Affiner votre recherche
Résultats 1-10 de 77
Sandwich enzyme-linked immunosorbent assay for quantitative measurement of serum amyloid A protein in horses.
1995
Satoh M. | Fujinaga T. | Okumura M. | Hagio M.
To measure the concentration of serum amyloid A (SAA) protein in horses a sensitive and highly reproducible sandwich (ELISA) was established, using affinity purified SAA antibody. Results of the ELISA were found to have a high correlation (r = 0.95) with those of the single radial immunodiffusion test. Equine SAA concentration was measured by use of this ELISA. In clinically normal horses, the concentration of SAA was high immediately after birth to 2 weeks of age. After that, SAA concentration had periodic fluctuations in the range of approximately 10 to 30 microgram/ml. Mean (+/- SD) concentrations of SAA in foals (less than or equal to 12 months old) and adult horses (greater than or equal to 18 months old) were 21.23 +/- 12.20 and 14.93 +/- 9.07 microgram/ml, respectively. In mares during the perinatal period, SAA concentration remained stable within the reference range before parturition. It increased quickly after delivery, and reached a peak value of 101.29 +/- 98.82 microgram/ml on postpartum day 3, then began to decrease, at postpartum week 2, to the reference range by the end of postpartum month 1. In horses with experimentally induced inflammation, SAA concentration increased quickly and reached approximately four- to 40-fold increase over the pretreatment value on day 1 and remained high on days 2 to h after treatment. It then returned to the baseline value by 2 to 4 weeks in association with disappearance of local signs of inflammation. The SAA concentration was high in most horses with clinical signs of inflammation. It was concluded from these data that this ELISA is sensitive and reliable for measuring SAA in horses.
Afficher plus [+] Moins [-]Enzyme-linked immunosorbent assay for screening of milk samples for Salmonella typhimurium in dairy herds.
1995
Hoorfar J. | Wedderkopp A.
We investigated the ability of an antibody-specific, O antigen-based ELISA to document Salmonella typhimurium herd infections by screening of milk samples. Three cattle populations, 20 herds with no history of salmonellosis, 8 herds with history of S. typhimurium episodes within the previous 7 months, and 220 herds of unknown disease status, were tested. A herd was considered ELISA positive if at least 5% of the cows had OD values > 0.3. Among the 20 herds without history of salmonellosis, only 2 herds were ELISA positive, whereas all 8 herds with a known history of salmonellosis were ELISA positive (herd specificity, 0.9 and herd sensitivity, 1.0). A significant correlation (P < 0.001) was found between the OD values of serum and milk samples from cows in the herds with a history of salmonellosis. It was concluded that ELISA testing of individual milk samples can be used for surveillance of herds for S. typhimurium infections, but further modifications are needed to test bulk tank milk samples.
Afficher plus [+] Moins [-]Evaluation of an enzyme-linked immunosorbent assay for diagnosis of paratuberculosis in goats.
1994
Burnside D.M. | Rowley B.O.
A commercial rapid-absorbed ELISA developed to detect antibodies to Mycobacterium paratuberculosis in bovine serum was modified for use with goat serum. Diagnostic sensitivity was evaluated, using a group of 163 goats from a herd with endemic paratuberculosis. Blood and fecal samples were obtained simultaneously, and prevalence of shedding of M paratuberculosis in the feces was estimated by detection of DNA of the mycobacterial insertion sequence, IS900, using a commercial test kit. Diagnostic specificity was evaluated, using blood samples from a total of 123 goats in 10 herds that were considered clinically free of paratuberculosis. The IS900 DNA was detected in 35 of the 163 goats (21%) from the infected herd. Serum antibody to M paratuberculosis was detected in 19 of the 35 IS900 DNA-positive goats, for apparent sensitivity of 54%. Serum antibody was detected in 18 of the 128 IS900 DNA-negative goats from the infected herd. Negative results for serum antibody to M paratuberculosis were obtained for all 123 goats from the herds that were considered clinically free of paratuberculosis.
Afficher plus [+] Moins [-]Evaluation of an enzyme-linked immunosorbent assay for detection of Eperythrozoon suis antibodies in swine.
1992
Hsu F.S. | Liu M.C. | Chou S.M. | Zachary J.F. | Smith A.R.
An ELISA was developed and tested to detect antibodies to Eperythrozoon suis in swine. Results were compare with those of the indirect hemagglutination (IHA) test. Antigen isolated from swine heavily infected with E suis was used for both tests. Comparison of the ELISA with the IHA test revealed a significant (P < 0.001) correlation between results. Of 114 samples obtained from 9 swine infected with E suis, 8 7.7% were seropositive (titer greater than or equal to 200) via the ELISA, and 80.7% were seropositive (titer greater than or equal to 20) via the IHA test. The sensitivity of the ELISA was greater than that of the IHA test. All blood samples obtained from specific-pathogen-free swine tested negative for E suis antibody. Cross-reactions were not observed between E suis antigen and antisera against various swine and cattle disease agents using ELISA. We concluded that the ELISA may be used for rapid and effective diagnosis of infection with E suis in swine.
Afficher plus [+] Moins [-]Survey of trichinosis in breeding and cull swine, using an enzyme-linked immunosorbent assay.
1990
Cowen P. | Li S. | McGinn T. III
Serum samples obtained from 40,927 swine at various locations in North Carolina between Aug 1, 1987 and July 31, 1988, were tested for antibodies to Trichinella spiralis, using an ELISA based on a larval T spiralis excretory-secretory antigen. In the ELISA, samples were considered to have positive results if the optical density (OD) reading was equal to or 5 times greater than the mean OD value of 4 negative-control sera from trichina-free swine. Of the 40,927 serum samples tested, 154 (0.38%) were positive by ELISA; the rate for breeding swine was 0.35% (105/30,162), and the rate for cull swine was 0.45% (49/10,765). Of the 49 seropositive samples from cull swine, 11 were from out of the state, 22 had no identification, and 16 were known to originate from North Carolina. Seropositivity had a bimodally seasonal distribution, with peaks in March and September. There was no difference between the mean age of seropositive and seronegative swine, but males were at greater risk for seropositivity than were females. Pigs from lots with < 100 sera tested were at increased risk for seropositivity, as were pigs from the central coastal region of North Carolina.
Afficher plus [+] Moins [-]Development of an enzyme-linked immunosorbent assay to detect IgG, IgM, and complement (C3) on canine erythrocytes.
1989
Porter R.E. Jr. | Weiser M.G. | Callahan G.N.
An ELISA was used to detect IgG, IgM, and complement (C3) on the surface of canine erythrocytes. Erythrocytes were placed in wells of a microtitration plate and incubated with affinity purified, alkaline phosphatase-conjugated anti-canine IgG, IgM, or C3. Results of the ELISA were compared with the direct antiglobulin test (DAT) by preparing standard reference curves from canine blood type A erythrocytes that had been incubated with serial dilutions (1:2 to 1:8,192) of canine anti-A serum. The ELISA detected increased erythrocyte-bound immunoglobulin and complement at two- to fourfold dilutions greater than thoe required for positive results with the DAT. The ELISA required small sample and reagent volumes and detected lower concentrations of immune components than did the DAT.
Afficher plus [+] Moins [-]Use of viable-cell ELISA for detection of monoclonal antibodies recognizing tumor-associated antigens on bovine lymphosarcoma cells.
1987
Aida Y. | Onuma M. | Kasai N. | Izawa H.
Herd evaluation of Fasciola hepatica infection levels in Louisiana cattle by an enzyme-linked immunosorbent assay.
1987
Welch R.D. | Smith P.H. | Malone J.B. | Holmes R.A. | Geaghan J.P.
Use of ELISA for detection of immunoglobulins G and M that recognize Salmonella dublin lipopolysaccharide for prediction of carrier status in cattle.
1990
Spier S.J. | Smith B.P. | Tyler J.W. | Cullor J.S. | Dilling G.W. | Pfaff L.D.
Immunoglobulin reactions to Salmonella dublin in serum and milk from 4 groups of lactating cows were measured by an indirect ELISA. The groups consisted of (1) cows that were natural carriers of S dublin in the mammary gland, (2) experimentally infected cows that did not become carriers, (3) cows inoculated with a commercial S dublin bacterin, and (4) cows used as S dublin-negative controls. Milk and serum samples were obtained at monthly intervals. Models for predicting carrier status were developed by use of stepwise logistic regression. Independent variables consisted of serum and milk IgG and IgM titers to S dublin lipopolysaccharide and a ratio of IgG to IgM. The utility of a single sample vs multiple samples obtained at 1-month or 2-month intervals was tested by comparison of goodness-of-fit X2 P values for 8 models predicting carrier status. Immunoglobulin reactions specific to S dublin were a significant predictor of carrier status (P < 0.001). Serum IgG titers specific for S dublin were the most important variable for predicting carrier status. Two serum IgG titers to S dublin obtained 2 months apart was a better predictor of carrier status than measurement of the IgG:IgM ratio from a single serum sample. Immunoglobulin recognizing S dublin epitopes also were detected in milk samples. In milk, performing 2 ELISA 60 days apart to determine IgG and IgM reactions to S dublin appeared to be useful for the prediction of carrier status, but was not as accurate as models for serum immunoglobulin reactions.
Afficher plus [+] Moins [-]Development and evaluation of an enzyme-linked immunosorbent assay for bovine antibody (IgG) to Pasteurella haemolytica.
1989
Gillette K.G. | Frank G.H. | Sacks J.M.
The sensitivity of an indirect enzyme-linked immunosorbent assay (ELISA) for bovine IgG serum antibody to Pasteurella haemolytica was compared with that of an indirect hemagglutination (IHA) test. Pasteurella haemolytica serotypes were grown in a chemically defined cell culture medium, and soluble antigens released into the growth medium were used in the ELISA and IHA test. An ELISA with serotype-1 antigen consistently detected antibody in sera that were positive by IHA test (correlation, 99%). Sera reacting with serotype-1 ELISA antigens also reacted with ELISA antigens prepared from other serotypes. Although ELISA titers determined by the 2 methods were approximately linear. Titer increases detected in paired serum samples by either test were similar. The ELISA was more sensitive than was the IHA in detecting colostral IgG antibody in serum of newborn calves. The ELISA uses a simple, stable antigen preparation and detects antibody to P haemolytica serotypes that commonly infect cattle.
Afficher plus [+] Moins [-]