Affiner votre recherche
Résultats 1561-1570 de 2,513
Effect of Fenton treatment on the aquatic toxicity of bisphenol A in different water matrices Texte intégral
2014
Arslan-Alaton, Idil | Aytac, Ece | Kusk, Kresten Ole
Battery tests serve as integral tools to decide whether a treatment process is ecotoxicologically safe or not. In the present study, a battery of toxicity tests was employed to elucidate the toxicity of the potential endocrine-disrupting pollutant bisphenol A (BPA) and its advanced oxidation products. For this purpose, BPA was subjected to Fenton treatment in the growth medium of the test organisms employed as well as in real lake water. Treatment results indicated that BPA removals were fast and complete within less than a minute, whereas total organic carbon (TOC) removals were rather incomplete, speaking for the accumulation of refractory degradation products. The presence of chloride and/or natural organic matter influenced H₂O₂ consumption rates and the treatment performance of the Fenton’s reagent as well. The sensitivity of the selected test organisms for BPA and its Fenton treatment products in different water matrices was found in the following decreasing order: the freshwater microalgae (Pseudokirchneriella subcapitata) > the freshwater cladoceran (Daphnia magna) > marine photobacteria (Vibrio fischeri).
Afficher plus [+] Moins [-]Risk of laryngeal and nasopharyngeal cancer associated with arsenic and cadmium in the Tunisian population Texte intégral
2014
Khlifi, Rim | Olmedo, Pablo | Gil, Fernando | Feki-Tounsi, Molka | Hammami, Bouthaina | Rebai, Ahmed | Hamza-Chaffai, Amel
Chronic exposure to heavy metals has long been recognized as being capable of increasing head and neck cancer (HNC) incidence, such as laryngeal (LC) and nasopharyngeal (NPC), among exposed human populations. The aim of the present study was to evaluate the concentrations of arsenic (As) and cadmium (Cd) in the blood of 145 patients (LC and NPC) and 351 controls in order to establish a potential relationship between these factors and the occurrence of LC and NPC. Mean blood levels of As and Cd in patients (5.67 and 3.51 μg/L, respectively) were significantly higher than those of controls (1.57 and 0.74 μg/L, respectively). The blood levels of As and Cd were mostly significantly higher than those of controls (p < 0.05) after controlling the other risk factors of HNC including tobacco smoking and chewing, and alcohol drinking. Cd levels in blood increase significantly with the number of occupational exposure years for patients (p < 0.05). However, seafood was not found to be contributing as an exposure source. Among these risk factors, smoking (>30 pack years) and occupational exposure (>20 years) presented the most significant association with HNC (OR = 10.22 and 10.38, respectively, p < 0.001). Cd level in blood sample of cases that are occupationally exposed/tobacco users (smokers and chewers) were higher than that of non-occupationally exposed/nontobacco users (p < 0.001). The logistic regression model illustrated that HNC (LC + NPC) was significantly associated with blood levels of As (OR = 2.41, p < 0.001) and Cd (OR = 4.95, p < 0.001).
Afficher plus [+] Moins [-]Degradation of the potential rodent contraceptive quinestrol and elimination of its estrogenic activity in soil and water Texte intégral
2014
Zhang, Quan | Wang, Cui | Liu, Wanpeng | Qu, Jiapeng | Liu, Ming | Zhang, Yanming | Zhao, Meirong
Quinestrol has shown potential for use in the fertility control of the plateau pika population of the Qinghai–Tibet Plateau. However, the environmental safety and fate of this compound are still obscure. Our study investigated degradation of quinestrol in a local soil and aquatic system for the first time. The results indicate that the degradation of quinestrol follows first-order kinetics in both soil and water, with a dissipation half-life of approximately 16.0 days in local soil. Microbial activity heavily influenced the degradation of quinestrol, with 41.2 % removal in non-sterile soil comparing to 4.8 % removal in sterile soil after incubation of 10 days. The half-lives in neutral water (pH 7.4) were 0.75 h when exposed to UV light (λ = 365 nm) whereas they became 2.63 h when exposed to visible light (λ > 400 nm). Acidic conditions facilitated quinestrol degradation in water with shorter half-lives of 1.04 and 1.47 h in pH 4.0 and pH 5.0 solutions, respectively. Moreover, both the soil and water treatment systems efficiently eliminated the estrogenic activity of quinestrol. Results presented herein clarify the complete degradation of quinestrol in a relatively short time. The ecological and environmental safety of this compound needs further investigation.
Afficher plus [+] Moins [-]Photolysis of atrazine in aqueous solution: role of process variables and reactive oxygen species Texte intégral
2014
Silva, Marcela Prado | dos Santos Batista, Ana Paula | Borrely, Sueli Ivone | Silva, Vanessa Honda Ogihara | Teixeira, Antonio Carlos Silva Costa
Photochemical advanced oxidation processes have been considered for the treatment of water and wastewater containing the herbicide atrazine (ATZ), a possible human carcinogen and endocrine disruptor. In this study, we investigated the effects of the photon emission rate and initial concentration on ATZ photolysis at 254 nm, an issue not usually detailed in literature. Moreover, the role of reactive oxygen species (ROS) is discussed. Photon emission rates in the range 0.87 × 10¹⁸–3.6 × 10¹⁸ photons L⁻¹ s⁻¹ and [ATZ]₀ = 5 and 20 mg L⁻¹ were used. The results showed more than 65 % of ATZ removal after 30 min. ATZ photolysis followed apparent first-order kinetics with k values and percent removals decreasing with increasing herbicide initial concentration. A fivefold linear increase in specific degradation rate constants with photon emission rate was observed. Also, regardless the presence of persistent degradation products, toxicity was efficiently removed after 60-min exposure to UV radiation. Experiments confirmed a noticeable contribution of singlet oxygen and radical species to atrazine degradation during photolysis. These results may help understand the behavior of atrazine in different UV-driven photochemical degradation treatment processes.
Afficher plus [+] Moins [-]Fe(III)–EDDS complex in Fenton and photo-Fenton processes: from the radical formation to the degradation of a target compound Texte intégral
2014
Wu, Yanlin | Passananti, Monica | Brigante, Marcello | Dong, Wenbo | Mailhot, Gilles
The present work compares the efficiency of homogenous Fenton and photo-Fenton processes in the presence of Fe(III)–EDDS complex under different experimental conditions. 4-tert-Butylphenol (4-t-BP), which is one of the endocrine disrupting chemicals, was used as a model pollutant to investigate the Fenton and photo-Fenton application. The efficiency of homogenous photo-Fenton process was significantly much higher than homogenous Fenton process, which is due to the rapid formation of Fe²⁺ under UV irradiation of the iron complex and the photochemical formation of HO• from the photolysis of the complex Fe(III)–EDDS. Through the degradation of 4-t-BP, the effect of Fe(III)–EDDS concentration, H₂O₂ concentration, pH, and oxygen was investigated in both processes. Such trend was also correlated with pH calculating the polychromatic Fe²⁺ quantum yield formation at pH 4.0, 6.0, and 8.6. The results showed that at high Fe(III)–EDDS and H₂O₂ concentrations, a negative effect was found. By the way, the Fenton process was found to be enhanced at basic pH. These results can be very useful for the use and optimization of such iron complex in water treatment process as function of different physico-chemical conditions.
Afficher plus [+] Moins [-]Treatment of a wastewater from a pesticide manufacture by combined coagulation and Fenton oxidation Texte intégral
2014
Pliego, G. | Zazo, J. A. | Pariente, M. I. | Rodríguez, I. | Petre, A. L. | Leton, P. | Garcia, J.
The treatment of a non-biodegradable agrochemical wastewater has been studied by coupling of preliminary coagulation—flocculation step and further Fenton oxidation. High percentages of chemical oxygen demand (COD) removal (up to 58 %) were achieved in a first step using polyferric chloride as coagulant. This reduced significantly the amount of H₂O₂ required in the further Fenton oxidation. Using the stoichiometric amount relative to COD around 80 % of the remaining organic load was mineralized. The combined treatment allowed achieving the regional discharge limits of ecotoxicity at a cost substantially lower than the solution used so far where these wastewaters are managed as hazardous wastes.
Afficher plus [+] Moins [-]Microbial biotransformation of aryl sulfanylpentafluorides Texte intégral
2014
Kavanagh, Emma | Winn, Michael | Gabhann, Cliona Nic | O’Connor, Neil K. | Beier, Petr | Murphy, Cormac D.
We report, for the first time, the biotransformation of potential pollutants bearing the pentafluorosulfanyl (SF₅-) functional group in a fungus and bacteria. Cunninghamella elegans transformed p-methoxy phenyl SF₅via demethylation; Pseudomonas knackmussii and P. pseudoalcaligenes KF707 transformed amino-, hydroxyamino- and diamino- substituted phenyl SF₅, forming the N-acetylated derivatives as the main product. Cell-free extract of Streptomyces griseus transformed 4-amino-3-hydroxy-phenyl SF₅to the N-acetylated derivative in the presence of acetyl CoA, confirming that an N-acetyltransferase is responsible for the bacterial biotransformations. Approximately 25 % of drugs and 30 % of agrochemicals contain fluorine, and the trifluoromethyl group is a prominent feature of many of these since it improves lipophilicity and stability. The pentafluorosulfanyl substituent is seen as an improvement on the trifluoromethyl group and research efforts are underway to develop synthetic methods to incorporate this moiety into biologically active compounds. It is important to determine the potential environmental impact of these compounds, including the potential biotransformation reactions that may occur when they are exposed to microorganisms.
Afficher plus [+] Moins [-]Factorial design analysis for COD removal from landfill leachate by photoassisted Fered-Fenton process Texte intégral
2014
Wu, Xiaogang | Zhang, Hui | Li, Yanli | Zhang, Daobin | Li, Xianwang
The Fered-Fenton process has been shown to be an effective method for leachate treatment, but it still faces problems of inadequate regeneration of ferrous ion. However, the use of the photoassisted Fered-Fenton process could overcome this difficulty and improve the efficiency of chemical oxygen demand (COD) removal since photoassisted Fered-Fenton process induces the production of hydroxyl radicals from the regeneration of ferrous ions and the reaction of hydrogen peroxide with UV light. As there are so many operating parameters in photoassisted Fered-Fenton process, it is necessary to develop a mathematical model in order to produce the most economical process. In the present study, a factorial design was carried out to evaluate leachate treatment by photoassisted Fered-Fenton process. The influence of the following variables: H₂O₂concentration, Fe²⁺concentration, current density, and initial pH in the photoassisted Fered-Fenton process was investigated by measuring COD removal efficiencies after 60-min reaction. The relationship between COD removal and the most significant independent variables was established by means of an experimental design. The H₂O₂concentration, Fe²⁺concentration, initial pH, and the interaction effect between current density and initial pH were all significant factors. The factorial design models were derived based on the COD removal efficiency results and the models fit the data well.
Afficher plus [+] Moins [-]Emergy-based comparative analysis on industrial clusters: economic and technological development zone of Shenyang area, China Texte intégral
2014
Liu, Zhe | Geng, Yong | Zhang, Pan | Dong, Huijuan | Liu, Zuoxi
In China, local governments of many areas prefer to give priority to the development of heavy industrial clusters in pursuit of high value of gross domestic production (GDP) growth to get political achievements, which usually results in higher costs from ecological degradation and environmental pollution. Therefore, effective methods and reasonable evaluation system are urgently needed to evaluate the overall efficiency of industrial clusters. Emergy methods links economic and ecological systems together, which can evaluate the contribution of ecological products and services as well as the load placed on environmental systems. This method has been successfully applied in many case studies of ecosystem but seldom in industrial clusters. This study applied the methodology of emergy analysis to perform the efficiency of industrial clusters through a series of emergy-based indices as well as the proposed indicators. A case study of Shenyang Economic Technological Development Area (SETDA) was investigated to show the emergy method’s practical potential to evaluate industrial clusters to inform environmental policy making. The results of our study showed that the industrial cluster of electric equipment and electronic manufacturing produced the most economic value and had the highest efficiency of energy utilization among the four industrial clusters. However, the sustainability index of the industrial cluster of food and beverage processing was better than the other industrial clusters.
Afficher plus [+] Moins [-]Analyzing sediment dissolved oxygen based on microprofile modeling Texte intégral
2014
Wang, Chao | Shan, Baoqing | Zhang, Hong | Rong, Nan
Sediment plays a key role in controlling the oxygen demand of aquatic systems. The reaction rate, penetration depth, and flux across the sediment–water interface (SWI) are important factors in sediment oxygen consumption. However, there were few methods to collect these data until recently. In this study, methods were developed to simulate the oxygen microprofile and calculate the sediment oxygen consumption rate, oxygen penetration depth, and oxygen flux across the SWI. We constructed a sediment oxygen measuring system using an oxygen microelectrode and a control device. The simulation equations were derived from both zero and first-order kinetic models, while the penetration depth and the oxygen flux were calculated from the simulation results. The method was tested on four prepared sediment samples. Decreases in dissolved oxygen in surface sediment were clearly detected by the microelectrode. The modeled data were a good fit for the observed data (R² > 0.95), and zero-order kinetics were more suitable than first-order kinetics. The values for penetration depth (1.3–3.9 mm) and oxygen fluxes (0.061–0.114 mg/cm²/day) calculated by our methods are comparable with those from other studies.
Afficher plus [+] Moins [-]