Affiner votre recherche
Résultats 1-2 de 2
Changes in synovial fluid biomarker concentrations following arthroscopic surgery in horses with osteochondritis dissecans of the distal intermediate ridge of the tibia
2015
Brink, Palle | Smith, Roger K. W. | Tverdal, Aage | Dolvik, Nils I.
OBJECTIVE To quantify concentrations of cartilage oligomeric matrix protein (COMP) and fibromodulin in synovial fluid from the tarsocrural joints (TCJs) of horses with osteochondritis dissecans (OCD) of the distal intermediate ridge of the tibia and determine whether concentrations would change following arthroscopic removal of osteochondral fragments. ANIMALS 115 client-owned horses with OCD of the TCJ and 29 control horses euthanized for unrelated reasons. PROCEDURES COMP and fibromodulin concentrations were measured in synovial fluid from the TCJs of the affected horses before and after osteochondral fragments were removed arthroscopically and in synovial fluid from the TCJs of the control horses after euthanasia. Synovial biopsy specimens from the TCJs of affected and control horses were examined histologically for evidence of inflammation. RESULTS Synovial fluid COMP and fibromodulin concentrations prior to surgery in horses with OCD were not significantly different from concentrations in control horses. Fibromodulin, but not COMP, concentration in horses with OCD was significantly decreased after surgery, compared with the concentration before surgery. Fibromodulin concentration was significantly correlated with joint effusion score but not with lameness score or results of a flexion test and was correlated with histologic score for number of synoviocytes on the surface of the synovium but not with score for degree of infiltration of inflammatory cells in the synovium. Synovial fluid COMP concentration was not significantly correlated with clinical or histologic findings. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that fibromodulin, but not COMP, could potentially be a biomarker of joint inflammation in horses with OCD of the TCJ.
Afficher plus [+] Moins [-]Effect of histologic processing on dimensions of skin samples obtained from cat cadavers
2015
Jeyakumar, Sakthila | Smith, Annette N. | Schleis, Stephanie E. | Cattley, Russell C. | Tillson, Michael | Henderson, Ralph A.
OBJECTIVE To determine changes in dimensions of feline skin samples as a result of histologic processing and to identify factors that contributed to changes in dimensions of skin samples after sample collection. SAMPLE Cadavers of 12 clinically normal cats. PROCEDURES Skin samples were obtained bilaterally from 3 locations (neck, thorax, and tibia) of each cadaver; half of the thoracic samples included underlying muscle. Length, width, and depth were measured at 5 time points (before excision, after excision, after application of ink to mark tissue margins, after fixation in neutral-buffered 10% formalin for 36 hours, and after completion of histologic processing and staining with H&E stain). Measurements obtained after sample collection were compared with measurements obtained before excision. RESULTS At the final time point, tissue samples had decreased in length (mean decrease, 32.40%) and width (mean decrease, 34.21%) and increased in depth (mean increase, 54.95%). Tissue from the tibia had the most shrinkage in length and width and that from the neck had the least shrinkage. Inclusion of underlying muscle on thoracic skin samples did not affect the degree of change in dimensions. CONCLUSIONS AND CLINICAL RELEVANCE In this study, each step during processing from excision to formalin fixation and histologic processing induced changes in tissue dimensions, which were manifested principally as shrinkage in length and width and increase in depth. Most of the changes occured during histologic processing. Inclusion of muscle did not affect thoracic skin shrinkage. Shrinkage should be a consideration when interpreting surgical margins in clinical cases.
Afficher plus [+] Moins [-]