhibition and precipitation techniques. This paper described a Surface Plasmon Resonance (SPR) protocol for the direct detection of polyclonal
antibodies against Corynebacterium pseudotuberculosis with immobilisation of the antigen on unmodified transducer surface. The lower limit of detection was determined to be 2 μg mL-1 of immobilised antigen (Ag). Sufficient binding interaction was monitored on unmodified transducer; and saturation of the binding interaction was observed at 80 μg mL-1 of interacted antibody.
Afficher plus [+] Moins [-]