Affiner votre recherche
Résultats 1-8 de 8
Different types of stainless steel used in equipment in meat plants do not affect the initial microbial transfer, including pathogens, from pork skin
2015
Lariviere-Gautheir, Guillaume | Quessy, Sylvain | Fournaise, Sylvain | Letellier, Ann | Fravalo, Philippe
This study describes and measures the impact of different compositions and finishes of stainless steel used in equipment in the meat industry on the transfer of natural flora and selected pathogens from artificially contaminated pork skin. It is known that the adhesion to surfaces of Listeria monocytogenes and Salmonella, 2 pathogens frequently found in contaminated pork meat, depends on the nature and roughness of the surface. Our results show no statistically significant differences in microbial transfer regardless of the types of stainless steel considered, with the highest measured transfer difference being 0.18 log colony-forming units (CFUs)/800 cm2. Moreover, no differences in total microbial community were observed after transfer on the 5 types of stainless steel using single-strand conformation polymorphism (SSCP). It was concluded that the different characteristics of the stainless steel tested did not affect the initial bacterial transfer in this study.
Afficher plus [+] Moins [-]Influence of temperature and organic load on chemical disinfection of Geobacillus steareothermophilus spores, a surrogate for Bacillus anthracis
2013
Guan, Jiewen | Chan, Maria | Brooks, Brian W. | Rohonczy, Liz
This study evaluated the influence of temperature and organic load on the effectiveness of domestic bleach (DB), Surface Decontamination Foam (SDF), and Virkon in inactivating Geobacillus stearothermophilus spores, which are a surrogate for Bacillus anthracis spores. The spores were suspended in light or heavy organic preparations and the suspension was applied to stainless steel carrier disks. The dried spore inoculum was covered with the disinfectants and the disks were then incubated at various temperatures. At −20°C, the 3 disinfectants caused less than a 2.0 log10 reduction of spores in both organic preparations during a 24-h test period. At 4°C, the DB caused a 4.4 log10 reduction of spores in light organic preparations within 2 h, which was about 3 log10 higher than what was achieved with SDF or Virkon. In heavy organic preparations, after 24 h at 4°C the SDF had reduced the spore count by 4.5 log10, which was about 2 log10 higher than for DB or Virkon. In general, the disinfectants were most effective at 23°C but a 24-h contact time was required for SDF and Virkon to reduce spore counts in both organic preparations by at least 5.5 log10. Comparable disinfecting activity with DB only occurred with the light organic load. In summary, at temperatures as low as 4°C, DB was the most effective disinfectant, inactivating spores within 2 h on surfaces with a light organic candload, whereas SDF produced the greatest reduction of spores within 24 h on surfaces with a heavy organic load.
Afficher plus [+] Moins [-]A transducer for measuring force on surgical sutures
2010
The objective of this study was to validate, both in vitro and in an ex vivo model, a technique for the measurement of forces exerted on surgical sutures. For this purpose, a stainless steel E-type buckle force transducer was designed and constructed. A strain gauge was mounted on the central beam of the transducer to measure transducer deformation. The transducer was tested and calibrated on a single strand of surgical suture during cyclic loading. Further validation was performed using a previously published cadaveric model of laryngoplasty in the horse. Linear regression of transducer output with actual force during calibration tests resulted in mean R2 values of 1.00, 0.99, and 0.99 for rising slope, falling slope, and overall slope, respectively. The R2 was not less than 0.96 across an average of 75 cycles per test. The difference between rising slope and falling slope was 4%. Over 45 846 samples, the predicted force from transducer output showed a mean error of 4%. In vitro validation produced an adjusted R2 of 0.99 when the force on the suture was regressed against translaryngeal pressure in a mixed-effects model. E-type buckle force transducers showed a highly linear output over a physiological force range when applied to surgical suture in vitro and in an ex vivo model of laryngoplasty. With appropriate calibration and short-term in vivo implantation, these transducers may advance our knowledge of the mechanisms of success and failure of techniques, such as laryngoplasty, that use structural suture implants.
Afficher plus [+] Moins [-]Retrospective analysis of corrosion and ion release from retrieved cast stainless steel tibia plateau leveling osteotomy plates in dogs with and without peri-implant osteosarcoma
2018
Sprecher, Christoph M. | Milz, S. (Stefan) | Suter, Thomas | Keating, John H. | McCarthy, Robert J. | Gueorguiev, Boyko | Boudrieau, Randy J.
OBJECTIVE To evaluate and compare surface and cross-sectional structure as well as localized electrochemical corrosion and ion release for cast stainless steel (SS) tibia plateau leveling osteotomy (TPLO) plates retrieved from dogs with and without osteosarcoma (OSA) and to compare these findings with similar variables for forged SS TPLO plates retrieved from dogs. SAMPLE 47 TPLO plates explanted from 45 client-owned dogs (22 cast plates from dogs with OSA, 22 cast plates from dogs without OSA, and 3 forged plates from dogs without OSA). PROCEDURES Histologic evaluations of tissue samples collected from implant sites at the time of plate retrieval were performed to confirm implant site tumor status of each dog. Surfaces and metallographic cross sections of retrieved plates were examined, and the microcell technique was used to obtain local electrochemical corrosion and ion release measurements. RESULTS Findings indicated that all cast SS plates demonstrated high spatial variability of their electrochemical surface properties and inhomogeneous superficial and cross-sectional composition, compared with forged plates. Greater metal ion release was observed in cast plates than in forged plates and in cast plates from dogs with OSA than in cast or forged from dogs without OSA. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that accumulation of metal ions from implants could be a trigger for neoplastic transformation in neighboring cells. Metal ion release caused by corrosion of implants that do not comply with recommended standards of the American Society for Testing and Materials International or the International Organization for Standardization could potentially place patients at increased risk of tumor development.
Afficher plus [+] Moins [-]Magnetic resonance imaging susceptibility artifacts in the cervical vertebrae and spinal cord related to monocortical screw–polymethylmethacrylate implants in canine cadavers
2017
Jones, B. G. | Fosgate, Geoffrey T. | Green, Eric M. | Habing, Amy M. | Hettlich, Bianca F.
OBJECTIVE To characterize and compare MRI susceptibility artifacts related to titanium and stainless steel monocortical screws in the cervical vertebrae and spinal cord of canine cadavers. SAMPLE 12 canine cadavers. PROCEDURES Cervical vertebrae (C4 and C5) were surgically stabilized with titanium or stainless steel monocortical screws and polymethylmethacrylate. Routine T1-weighted, T2-weighted, and short tau inversion recovery sequences were performed at 3.0 T. Magnetic susceptibility artifacts in 20 regions of interest (ROIs) across 4 contiguous vertebrae (C3 through C6) were scored by use of an established scoring system. RESULTS Artifact scores for stainless steel screws were significantly greater than scores for titanium screws at 18 of 20 ROIs. Artifact scores for titanium screws were significantly higher for spinal cord ROIs within the implanted vertebrae. Artifact scores for stainless steel screws at C3 were significantly less than at the other 3 cervical vertebrae. CONCLUSIONS AND CLINICAL RELEVANCE Evaluation of routine MRI sequences obtained at 3.0 T revealed that susceptibility artifacts related to titanium monocortical screws were considered mild and should not hinder the overall clinical assessment of the cervical vertebrae and spinal cord. However, mild focal artifacts may obscure small portions of the spinal cord or intervertebral discs immediately adjacent to titanium screws. Severe artifacts related to stainless steel screws were more likely to result in routine MRI sequences being nondiagnostic; however, artifacts may be mitigated by implant positioning.
Afficher plus [+] Moins [-]Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs
2017
Darrow, Brett G. | Biskup, Jeffrey J. | Weigel, Joseph P. | Jones, Michael P. | Xie, Xie | Liaw, P. K. (Peter K.) | Tharpe, Josh L. | Sharma, Aashish | Penumadu, Dayakar
OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.
Afficher plus [+] Moins [-]Safety and efficacy of cold atmospheric plasma for the sterilization of a Pasteurella multocida–contaminated subcutaneously implanted foreign body in rabbits
2021
Avellar, Haileigh K. | Williams, Megan R. | Brandao, Joao | Narayanan, Sai | Ramachandran, Akhilesh | Holbrook, Todd C. | Schoonover, Mike J. | Bailey, Keith L. | Payton, Mark E. | Pai, Kedar Kamlakant | Timmons, Chris T.
OBJECTIVE To determine whether a stainless steel implant sterilized with a novel cold atmospheric plasma sterilization (CAPS) device adversely affects local tissues in rabbits and whether CAPS was as effective as steam sterilization with an autoclave to inactivate Pasteurella multocida. ANIMALS 31 healthy New Zealand White rabbits. PROCEDURES Steam-autoclaved stainless steel implants inoculated with P multocida underwent a second steam autoclave sterilization (AIA) or CAPS (AICAPS). One AIA implant and 3 AICAPS implants were randomly placed subcutaneously at 4 sites in 21 rabbits (84 implants). These rabbits were monitored daily for 5 days for evidence of systemic illness and local tissue reactions at the implantation sites and then euthanized. Samples were taken from each implant site for bacterial culture and histologic examination. RESULTS Cultures of samples obtained from all sites were negative for bacterial growth. No significant difference was observed in mean skin thickness or erythema between AIA and AICAPS implant sites on any observed day. Also, individual histologic grades for the epidermis, dermis, subcutis, and muscle and total histologic grade were not significantly different between AIA and AICAPS implant sites. CONCLUSIONS AND CLINICAL RELEVANCE Cold atmospheric plasma sterilization was noninferior to steam sterilization of P multocida–contaminated stainless steel implants in the rabbits in the present study. However, studies of the efficacy of CAPS for inactivation of other important bacteria are needed.
Afficher plus [+] Moins [-]Enhanced inactivation of avian influenza virus at −20°C by disinfectants supplemented with calcium chloride or other antifreeze agents
2015
Guan, Jiewen | Chan, Maria | Brooks, Brian W. | Rohonczy, Elizabeth
Avian influenza outbreaks have occurred during winter months, and effective disinfection of poultry premises at freezing temperatures is needed. The commercial disinfectants Virkon and Accel, supplemented with an antifreeze agent [propylene glycol (PG), methanol (MeOH), or calcium chloride (CaCl2)], were evaluated for their effectiveness in killing avian influenza virus (AIV) at −20°C or 21°C. An AIV suspension was applied to stainless steel disks, air-dried, and covered with a disinfectant or antifreeze agent for 5 to 30 min. Virkon (2%) and Accel (6.25%) with 30% PG, 20% MeOH, or 20% CaCl2 inactivated 6 log10 AIV within 5 min at −20°C and 21°C. At these temperatures PG and MeOH alone did not kill AIV, but the 20% CaCl2 solution alone inactivated 5 log10 AIV within 10 min. The results suggested that CaCl2 is potentially useful to enhance the effectiveness of disinfection of poultry facilities after outbreaks of AIV infection in warm and cold seasons.
Afficher plus [+] Moins [-]