Affiner votre recherche
Résultats 1-10 de 101
Up in smoke: California's greenhouse gas reductions could be wiped out by 2020 wildfires
2022
Jerrett, Michael | Jina, Amir S. | Marlier, Miriam E.
In this short communication, we estimate that California's wildfire carbon dioxide equivalent (CO₂e) emissions from 2020 are approximately two times higher than California's total greenhouse gas (GHG) emission reductions since 2003. Without considering future vegetation regrowth, CO₂e emissions from the 2020 wildfires could be the second most important source in the state above either industry or electrical power generation. Regrowth may partly of fully occur over a long period, but due to exigencies of the climate crisis most of the regrowth will not occur quickly enough to avert greater than 1.5 degrees of warming. Global monetized damages caused by CO₂e from in 2020 wildfire emissions amount to some $7.1 billion USD. Our analysis suggests that significant societal benefits could accrue from larger investments in improved forest management and stricter controls on new development in fire-prone areas at the wildland-urban interface.
Afficher plus [+] Moins [-]Antibiotics degradation by UV/chlor(am)ine advanced oxidation processes: A comprehensive review
2022
Lu, Zedong | Ling, Yanchen | Sun, Wenjun | Liu, Chaoran | Mao, Ted | Ao, Xiuwei | Huang, Tianyin
Antibiotics are emerging contaminants in aquatic environments which pose serious risks to the ecological environment and human health. Advanced oxidation processes (AOPs) based on ultraviolet (UV) light have good application prospects for antibiotic degradation. As new and developing UV-AOPs, UV/chlorine and derived UV/chloramine processes have attracted increasing attention due to the production of highly reactive radicals (e.g., hydroxyl radical, reactive chlorine species, and reactive nitrogen species) and also because they can provide long-lasting disinfection. In this review, the main reaction pathways of radicals formed during the UV/chlor (am)ine process are proposed. The degradation efficiency, influencing factors, generation of disinfection by-products (DBPs), and changes in toxicity that occur during antibiotic degradation by UV/chlor (am)ine are reviewed. Based on the statistics and analysis of published results, the effects caused by energy consumption, defined as electrical energy per order (EE/O), increase in the following order: UV/chlorine < UV/peroxydisulfate (PDS)< UV/H₂O₂ < UV/persulfate (PS) < 265 nm and 285 nm UV-LED/chlorine (EE/O). Some inherent problems that affect the UV/chlor (am)ine processes and prospects for future research are proposed. The use of UV/chlor (am)ine AOPs is a rich field of research and has promising future applications, and this review provides a theoretical basis for that.
Afficher plus [+] Moins [-]A sequential utilization of the UV-A (365 nm) fluence rate for disinfection of water, contaminated with Legionella pneumophila and Legionelladumoffii
2022
Allahyari, Elaheh | Carraturo, Federica | De Risi, Arianna | Nappo, Antonio | Morelli, Michela | Cajora, Alessia | Guida, Marco
Legionella species are the etiological agent of Legionnaires' disease, a pathology easily contracted from water circuits and by the inhalation of aerosol droplets. This bacterium mainly proliferates in water: Legionella pneumophila is the most commonly isolated specie in water environments and consequently in water system, although further Legionella species have frequently been isolated, including Legionella dumoffii. The simultaneous presence of the two species in the water system can therefore lead to the simultaneous infection of several people, giving rise to harmful outbreaks. Ultraviolet inactivation of waterborne microorganisms offers a rapid and effective treatment technique and recently is getting more attention mostly to eliminate unsafe level of contamination. To tackle the issue, the inactivation of the two species of Legionella spp., namely L. pneumophila and L. dumoffii, by means of UV-A light emitting diodes (UV-A LED) system is explored. We used a commercially available UV-A LED at 365 nm wavelength, and the UV-A dose is given incrementally to the Legionellae with a concentration of 10⁶ CFU/mL in 0.9% NaCl (aq) solution. In this study, with a UV-A-dose of 1700 mJ/cm², the log-reduction of 3-log (99.9% inactivation) for L. pneumophila and 2.1-log (99.1% inactivation) for L. dumoffii of the contaminated water are achieved. The Electrical Energy per Order (EEO) is evaluated and showed this system is more economic and efficient in comparison with UV-C and UV-B LEDs. Following the support of this preliminary study with additional tests, aiming to validate the technology, we expect this device may be installed in water plants such as cooling systems or any water purification station in either industrial or home scales to reduce the risk of this infectious disease, preventing consumers' health.
Afficher plus [+] Moins [-]Electrochemical oxidation of the polycyclic aromatic hydrocarbons in polluted concrete of the residential buildings
2017
Aćimović, Danka D. | Karić, Slavko D. | Nikolić, Željka M. | Brdarić, Tanja P. | Tasić, Gvozden S. | Marčeta Kaninski, Milica P. | Nikolić, Vladimir M.
Polycyclic aromatic hydrocarbons (PAH) have been listed by the United States Environmental Protection Agency (US EPA) and by the European Community as priority environmental pollutants. The removal of PAHs from soils, sediments and waste water has attracted attention of scientists and engineers for several decades. Electrochemical oxidation of PAH compounds in water, is receiving increasing attention, due to its convenience and simplicity. In this study we performed electrochemical oxidation of 16 EPA PAHs mixture in 10% NaCl aqueous solution in potentiostatic conditions, at voltage 1 V. Decrease of concentration of some individual PAHs, up to 70% referred to their starting concentration, after 60 min of electrolysis, was confirmed by UPLC/PDA analysis. In further work investigation was extrapolated to in situ removal of PAHs from concrete, as the medium where, to our knowledge, such way of PAH removal has not been investigated before.High concentrations of PAH contamination occurred in the concrete structure of the residential buildings in Belgrade in 2014. Application of DC voltage of 50 V between nickel and stainless steel electrodes packed in the concrete wall, moisturized with the 10% NaCl solution, led to considerable removal of the pollutants by oxidation process throughout the concrete.
Afficher plus [+] Moins [-]A pilot study on remediation of sediments enriched by oyster farming wastes using granulated coal ash
2015
Yamamoto, T. | Kim, K.H. | Shirono, K.
In order to evaluate the ability of granulated coal ash (GCA), a byproduct of coal thermal electric power stations, to remove hydrogen sulfide from organically enriched sediments, a pilot study was carried out at oyster farming sites, where sediments were enriched with oyster feces and dead oysters. Concentration of hydrogen sulfide in the interstitial water of the sediment decreased to nearly zero in both experimental sites, whereas it remained over 0.2mg/l in the control site. Concentration of acid volatile sulfide (AVS) in the sediment also decreased significantly in both experimental sites, while remained over 0.4mg/g in the control site. Increases were observed in both the number of benthic microalgae species and the individual number of benthic animals in the surface sediments. This may have been due to the decrease in hydrogen sulfide.
Afficher plus [+] Moins [-]Numerical evaluation of the use of granulated coal ash to reduce an oxygen-deficient water mass
2016
Yamamoto, Hironori | Yamamoto, Tamiji | Mito, Yugo | Asaoka, Satoshi
Granulated coal ash (GCA), which is a by-product of coal thermal electric power stations, effectively decreases phosphate and hydrogen sulfide (H2S) concentrations in the pore water of coastal marine sediments. In this study, we developed a pelagic–benthic coupled ecosystem model to evaluate the effectiveness of GCA for diminishing the oxygen-deficient water mass formed in coastal bottom water of Hiroshima Bay in Japan. Numerical experiments revealed the application of GCA was effective for reducing the oxygen-deficient water masses, showing alleviation of the DO depletion in summer increased by 0.4–3mgl−1. The effect of H2S adsorption onto the GCA lasted for 5.25years in the case in which GCA was mixed with the sediment in a volume ratio of 1:1. The application of this new GCA-based environmental restoration technique could also make a substantial contribution to form a recycling-oriented society.
Afficher plus [+] Moins [-]Estimation of hydrogen sulfide removal efficiency with granulated coal ash applied to eutrophic marine sediment using a simplified simulation model
2015
Asaoka, Satoshi | Yamamoto, Tamiji | Yamamoto, Hironori | Okamura, Hideo | Hino, Kazutoshi | Nakamoto, Kenji | Saito, Tadashi
Hydrogen sulfide generated in eutrophic marine sediment is harmful for living organisms. It is therefore necessary to remove hydrogen sulfide from the sediment to restore benthic ecosystems. Previous studies revealed that granulated coal ash, which is a by-product of coal thermal electric power stations, could remove and oxidize hydrogen sulfide. In this study, we propose a simplified simulation model to estimate the hydrogen sulfide removal efficiency of granulated coal ash. Hydrogen sulfide concentrations in eutrophic marine sediment pore water with and without the application of granulated coal ash were calculated by the proposed model, and the outputs were compared with semi-field or field observation data. The model outputs reproduced the observed data well. Using the proposed model outputs, we suggest an optimum application dosage of granulated coal ash for remediating eutrophic marine sediment.
Afficher plus [+] Moins [-]Review of cooling techniques used to enhance the efficiency of photovoltaic power systems
2022
Sharaf, Mohamed | Yousef, Mohamed S. | Huzayyin, Ahmed S.
Photovoltaic (PV) panels are one of the most important solar energy sources used to convert the sun’s radiation falling on them into electrical power directly. Many factors affect the functioning of photovoltaic panels, including external factors and internal factors. External factors such as wind speed, incident radiation rate, ambient temperature, and dust accumulation on the PV cannot be controlled. The internal factors can be controlled, such as PV surface temperature. Some of the radiation falling on the surface of the PV cell turns into electricity, while the remainder of incident radiation is absorbed inside the PV cell. This, in turn, elevates its surface temperature. Undesirably, the higher panel temperature, the lower conversion performance, and lesser reliability over the long term occur. Hence, many cooling systems have been designed and investigated, aiming to effectively avoid the excessive temperature rise and enhance their efficiency. Many cooling methods are used to cool solar cells, such as passive cooling, active cooling, cooling with phase change materials (PCMs), and cooling with PCM with other additives such as nanoparticles or porous metal. In this work, the common methods utilized for cooling PV panels are reviewed and analyzed, focusing on the last methods, and summarizing all the researches that dealt with cooling PV solar cells with PCM and porous structures.
Afficher plus [+] Moins [-]Zirconia- and ceria-based electrolytes for fuel cell applications: critical advancements toward sustainable and clean energy production
2022
Maiti, Tushar Kanti | Majhi, Jagannath | Maiti, Subrata Kumar | Singh, Jitendra | Dixit, Prakhar | Rohilla, Tushita | Ghosh, Samaresh | Bhushan, Sakchi | Chattopadhyay, Sujay
Solid oxide fuel cells (SOFCs) are emerging as energy conversion devices for large-scale electrical power generation because of their high energy conversion efficiency, excellent ability to minimize air pollution, and high fuel flexibility. In this context, this critical review has focussed on the recent advancements in developing a suitable electrolyte for SOFCs which has been required for the commercialization of SOFC technology after emphasizing the literature from the prior studies. In particular, the significant developments in the field of solid oxide electrolytes for SOFCs, particularly zirconia- and ceria-based electrolytes, have been highlighted as important advancements toward the production of sustainable and clean energy. It has been reported that among various electrolyte materials, zirconia-based electrolytes have the potential to be utilized as the electrolyte in SOFC because of their high thermal stability, non-reducing nature, and high mechanical strength, along with acceptable oxygen ion conductivity. However, some studies have proved that the zirconia-based electrolytes are not suitable for low and intermediate-temperature working conditions because of their poor ionic conductivity to below 850 °C. On the other hand, ceria-based electrolytes are being investigated at a rapid pace as electrolytes for intermediate and low-temperature SOFCs due to their higher oxygen ion conductivity with good electrode compatibility, especially at lower temperatures than stabilized zirconia. In addition, the most emerging advancements in electrolyte materials have demonstrated that the intermediate temperature SOFCs as next-generation energy conversion technology have great potential for innumerable prospective applications.
Afficher plus [+] Moins [-]Performance enhancement of solar photovoltaic (PV) module using a novel flat plate (NFP) glass cover by reducing the effect of bird dropping (BD) settlement
2022
Sisodia, Anil Kumar | Mathur, Ramkumar
A massive bird dropping (BD) deposition on the common rectangular flat plate (RFP) of photovoltaic (PV) module is a matter of great concern in Western Rajasthan (WR) that diminish the overall energy production capacity of the system remarkably. In this research article, a prototype novel flat plate (NFP) design of a front glass cover of PV module is proposed to prevent the impact of BD settlement by the restriction of bird’s sitting/movement on the front glass cover. In this regard, the performance analysis of PV module with common RFP and newly designed NFP glass covers has been assessed at the different inclination β° (0–90). The BD accumulation onto the both glass covers was explored by the optical transmittance profiles at the different tilt angles, i.e., explained by bird movement on each flat glass surfaces. Consequently, a significant amount of output electric energy has been gained in NFP design rather than RFP corresponding to particular tilt regions TR I (0° ≤ β ≤ 25°), TR II (25° ≤ β ≤ 60°), and TR III (60° ≤ β ≤ 90°). According to the results achieved, an excellent level of improvement in average power loss, ~ 97.85%, corresponding to optimal TR (III) has been detected by employing NFP glass collector.
Afficher plus [+] Moins [-]