Affiner votre recherche
Résultats 1-10 de 13
Reactivity of adenosine triphosphatase adsorbed on nitrocellulose
2001
Momic, T. | Banjac, A. | Horvat, A. (Institut za nuklearna istrazivanja Vinca, Beograd (Yugoslavia). Laboratorija za molekularnu biologiju)
Possibilities of application of transmembrane enzymes as a biological component of a biosensor for water quality control and detection of toxical substances were performed. Synaptic plasma membranes (SPMs) were adsorbed on nitrocellulose filters. The adsorption of SPMs was followed by determination of the transmembrane enzyme Na,K-ATPase. The optimal conditions for SPM adsorption on nitrocellulose filters were determined: 25 microgram per nitrocellulose filter disc during 1 hour of incubation, on - 20 deg C. The ATPase activity of adsorbed SPM showed, that almost 30% of enzymic activity was detected on nitrocellulose filters in mentioned conditions. This results showed that adsorption of SPM on solid support enhancing enzymatic stability and enable its industrial and analytical application.
Afficher plus [+] Moins [-]Contribution of a submerged membrane bioreactor in the treatment of synthetic effluent contaminated by Bisphenol-A: Mechanism of BPA removal and membrane fouling
2013
Seyhi, Brahima | Drogui, Patrick | Buelna, Gerardo | Azaïs, Antonin | Heran, Marc
A submerged membrane bioreactor has been operated at the laboratory scale for the treatment of a synthetic effluent containing Bisphenol-A (BPA). COD, NH4–N, PO4–P and BPA were eliminated respectively, at 99%, 99%, 61% and 99%. The increase of volumetric loading rate from 0 to 21.6 g/m3/d did not affect the performance of the MBR system. However, the removal rate decreased rapidly when the BPA loading rate increased above 21.6 g/m3/d. The adsorption process of BPA on the biomass was very well described by Freundlich and Langmuir isotherms. Subsequently, biodegradation of BPA occurred and followed the first order kinetic reaction, with a constant rate of 1.13 ± 0.22 h−1. During treatment, membrane fouling was reversible in the first 84 h of filtration, and then became irreversible. The membrane fouling was mainly due to the accumulation of suspended solid and development of biofilm on the membrane surface.
Afficher plus [+] Moins [-]Predicting bioavailability of PAHs in field-contaminated soils by passive sampling with triolein embedded cellulose acetate membranes
2009
Tao, Yuqiang | Zhang, Shuzhen | Wang, Zijian | Christie, Peter
Triolein embedded cellulose acetate membrane (TECAM) was used for passive sampling of the fraction of naphthalene, phenanthrene, pyrene and benzo[a]pyrene in 18 field-contaminated soils. The sampling process of PAHs by TECAM fitted well with a first-order kinetics model and PAHs reached 95% of equilibrium in TECAM within 20 h. Concentrations of PAHs in TECAM (CTECAM) correlated well with the concentrations in soils (r2 = 0.693-0.962, p < 0.001). Furthermore, concentrations of PAHs determined in the soil solution were very close to the values estimated by CTECAM and the partition coefficient between TECAM and water (KTECAM-w). After lipid normalization nearly 1:1 relationships were observed between PAH concentrations in TECAMs and earthworms exposed to the soils (r2 = 0.591–0.824, n = 18, p < 0.01). These results suggest that TECAM can be a useful tool to predict bioavailability of PAHs in field-contaminated soils.
Afficher plus [+] Moins [-]Mobile passive samplers: Concept for a novel mode of exposure
2011
Allan, Ian J. | Nilsson, Hans C. | Tjensvoll, Ingrid | Bradshaw, Clare | Næs, Kristoffer
Integrative passive sampling with devices such as semipermeable membrane devices generally relies on rigs for month-long static exposures in water. We evaluate here whether mobile exposures of passive samplers can provide reliable estimates of dissolved contaminant concentrations. Mobile exposures were obtained by towing samplers fastened to the end of a benthic trawl net. Significant and reproducible absorption of polycyclic aromatic hydrocarbons during 5 h-long deployments was made possible by high sampling rates resulting from high water turbulences during towing at 1.2–1.5 knots. Sampling rates (72–215 L d⁻¹) estimated from the dissipation of performance reference compounds were supported by in situ calibration with samplers exposed for a 30 days in the vicinity of the test site. Higher fluoranthene and pyrene absorption in samplers exposed to the trawling-induced sediment plume could be attributed to desorption from re-suspended sediments. This mode of exposure has the potential to be used in monitoring programmes.
Afficher plus [+] Moins [-]The use of nanoparticles in polymeric and ceramic membrane structures: Review of manufacturing procedures and performance improvement for water treatment
2010
Membrane separations are powerful tools for various applications, including wastewater treatment and the removal of contaminants from drinking water. The performance of membranes is mainly limited by material properties. Recently, successful attempts have been made to add nanoparticles or nanotubes to polymers in membrane synthesis, with particle sizes ranging from 4 nm up to 100 nm. Ceramic membranes have been fabricated with catalytic nanoparticles for synergistic effects on the membrane performance. Breakthrough effects that have been reported in the field of water and wastewater treatment include fouling mitigation, improvement of permeate quality and flux enhancement. Nanomaterials that have been used include titania, alumina, silica, silver and many others. This paper reviews the role of engineered nanomaterials in (pressure driven) membrane technology for water treatment, to be applied in drinking water production and wastewater recycling. Benefits and drawbacks are described, which should be taken into account in further studies on potential risks related to release of nanoparticles into the environment.
Afficher plus [+] Moins [-]Long-term air monitoring of organochlorine pesticides using Semi Permeable Membrane Devices (SPMDs) in the Alps
2009
Levy, W. | Henkelmann, B. | Pfister, G. | Bernhöft, S. | Kirchner, M. | Jakobi, G. | Bassan, R. | Kräuchi, N. | Schramm, K.W.
Atmospheric sampling of organochlorine pesticides (OCPs) was conducted using Semi Permeable Membrane Devices (SPMDs) deployed in the Alps at different altitudinal transects for two consecutive exposure periods of half a year and a third simultaneous year-long period. Along all the altitude profiles, the sequestered amounts of OCPs increased in general with altitude. SPMDs were still working as kinetic samplers after half a year for the majority of the OCPs. However, compounds with the lowest octanol-air partition coefficient (Koa), reached equilibrium within six months. This change in the SPMD uptake was determined for the temperature gradient along the altitude profile influencing Koa, OCPs availability in the gaseous phase, and SPMD performance. In sum, it seems two effects are working in parallel along the altitude profiles: the change in SPMD performance and the different availability of OCPs along the altitudinal transects determined by their compound properties and concentrations in air. SPMDs were in different uptake stages regarding OCPs, as they were influenced by the temperature (season, triolein state, and altitude) and Koa.
Afficher plus [+] Moins [-]Removal of arsenic from contaminated groundwater by solar-driven membrane distillation
2010
Manna, Ajay K. | Sen, Mou | Martin, Andrew R. | Pal, Parimal
Experimental investigations were carried out on removal of arsenic from contaminated groundwater by employing a new flat-sheet cross flow membrane module fitted with a hydrophobic polyvinylidenefluoride (PVDF) microfiltration membrane. The new design of the solar-driven membrane module in direct contact membrane distillation (DCMD) configuration successfully produced almost 100 per cent arsenic-free water from contaminated groundwater in a largely fouling-free operation while permitting high fluxes under reduced temperature polarization. For a feed flow rate of 0.120 m3/h, the 0.13 μm PVDF membrane yielded a high flux of 74 kg/(m2 h) at a feed water temperature of 40 °C and, 95 kg/m2 h at a feed water temperature of 60 °C. The encouraging results show that the design could be effectively exploited in the vast arsenic-affected rural areas of South-East Asian countries blessed with abundant sunlight particularly during the critical dry season. Solar-driven membrane distillation has the potential of removing arsenic from contaminated groundwater.
Afficher plus [+] Moins [-]Precipitation softening: a pretreatment process for seawater desalination
2014
Ayoub, George M. | Zayyat, Ramez M. | Al-Hindi, Mahmoud
Reduction of membrane fouling in reverse osmosis systems and elimination of scaling of heat transfer surfaces in thermal plants are a major challenge in the desalination of seawater. Precipitation softening has the potential of eliminating the major fouling and scaling species in seawater desalination plants, thus allowing thermal plants to operate at higher top brine temperatures and membrane plants to operate at a reduced risk of fouling, leading to lower desalinated water costs. This work evaluated the use of precipitation softening as a pretreatment step for seawater desalination. The effectiveness of the process in removing several scale-inducing materials such as calcium, magnesium, silica, and boron was investigated under variable conditions of temperature and pH. The treatment process was also applied to seawater spiked with other known fouling species such as iron and bacteria to determine the efficiency of removal. The results of this work show that precipitation softening at a pH of 11 leads to complete elimination of calcium, silica, and bacteria; to very high removal efficiencies of magnesium and iron (99.6 and 99.2 %, respectively); and to a reasonably good removal efficiency of boron (61 %).
Afficher plus [+] Moins [-]Removal of non-steroidal anti-inflammatory drugs ibuprofen and ketoprofen from water by emulsion liquid membrane
2014
Dâas, Attef | Hamdaoui, Oualid
In this work, the removal of the worldwide non-steroidal anti-inflammatory drugs ibuprofen (IBP) and ketoprofen (KTP) by emulsion liquid membrane (ELM) was carried out. An ELM system is made up of hexane as diluent, Span 80 as the surfactant and sodium carbonate as the inner aqueous solution. Effect of experimental conditions that affect the extraction of IBP such as surfactant concentration, emulsification time, sulfuric acid concentration in external phase, acid type in external phase, internal phase concentration, type of internal phase, stirring speed, volume ratio of internal phase to membrane phase, treatment ratio, IBP initial concentration, diluent type and salt was investigated. The obtained results showed that by appropriate selection of the operational parameters, it was possible to extract nearly all of IBP molecules from the feed solution even in the presence of high concentration of salt. Under optimum operating conditions, the efficiencies of IBP removal from distilled water (99.3 %), natural mineral water (97.3 %) and sea water (94.0 %) were comparable, which shows that the ELM treatment process represents a very interesting advanced separation process for the removal of IBP from complex matrices such as natural and sea waters. Under the optimized experimental conditions, approximately 97.4 % KTP was removed in less than 20 min of contact time.
Afficher plus [+] Moins [-]