Affiner votre recherche
Résultats 721-730 de 26,567
Coffee water use in agroforestry system with rubber trees Uso da água em sistema agroflorestal com café e seringueira Texte intégral
2008
Ciro Abbud Righi | Aureny Maria Pereira Lunz | Marcos Silveira Bernardes | Carlos Rodrigues Pereira | Edson Roberto Teramoto | José Laercio Favarin
Water uptake and use by plants are essentially energy processes that can be largely modified by percentage of soil cover, plant type; foliage area and its distribution; phenological stage and several environmental factors. Coffee trees (Coffea arabica - cv. Obatã IAC 1669-20) in Agrforestry System (AFS) spaced 3.4x0.9m apart, were planted inside and along rows of 12- year-old rubber trees (Hevea spp.) in Piracicaba-SP, Brazil (22 42'30" S, 47 38'00" W - altitude: 546m). Sap flow of one-year-old coffee plants exposed to 35; 45; 80; 95 and 100% of total solar radiation was estimated by the heat balance technique (Dynamax Inc.). Coffee plants under shade showed greater water loss per unit of incident irradiance. On the other hand, plants in monocrop (full sun) had the least water loss per unit of incident irradiance. For the evaluated positions average water use was (gH2O.m-2Leaf area.MJ-1): 64.71; 67.75; 25.89; 33.54; 27.11 in Dec./2002 and 97.14; 72.50; 40.70; 32.78; 26.13 in Feb./2003. This fact may be attributed to the higher stomata sensitivity of the coffee plants under more illuminated conditions, thus plants under full sun presented the highest water use efficiency. Express transpiration by leaf mass can be a means to access plant adaptation to the various environments, which is inaccessible when the approach is made by leaf area.<br>A absorção e uso da água pelas plantas são processos essencialmente energéticos que podem ser grandemente modificados pela porcentagem de cobertura do solo, tipo de plantas, área foliar e sua distribuição, estágio fenológico e diversos fatores ambientais. Cafeeiros (Coffea arabica - cv. Obatã IAC 1669-20) em Sistema Agroflorestal (AFS) espaçados de 3.4 x 0.9 m foram plantados dentro e ao lado de um seringal de 12 anos de idade (Hevea spp.) em Piracicaba, SP, Brasil (22 42'30"S, 47 38'00" W - altitude: 546 m). O fluxo de seiva dos cafeeiros com 1 ano de idade expostos a 35, 45, 80, 95 e 100% da radiação solar foi estimado pela técnica do balanço de calor (Dynamax Inc.). Cafeeiros sombreados sofreram a maior perda de água por unidade de radiação incidente. No entanto, as plantas em monocultivo (pleno sol) apresentaram a menor perda de água por unidade de radiação incidente. Nas distâncias avaliadas, o uso médio de água foi (gH2O.m-2área foliar.MJ-1): 64,71; 67,75; 25,89; 33,54; e 27,11 em dez./2002 e 97,14; 72,50; 40,70; 32,78; e 26,13 em fev./2003. Tal fato pode ser atribuído à maior sensibilidade estomatal dos cafeeiros sob condições de maior iluminação, o que faz que plantas a pleno sol apresentem eficiência de uso da água mais elevada. Expressar a transpiração por massa de folha pode ser um meio de verificar a adaptação das plantas aos diversos ambientes, a qual é inacessível quando realizado por área foliar.
Afficher plus [+] Moins [-]Frações de fosfato em resrvatíorios de água em Lavras - MG Fractions of phosphate in water bodies in Lavras - MG Texte intégral
2007
Regilene Angélica da Silva Souza | Suzana Romeiro de Araújo | Valquíria Aparecida Mendes de Jesus | João José Marques | Nilton Curi | Mário Cesar Guerreiro
Frações de fosfato em resrvatíorios de água em Lavras - MG Fractions of phosphate in water bodies in Lavras - MG Texte intégral
2007
Regilene Angélica da Silva Souza | Suzana Romeiro de Araújo | Valquíria Aparecida Mendes de Jesus | João José Marques | Nilton Curi | Mário Cesar Guerreiro
O presente estudo teve como objetivo determinar os teores e as frações de P presentes nos corpos d'água de reservatórios no Campus da Universidade Federal de Lavras, verificando a eventual presença de condições de eutrofização. Foram selecionados oito reservatórios dentro do Campus, representando as condições de uso e manejo do solo. As amostragens foram realizadas mensalmente, com início em janeiro e término em dezembro de 2004. Foram quantificados os níveis de P, nas seguintes formas: ortofosfato solúvel (OPS), ortofosfato total (OPT), P solúvel total (PST), P total (PT), P particulado total (PPT), P não reativo solúvel (PNRS), P não reativo particulado (PNRP) e o ortofosfato particulado (OPP). Foram também avaliados os parâmetros: pH, condutividade eletrolítica, Ca, Mg, Na, K, NO-3, NO-2 e NH+4 . Os limites de detecção do método e os limites de quantificação foram determinados. Os valores encontrados de OPS para os corpos d água sempre estiveram abaixo do permitido pela Resolução CONAMA 357/05. No entanto, outras frações de P apresentaram teores elevados, refletindo as precipitações pluviométricas e as condições do solo. Esses teores mais elevados têm caráter momentâneo e, no geral, estes corpos d'água podem ser considerados de excelente qualidade quanto à presença de P. O manejo do solo dentro do Campus da UFLA e o tratamento aplicado a efluentes e águas residuárias de granjas e estábulos mostraram, no geral, serem adequados, não oferecendo grandes riscos de eutrofização aos cursos d'água que cortam o campus.<br>The objective of this study was to evaluate the contents and fractions of P in water bodies at the Campus of the Federal University of Lavras to verify the occurrence of eutrophication. Eight artificial lakes were chosen, representing the conditions of soil use and management in the campus. The samples were collected monthly from January to December 2004. The levels of P in the following forms were assessed: soluble orthophosphate (OPS), total orthophosphate (OPT), total soluble P (PST), total P (PT), total particulate P (PPT), soluble non-reactive P (PNRS), non-reactive particulate P (PNRP), and total particulate orthophosphate (OPP). The pH, electrolytic conductivity, Ca, Mg, Na, K, NO-3, NH+4 and NO-2 were also evaluated. The contents of OPS were below those allowed by the CONAMA 357/05 Resolution. Nevertheless, other fractions of P were present in high contents, reflecting the soil conditions and the rainfall. Episodes of high P contents were momentary. In general, these water bodies may be considered of excellent quality concerning the P contents. Soil management in the Campus and the treatment applied to effluents and waste waters appear to be suitable avoiding eutrophication.
Afficher plus [+] Moins [-]Frações de fosfato em resrvatíorios de água em Lavras - MG | Fractions of phosphate in water bodies in Lavras - MG Texte intégral
2015 | 2007
Souza, Regilene Angélica da Silva | Araújo, Suzana Romeiro de | Jesus, Valquíria Aparecida Mendes de | Marques, João José | Curi, Nilton | Guerreiro, Mário Cesar
The objective of this study was to evaluate the contents and fractions of P in water bodies at the Campus of the Federal University of Lavras to verify the occurrence of eutrophication. Eight artificial lakes were chosen, representing the conditions of soil use and management in the campus. The samples were collected monthly from January to December 2004. The levels of P in the following forms were assessed: soluble orthophosphate (OPS), total orthophosphate (OPT), total soluble P (PST), total P (PT), total particulate P (PPT), soluble non-reactive P (PNRS), non-reactive particulate P (PNRP), and total particulate orthophosphate (OPP). The pH, electrolytic conductivity, Ca, Mg, Na, K, NO–3, NH+4 and NO–2 were also evaluated. The contents of OPS were below those allowed by the CONAMA 357/05 Resolution. Nevertheless, other fractions of P were present in high contents, reflecting the soil conditions and the rainfall. Episodes of high P contents were momentary. In general, these water bodies may be considered of excellent quality concerning the P contents. Soil management in the Campus and the treatment applied to effluents and waste waters appear to be suitable avoiding eutrophication. | O presente estudo teve como objetivo determinar os teores e as frações de P presentes nos corpos d'água de reservatórios no Campus da Universidade Federal de Lavras, verificando a eventual presença de condições de eutrofização. Foram selecionados oito reservatórios dentro do Campus, representando as condições de uso e manejo do solo. As amostragens foram realizadas mensalmente, com início em janeiro e término em dezembro de 2004. Foram quantificados os níveis de P, nas seguintes formas: ortofosfato solúvel (OPS), ortofosfato total (OPT), P solúvel total (PST), P total (PT), P particulado total (PPT), P não reativo solúvel (PNRS), P não reativo particulado (PNRP) e o ortofosfato particulado (OPP). Foram também avaliados os parâmetros: pH, condutividade eletrolítica, Ca, Mg, Na, K, NO-3, NO-2 e NH+4 . Os limites de detecção do método e os limites de quantificação foram determinados. Os valores encontrados de OPS para os corpos d água sempre estiveram abaixo do permitido pela Resolução CONAMA 357/05. No entanto, outras frações de P apresentaram teores elevados, refletindo as precipitações pluviométricas e as condições do solo. Esses teores mais elevados têm caráter momentâneo e, no geral, estes corpos d'água podem ser considerados de excelente qualidade quanto à presença de P. O manejo do solo dentro do Campus da UFLA e o tratamento aplicado a efluentes e águas residuárias de granjas e estábulos mostraram, no geral, serem adequados, não oferecendo grandes riscos de eutrofização aos cursos d'água que cortam o campus.
Afficher plus [+] Moins [-]Frações de fosfato em resrvatíorios de água em Lavras - MG Texte intégral
2007
Souza, Regilene Angélica da Silva(Universidade Federal do Rio Grande do Sul Faculdade de Agronomia) | Araújo, Suzana Romeiro de(USP ESALQ) | Jesus, Valquíria Aparecida Mendes de(Universidade Federal de Lavras Departamento de Ciência do Solo) | Marques, João José(Universidade Federal de Lavras Departamento de Ciência do Solo) | Curi, Nilton(Universidade Federal de Lavras Departamento de Ciência do Solo) | Guerreiro, Mário Cesar(Universidade Federal de Lavras Departamento de Química)
O presente estudo teve como objetivo determinar os teores e as frações de P presentes nos corpos d'água de reservatórios no Campus da Universidade Federal de Lavras, verificando a eventual presença de condições de eutrofização. Foram selecionados oito reservatórios dentro do Campus, representando as condições de uso e manejo do solo. As amostragens foram realizadas mensalmente, com início em janeiro e término em dezembro de 2004. Foram quantificados os níveis de P, nas seguintes formas: ortofosfato solúvel (OPS), ortofosfato total (OPT), P solúvel total (PST), P total (PT), P particulado total (PPT), P não reativo solúvel (PNRS), P não reativo particulado (PNRP) e o ortofosfato particulado (OPP). Foram também avaliados os parâmetros: pH, condutividade eletrolítica, Ca, Mg, Na, K, NO-3, NO-2 e NH+4 . Os limites de detecção do método e os limites de quantificação foram determinados. Os valores encontrados de OPS para os corpos d água sempre estiveram abaixo do permitido pela Resolução CONAMA 357/05. No entanto, outras frações de P apresentaram teores elevados, refletindo as precipitações pluviométricas e as condições do solo. Esses teores mais elevados têm caráter momentâneo e, no geral, estes corpos d'água podem ser considerados de excelente qualidade quanto à presença de P. O manejo do solo dentro do Campus da UFLA e o tratamento aplicado a efluentes e águas residuárias de granjas e estábulos mostraram, no geral, serem adequados, não oferecendo grandes riscos de eutrofização aos cursos d'água que cortam o campus. | The objective of this study was to evaluate the contents and fractions of P in water bodies at the Campus of the Federal University of Lavras to verify the occurrence of eutrophication. Eight artificial lakes were chosen, representing the conditions of soil use and management in the campus. The samples were collected monthly from January to December 2004. The levels of P in the following forms were assessed: soluble orthophosphate (OPS), total orthophosphate (OPT), total soluble P (PST), total P (PT), total particulate P (PPT), soluble non-reactive P (PNRS), non-reactive particulate P (PNRP), and total particulate orthophosphate (OPP). The pH, electrolytic conductivity, Ca, Mg, Na, K, NO-3, NH+4 and NO-2 were also evaluated. The contents of OPS were below those allowed by the CONAMA 357/05 Resolution. Nevertheless, other fractions of P were present in high contents, reflecting the soil conditions and the rainfall. Episodes of high P contents were momentary. In general, these water bodies may be considered of excellent quality concerning the P contents. Soil management in the Campus and the treatment applied to effluents and waste waters appear to be suitable avoiding eutrophication.
Afficher plus [+] Moins [-]Savanna woodland soil micromorphology related to water retention Micromorfologia de solo sob cerradão em relação à retenção de água Texte intégral
2007
Carlos Eduardo Pinto Juhász | Miguel Cooper | Patrícia Ribeiro Cursi | André Oppitz Ketzer | Raul Shiso Toma
The limiting factors of the Brazilian savanna physical environment have been largely discussed. Soil morphology is fundamental to understand the behavior of soil water flow, soil physical properties and soil-landscape relationships. The aim of this study is to relate soil micro and macromorphologic attributes to soil water retention on a toposequence under native savanna woodland (cerradão) in a permanent plot of 320 m <FONT FACE=Symbol>´</FONT> 320 m installed in Assis, SP, Brazil. Samples collected at five points within the toposequence were used to determine the soil macroporosity by means of image analyses, estimated total porosity, chemical analysis, particle size distribution analysis and soil water retention. From the summit down to the footslope, the soils were classified as Rhodic Haplustox, Typic Haplustox and Epiaquic Haplustult, presenting a gradual color transition and a sandy loam texture. In the surface horizons, the higher organic matter content and the high total macroporosity determined a lower soil bulk density and lower water retention. In the Oxisols, the high soil macroporosity results from the packing of microaggregates in the oxic horizon. In the Ultisol, the lower total porosity in the deeper horizons resulted in a higher water retention and an imperfect water drainage. The water retention conditions on the slope influenced the morphological differences in soil color and structure. The low water retention on the surface and oxic horizons, conditioned by the high total macroporosity, is one of the factors that may define the vegetal pattern of the savanna woodland within the permanent plot.<br>Os fatores limitantes do ambiente físico do Cerrado têm sido muito discutidos. Porém, o detalhamento da morfologia do solo torna-se fundamental à compreensão do seu funcionamento físico-hídrico e sua relação com a paisagem. O objetivo deste estudo foi relacionar os atributos macro e micromorfológicos à retenção de água no solo em uma toposseqüência sob cerradão em uma parcela permanente de 320 <FONT FACE=Symbol>´</FONT> 320 m, instalada em Assis, SP. Amostras coletadas em cinco pontos distribuídos na toposseqüência foram utilizadas para determinar a macroporosidade do solo por análise de imagens, porosidade total estimada, análise química, granulometria e retenção de água no solo. De montante a jusante, os solos foram classificados como Latossolo Vermelho, Latossolo Vermelho-Amarelo, Latossolo Amarelo e Gleissolo Háplico, apresentando uma transição gradual de cor e textura franco-arenosa. No horizonte de superfície, o maior teor de matéria orgânica e a elevada macroporosidade total determinaram menor densidade do solo e baixa retenção de água. Nos Latossolos, a microestrutura do solo consistiu principalmente em aglomerados de microagregados, ocasionando uma elevada macroporosidade no horizonte diagnóstico. No Gleissolo, a menor porosidade total nos horizontes mais profundos resultou em uma maior retenção de água e drenagem imperfeita. As diferenças morfológicas de cor e estrutura do solo foram influenciadas pelas condições de retenção de água na vertente. A baixa retenção de água nos horizontes de solo superficiais e latossólicos, condicionada pela elevada macroporosidade total, é um dos fatores que pode definir o padrão vegetacional de cerradão na parcela permanente.
Afficher plus [+] Moins [-]Métodos analíticos no controle microbiológico da água para consumo humano Analithical methods for water microbiological control for human consumtion Texte intégral
2006
Janine Maria Pereira Ramos Bettega | Maria Rosa Machado | Mayra Presibella | Grazielle Baniski | Carlos de Almeida Barbosa
Métodos analíticos no controle microbiológico da água para consumo humano Analithical methods for water microbiological control for human consumtion Texte intégral
2006
Janine Maria Pereira Ramos Bettega | Maria Rosa Machado | Mayra Presibella | Grazielle Baniski | Carlos de Almeida Barbosa
A fim de realizar a quantificação de coliformes totais e fecais no decorrer das etapas de tratamento da água captada pela Companhia de Saneamento do Paraná (SANEPAR) Curitiba-PR, foram utilizadas três técnicas de análise microbiológica: (1) a técnica oficial preconizada pela Vigilância Sanitária, (2) Kit "A", (3) Kit "B". As metodologias foram validadas através de controles positivos e negativos. Os métodos utilizados apresentaram resultados extremamente homogêneos nas amostras pré-tratadas e também quando as amostras haviam passado pelos processos de purificação, porém, algumas discrepâncias entre os métodos avaliados foram detectadas em etapas intermediárias do tratamento da água. A utilização de Kits no controle microbiológico da água é muito prática porque elimina as etapas de preparação e esterilização dos meios de cultura em laboratório, porém deve-se analisar cuidadosamente o custo-benefício, bem como a sensibilidade e especificidade dos produtos disponíveis no mercado. O Kit "B" emprega um método enzimático, ao invés do método tradicional e Kit "A", que utilizam ambos: a turvação e formação de gás para a detecção o crescimento bacteriano. O kit " B" apresentou resultados similares aos outros dois métodos, mas com as vantagens de apresentar resultados extremamente claros e levar a metade do tempo para a obtenção dos resultados.<br>In order to carry out the quantification of total and fecal coliforms in elapsing of the stages of water treatment by SANEPAR, Paraná State, three different techniques of microbiological analysis had been used: (1) the official technique praised by the Sanitary Monitoring; (2) Kit "A" and (3) Kit "B". The three methodologies of the water microbiological analysis had been validated through positive and negative controls. The used methods had presented extremely homogeneous results when the samples were contaminated and also when the samples had passed through the purification processes, however, some discrepancies among the evaluated methods had been detected in intermediate stages of the water treatment. The use of commercial Kits in water microbiological control is very practical because it eliminates the preparation and sterilization stages of the culture media in laboratory, however, it is necessary to analise carefully the cost-bennefit, sensibility and specifity of disposable products in market. The Kit "B" utilizes an enzymatic method, instead the tradicional technique and Kit "A" use both: the dim and gas formation to detect bacterial growth. The Kit "B" had showed similar results to the other two techniques, but with the advantages of presenting extreme clear results and take a half of time in the results obtention.
Afficher plus [+] Moins [-]Métodos analíticos no controle microbiológico da água para consumo humano | Analithical methods for water microbiological control for human consumtion Texte intégral
2015 | 2006
Bettega, Janine Maria Pereira Ramos | Machado, Maria Rosa | Presibella, Mayra | Baniski, Grazielle | Barbosa, Carlos de Almeida
In order to carry out the quantification of total and fecal coliforms in elapsing of the stages of water treatment by SANEPAR, Paraná State, three different techniques of microbiological analysis had been used: (1) the official technique praised by the Sanitary Monitoring; (2) Kit "A" and (3) Kit "B". The three methodologies of the water microbiological analysis had been validated through positive and negative controls. The used methods had presented extremely homogeneous results when the samples were contaminated and also when the samples had passed through the purification processes, however, some discrepancies among the evaluated methods had been detected in intermediate stages of the water treatment. The use of commercial Kits in water microbiological control is very practical because it eliminates the preparation and sterilization stages of the culture media in laboratory, however, it is necessary to analise carefully the cost-bennefit, sensibility and specifity of disposable products in market. The Kit "B" utilizes an enzymatic method, instead the tradicional technique and Kit "A" use both: the dim and gas formation to detect bacterial growth. The Kit "B" had showed similar results to the other two techniques, but with the advantages of presenting extreme clear results and take a half of time in the results obtention. | A fim de realizar a quantificação de coliformes totais e fecais no decorrer das etapas de tratamento da água captada pela Companhia de Saneamento do Paraná (SANEPAR) Curitiba-PR, foram utilizadas três técnicas de análise microbiológica: (1) a técnica oficial preconizada pela Vigilância Sanitária, (2) Kit "A", (3) Kit "B". As metodologias foram validadas através de controles positivos e negativos. Os métodos utilizados apresentaram resultados extremamente homogêneos nas amostras pré-tratadas e também quando as amostras haviam passado pelos processos de purificação, porém, algumas discrepâncias entre os métodos avaliados foram detectadas em etapas intermediárias do tratamento da água. A utilização de Kits no controle microbiológico da água é muito prática porque elimina as etapas de preparação e esterilização dos meios de cultura em laboratório, porém deve-se analisar cuidadosamente o custo-benefício, bem como a sensibilidade e especificidade dos produtos disponíveis no mercado. O Kit "B" emprega um método enzimático, ao invés do método tradicional e Kit "A", que utilizam ambos: a turvação e formação de gás para a detecção o crescimento bacteriano. O kit " B" apresentou resultados similares aos outros dois métodos, mas com as vantagens de apresentar resultados extremamente claros e levar a metade do tempo para a obtenção dos resultados.
Afficher plus [+] Moins [-]Métodos analíticos no controle microbiológico da água para consumo humano Texte intégral
2006
Bettega, Janine Maria Pereira Ramos(Universidade Tuiuti do Paraná) | Machado, Maria Rosa(Universidade Tuiuti do Paraná) | Presibella, Mayra(Universidade Tuiuti do Paraná) | Baniski, Grazielle(Universidade Tuiuti do Paraná) | Barbosa, Carlos de Almeida(Universidade Tuiuti do Paraná Laboratório de Microbiologia)
A fim de realizar a quantificação de coliformes totais e fecais no decorrer das etapas de tratamento da água captada pela Companhia de Saneamento do Paraná (SANEPAR) Curitiba-PR, foram utilizadas três técnicas de análise microbiológica: (1) a técnica oficial preconizada pela Vigilância Sanitária, (2) Kit "A", (3) Kit "B". As metodologias foram validadas através de controles positivos e negativos. Os métodos utilizados apresentaram resultados extremamente homogêneos nas amostras pré-tratadas e também quando as amostras haviam passado pelos processos de purificação, porém, algumas discrepâncias entre os métodos avaliados foram detectadas em etapas intermediárias do tratamento da água. A utilização de Kits no controle microbiológico da água é muito prática porque elimina as etapas de preparação e esterilização dos meios de cultura em laboratório, porém deve-se analisar cuidadosamente o custo-benefício, bem como a sensibilidade e especificidade dos produtos disponíveis no mercado. O Kit "B" emprega um método enzimático, ao invés do método tradicional e Kit "A", que utilizam ambos: a turvação e formação de gás para a detecção o crescimento bacteriano. O kit " B" apresentou resultados similares aos outros dois métodos, mas com as vantagens de apresentar resultados extremamente claros e levar a metade do tempo para a obtenção dos resultados. | In order to carry out the quantification of total and fecal coliforms in elapsing of the stages of water treatment by SANEPAR, Paraná State, three different techniques of microbiological analysis had been used: (1) the official technique praised by the Sanitary Monitoring; (2) Kit "A" and (3) Kit "B". The three methodologies of the water microbiological analysis had been validated through positive and negative controls. The used methods had presented extremely homogeneous results when the samples were contaminated and also when the samples had passed through the purification processes, however, some discrepancies among the evaluated methods had been detected in intermediate stages of the water treatment. The use of commercial Kits in water microbiological control is very practical because it eliminates the preparation and sterilization stages of the culture media in laboratory, however, it is necessary to analise carefully the cost-bennefit, sensibility and specifity of disposable products in market. The Kit "B" utilizes an enzymatic method, instead the tradicional technique and Kit "A" use both: the dim and gas formation to detect bacterial growth. The Kit "B" had showed similar results to the other two techniques, but with the advantages of presenting extreme clear results and take a half of time in the results obtention.
Afficher plus [+] Moins [-]Consumo de água pela cultura do crisântemo cultivada em ambiente protegido Water requirement by chrysanthemum cultivated under greenhouse conditions Texte intégral
2005
Joelma R. D. Pereira | Jacinto de A. Carvalho | Douglas S. Miguel | Márcio J. de Santana
Consumo de água pela cultura do crisântemo cultivada em ambiente protegido Water requirement by chrysanthemum cultivated under greenhouse conditions Texte intégral
2005
Joelma R. D. Pereira | Jacinto de A. Carvalho | Douglas S. Miguel | Márcio J. de Santana
Com o objetivo de determinar o consumo de água pela cultura do crisântemo, ao longo do seu ciclo de desenvolvimento, conduziu-se um experimento em ambiente protegido, na Universidade Federal de Lavras - MG, com as cultivares Kátia e Bi Time. O delineamento experimental foi o inteiramente casualizado, em esquema fatorial, com duas cultivares e duas freqüências de irrigação, com oito repetições, sendo o manejo da irrigação feito utilizando-se do método da pesagem. O consumo de água entre irrigações foi obtido pela pesagem dos vasos. Instalou-se na área experimental um tanque Classe A, para obter a evaporação e posterior correlação com o consumo hídrico das cultivares. Verificou-se que não houve diferença significativa do consumo quando as cultivares foram irrigadas uma e duas vezes ao dia. Observou-se que as cultivares possuem consumo diferenciado segundo seus estádios de desenvolvimento. O consumo médio de água, ao longo do ciclo, para a freqüência de irrigação de uma e duas vezes ao dia, da cultivar Kátia, foi de 118 e 108 mL dia-1, e da cultivar Bi Time, foi de 98 e 113 mL dia-1, respectivamente.<br>With the objective of determining the chrysanthemum water consumption, an experiment was carried out at the Universidade Federal de Lavras, MG, Brazil, under greenhouse condition, with two chrysanthemums cultivars, Kátia and Bi Time. A completely randomized experimental design in a factorial outline, with eight replications, two cultivars and two irrigation frequencies were used. Irrigation scheduling was based on pot plant weight. The water consumption between irrigations was obtained by weighting the pot. A class A tank, was used to obtain the evaporation and subsequent correlation with the crop water consumption. It was verified that there was not significant difference of water requirement when the cultivars were irrigated once and twice day. It was observed that the cultivars presented differentiated water requirement according to the development stage. Along the cycle, the average water consumption, for once and twice day irrigation, for cultivar Kátia was 118 and 108 mL day-1 and for the cultivar Bi Time was 98 and 113 mL day-1, respectively.
Afficher plus [+] Moins [-]Consumo de água pela cultura do crisântemo cultivada em ambiente protegido Texte intégral
2005
Pereira, Joelma R. D.(UFLA DEG) | Carvalho, Jacinto de A.(Departamento de Engenharia) | Miguel, Douglas S.(Departamento de Engenharia) | Santana, Márcio J. de(Departamento de Engenharia)
Com o objetivo de determinar o consumo de água pela cultura do crisântemo, ao longo do seu ciclo de desenvolvimento, conduziu-se um experimento em ambiente protegido, na Universidade Federal de Lavras - MG, com as cultivares Kátia e Bi Time. O delineamento experimental foi o inteiramente casualizado, em esquema fatorial, com duas cultivares e duas freqüências de irrigação, com oito repetições, sendo o manejo da irrigação feito utilizando-se do método da pesagem. O consumo de água entre irrigações foi obtido pela pesagem dos vasos. Instalou-se na área experimental um tanque Classe A, para obter a evaporação e posterior correlação com o consumo hídrico das cultivares. Verificou-se que não houve diferença significativa do consumo quando as cultivares foram irrigadas uma e duas vezes ao dia. Observou-se que as cultivares possuem consumo diferenciado segundo seus estádios de desenvolvimento. O consumo médio de água, ao longo do ciclo, para a freqüência de irrigação de uma e duas vezes ao dia, da cultivar Kátia, foi de 118 e 108 mL dia-1, e da cultivar Bi Time, foi de 98 e 113 mL dia-1, respectivamente. | With the objective of determining the chrysanthemum water consumption, an experiment was carried out at the Universidade Federal de Lavras, MG, Brazil, under greenhouse condition, with two chrysanthemums cultivars, Kátia and Bi Time. A completely randomized experimental design in a factorial outline, with eight replications, two cultivars and two irrigation frequencies were used. Irrigation scheduling was based on pot plant weight. The water consumption between irrigations was obtained by weighting the pot. A class A tank, was used to obtain the evaporation and subsequent correlation with the crop water consumption. It was verified that there was not significant difference of water requirement when the cultivars were irrigated once and twice day. It was observed that the cultivars presented differentiated water requirement according to the development stage. Along the cycle, the average water consumption, for once and twice day irrigation, for cultivar Kátia was 118 and 108 mL day-1 and for the cultivar Bi Time was 98 and 113 mL day-1, respectively.
Afficher plus [+] Moins [-][Water use efficiency in the greenhouses from Almería [Spain]] | Eficiencia del uso del agua en los invernaderos de Almería
2004
Fernández, M.D. (Estación Experimental "Las Palmerillas", El Ejido, Almería (España))
Análise operacional de um sistema fotovoltaico de bombeamento de água Operational analysis of a photovoltaic water pumping (PV) system Texte intégral
2004
Evandro M. Kolling | Samuel N. M. de Souza | Reinaldo P. Ricieri | Silvio C. Sampaio | Rivanildo Dallacort
Análise operacional de um sistema fotovoltaico de bombeamento de água Operational analysis of a photovoltaic water pumping (PV) system Texte intégral
2004
Evandro M. Kolling | Samuel N. M. de Souza | Reinaldo P. Ricieri | Silvio C. Sampaio | Rivanildo Dallacort
O bombeamento de água é uma das atividades mais difundidas quanto ao emprego da energia solar fotovoltaica. Porém, apesar de se apresentar como alternativa interessante, o alto custo, a baixa eficiência dos sistemas e os projetos inadequados restringem sua aplicação. O uso racional, baseado na utilização mais eficiente de seus equipamentos, está vinculado ao conhecimento do comportamento operacional desses sistemas. No presente trabalho, teve-se o objetivo de avaliar o comportamento de um sistema fotovoltaico de bombeamento de água diretamente acoplado, sob diferentes condições de irradiância solar, por meio da montagem de uma bancada de testes, submetendo-o a diferentes alturas manométricas e determinando-se a vazão fornecida. A análise dos resultados permitiu estabelecer um modelo de regressão para estimativa de vazão do sistema em função da irradiância e altura manométrica. Concluiu-se que a potência gerada pelo painel e a vazão fornecida pela motobomba estão diretamente relacionadas à irradiância solar e à altura manométrica e influenciam na eficiência do sistema. A máxima eficiência do painel foi de 8%, 39% para a motobomba e 2,3% na interação dos componentes.<br>The pumping of water is one of the activities most diffused to the employment of the photovoltaic solar energy, in spite of coming as an interesting alternative, the high cost and it lowers efficiency of the systems with the inadequate projects, still restricts its application. The rational use, based on the most efficient use of its equipments is linked to the knowledge of the operational behavior of these systems. The present work objectified to evaluate the operational behavior of a photovoltaic water pumping directly coupled operating in different conditions of solar irradiance, by means of the assembly of supported tests, submitting to different manometer elevation and determining the supplied rate flux of water. The analysis of the results allowed to determine a regression model for flux of water estimation as function of irradiance and manometer elevation. Was concluded that the power generated by the array and the rate flux supplied by the motor-pump is directly related to the solar irradiance. The maximum efficiency of the array was of 8%, 39% for the motor-pump and, 2.3% in the interaction of the components in the system.
Afficher plus [+] Moins [-]Análise operacional de um sistema fotovoltaico de bombeamento de água Texte intégral
2004
Kolling, Evandro M.(Cooperativa Agrícola de Campo Mourão) | Souza, Samuel N. M. de(UNIOESTE) | Ricieri, Reinaldo P.(UNIOESTE) | Sampaio, Silvio C.(UNIOESTE) | Dallacort, Rivanildo(UEM)
O bombeamento de água é uma das atividades mais difundidas quanto ao emprego da energia solar fotovoltaica. Porém, apesar de se apresentar como alternativa interessante, o alto custo, a baixa eficiência dos sistemas e os projetos inadequados restringem sua aplicação. O uso racional, baseado na utilização mais eficiente de seus equipamentos, está vinculado ao conhecimento do comportamento operacional desses sistemas. No presente trabalho, teve-se o objetivo de avaliar o comportamento de um sistema fotovoltaico de bombeamento de água diretamente acoplado, sob diferentes condições de irradiância solar, por meio da montagem de uma bancada de testes, submetendo-o a diferentes alturas manométricas e determinando-se a vazão fornecida. A análise dos resultados permitiu estabelecer um modelo de regressão para estimativa de vazão do sistema em função da irradiância e altura manométrica. Concluiu-se que a potência gerada pelo painel e a vazão fornecida pela motobomba estão diretamente relacionadas à irradiância solar e à altura manométrica e influenciam na eficiência do sistema. A máxima eficiência do painel foi de 8%, 39% para a motobomba e 2,3% na interação dos componentes. | The pumping of water is one of the activities most diffused to the employment of the photovoltaic solar energy, in spite of coming as an interesting alternative, the high cost and it lowers efficiency of the systems with the inadequate projects, still restricts its application. The rational use, based on the most efficient use of its equipments is linked to the knowledge of the operational behavior of these systems. The present work objectified to evaluate the operational behavior of a photovoltaic water pumping directly coupled operating in different conditions of solar irradiance, by means of the assembly of supported tests, submitting to different manometer elevation and determining the supplied rate flux of water. The analysis of the results allowed to determine a regression model for flux of water estimation as function of irradiance and manometer elevation. Was concluded that the power generated by the array and the rate flux supplied by the motor-pump is directly related to the solar irradiance. The maximum efficiency of the array was of 8%, 39% for the motor-pump and, 2.3% in the interaction of the components in the system.
Afficher plus [+] Moins [-]Simulação numérica de movimento de água em solo não-saturado Numerical simulation of water movement in an unsaturated soil Texte intégral
2003
Paulo C. Oliveira | José L. Lima
Simulação numérica de movimento de água em solo não-saturado Numerical simulation of water movement in an unsaturated soil Texte intégral
2003
Paulo C. Oliveira | José L. Lima
Neste trabalho, o método de volumes finitos foi utilizado com esquema de discretização mais elaborado, chamado Flux-Spline, a fim de simular numericamente problemas unidimensionais não lineares de infiltração de água em solo hidraulicamente homogêneo não-saturado. Problemas-teste foram apresentados e resolvidos para alguns valores e combinações dos dois parâmetros adimensionais de governo, para demonstrar as vantagens do novo esquema quando comparado ao tradicional esquema de diferença central. Os resultados obtidos mostraram melhor desempenho do esquema quando comparado à diferença central, em todos os casos simulados, demonstrando que o esquema pode ser recomendado para a simulação numérica de movimentação de água em solo hidraulicamente homogêneo não-saturado.<br>In this work the finite volume method was used with an improved scheme of discretization called Flux-Spline, for the numerical study of non-linear problems in uni-dimensional water flow in hydraulically homogeneous unsaturated soil. Test-problems were presented and resolved to some values and combinations of the two governing non-dimensional parameters to demonstrate the advantages of the new scheme when compared to the traditional central difference scheme. The results obtained showed a better performance of the new scheme when compared to the central difference scheme in all simulated cases, demonstrating that the scheme can be recommended for numerical simulation of water movement in hydraulically homogeneous unsatured soil.
Afficher plus [+] Moins [-]Możliwości usprawniania procesów zarządzania w łańcuchu żywnościowym na przykładzie Produktu Lokalnego z Małopolski Texte intégral
2017
Nowakowska-Grunt, Joanna | Kiełbasa, Barbara
The main goal of the article was to discuss the importance of introducing short supply chains in the context of minimizing the adverse effects of traditional supply chains. The paper presents a case study of the Local Product of Malopolska as an example of good practice. When analyzing the concept of shortened supply chains, some significant benefits for agricultural producers, consumers and the region can be noticed. Reduction of the food chain links brings more benefits to farmers, and can contribute to avoiding the Forrester`s effect repercussions. Short food chains can be used to promote a region, as well as organic, local or traditional products. Despite the weaknesses of the local dimension of this concept, the idea contributes to sustainable development, which links economic goals, with social and environmental objectives. Presented reflections do not exhaust the subject, but only signal a topic that requires a holistic approach to the subject. / Synopsis. Celem artykułu była analiza i ocena znaczenia krótkich łańcuchów dostaw w kontekście minimalizowania niekorzystnych zjawisk występujących w klasycznych łańcuchach dostaw. W pracy przedstawiono studium przypadku Produkt Lokalny z Małopolski, jako przykład dobrych praktyk. Analizując koncepcję skróconych łańcuchów dostaw można zauważyć istotne korzyści dla producentów rolnych, dla konsumentów, a także dla regionu. Ograniczenie ogniw łańcucha żywnościowego przynosi więcej korzyści rolnikowi, a dzięki skróceniu łańcucha do minimum można uniknąć reperkusji efektu Forrestera. Krótkie łańcuchy żywnościowe można zastosować do promocji regionu, produkcji ekologicznej, czy też produktów lokalnych i tradycyjnych. Mimo słabych stron jakim jest lokalny wymiar omawianej koncepcji, idea ta przyczynia się do realizacji założeń rozwoju zrównoważonego, która łączy cele ekonomiczne, z celami społecznymi i ochroną środowiska. Przedstawione rozważania nie wyczerpują tematu, a jedynie sygnalizują zagadnienie, które wymaga całościowego podejścia do tej tematyki.
Afficher plus [+] Moins [-]Możliwości usprawniania procesów zarządzania w łańcuchu żywnościowym na przykładzie Produktu Lokalnego z Małopolski Texte intégral
Joanna Nowakowska-Grunt | Barbara Kiełbasa
Celem artykułu była analiza i ocena znaczenia krótkich łańcuchów dostaw w kontekście minimalizowania niekorzystnych zjawisk występujących w klasycznych łańcuchach dostaw. W pracy przedstawiono studium przypadku Produkt Lokalny z Małopolski, jako przykład dobrych praktyk. Analizując koncepcję skróconych łańcuchów dostaw można zauważyć istotne korzyści dla producentów rolnych, dla konsumentów, a także dla regionu. Ograniczenie ogniw łańcucha żywnościowego przynosi więcej korzyści rolnikowi, a dzięki skróceniu łańcucha do minimum można uniknąć reperkusji efektu Forrestera. Krótkie łańcuchy żywnościowe można zastosować do promocji regionu, produkcji ekologicznej, czy też produktów lokalnych i tradycyjnych. Mimo słabych stron jakim jest lokalny wymiar omawianej koncepcji, idea ta przyczynia się do realizacji założeń rozwoju zrównoważonego, która łączy cele ekonomiczne, z celami społecznymi i ochroną środowiska. Przedstawione rozważania nie wyczerpują tematu, a jedynie sygnalizują zagadnienie, które wymaga całościowego podejścia do tej tematyki. | The main goal of the article was to discuss the importance of introducing short supply chains in the context of minimizing the adverse effects of traditional supply chains. The paper presents a case study of the Local Product of Malopolska as an example of good practice. When analyzing the concept of shortened supply chains, some significant benefits for agricultural producers, consumers and the region can be noticed. Reduction of the food chain links brings more benefits to farmers, and can contribute to avoiding the Forrester`s effect repercussions. Short food chains can be used to promote a region, as well as organic, local or traditional products. Despite the weaknesses of the local dimension of this concept, the idea contributes to sustainable development, which links economic goals, with social and environmental objectives. Presented reflections do not exhaust the subject, but only signal a topic that requires a holistic approach to the subject. | łańcuch żywnościowy, zarządzanie, zagrożenia, korzyści, produkt lokalny | food chain, management, constraints, benefits, local product | 13 | 155-165 | 2
Afficher plus [+] Moins [-]Crescimento de cultivares de melão amarelo irrigadas com água salina Growth of yellow melon cultivars irrigated with saline water Texte intégral
2003
Renato D. Alencar | Francisco de Q. Porto Filho | José F. de Medeiros | José S. de Holanda | Vânia C. N. Porto | Miguel Ferreira Neto
Crescimento de cultivares de melão amarelo irrigadas com água salina Growth of yellow melon cultivars irrigated with saline water Texte intégral
2003
Renato D. Alencar | Francisco de Q. Porto Filho | José F. de Medeiros | José S. de Holanda | Vânia C. N. Porto | Miguel Ferreira Neto
Neste trabalho, estudaram-se os efeitos de cinco níveis (N) de salinidade da água de irrigação (1,51; 2,79; 3,93; 5,15 e 7,22 dS m-1), no desenvolvimento inicial de duas cultivares de melão amarelo (Gold mine e AF646). O cultivo foi realizado na horta do Departamento de Fitotecnia da ESAM, localizada no município de Mossoró, RN, no período de 4 de novembro a 12 de dezembro de 1998, em recipientes plásticos com capacidade para 9 L, conduzidos ao ar livre, tendo como substrato Argissolo vermelho-amarelo eutrófico abrupto do horizonte Ap1, utilizando-se o delineamento em blocos inteiramente casualizados arranjados no esquema fatorial 2x5, com três repetições. As características: peso seco da parte aérea, área foliar e salinidade média e final do solo, foram avaliadas mediante análise de variância (teste F) e estudo de regressão. As cultivares Gold mine e AF646 apresentaram comportamento semelhante quanto a tolerância à salinidade da água de irrigação, com perda de fitomassa seca da parte aérea (FSPA) de 6,8% por aumento unitário da condutividade elétrica na água de irrigação. O comportamento da área foliar foi similar ao da FSPA. Observou-se efeito linear e quadrático da salinidade da água de irrigação sobre a salinidade média e final do solo, respectivamente.<br>The effect of five irrigation water salinity levels (N: 1.51, 2.79, 3.93, 5.15 and 7,22 dS m-1), on initial development of two yellow melon cultivars (Gold mine and AF646) was studied. The trial was conducted under field conditions in an orchard belonging to Department of Phytotechnic - ESAM, at Mossoró in the State of RIo Grande do Norte, Brazil, during the period of November 4 to December 12, 1998. Plastic pots with 9 L capacity filled with Alfisol soil (horizon Ap1) were used. Experimental design was a completely randomized block in a factorial scheme, with three replications. Shoot dry matter, leaf area, mean soil salinity and final soil salinity were evaluated through variance and regression analysis. Salinity tolerance was similar for Gold mine and AF646, with a loss of 6.8% of shoot dry matter for unit increase of electrical conductivity of irrigation water. A similar behavior was observed for leaf area. Irrigation water salinity induced linear effect on mean soil salinity and quadratic effect on final soil salinity.
Afficher plus [+] Moins [-]Crescimento de cultivares de melão amarelo irrigadas com água salina Texte intégral
2003
Alencar, Renato D. | Porto Filho, Francisco de Q.(Escola Superior de Agricultura de Mossoró) | Medeiros, José F. de(Escola Superior de Agricultura de Mossoró) | Holanda, José S. de(EMBRAPA ,Empresa de Pesquisa Agropecuária do Rio Grande do Norte S/A) | Porto, Vânia C. N. | Ferreira Neto, Miguel(Empresa de Pesquisa Agropecuária do Rio Grande do Norte S/A)
Neste trabalho, estudaram-se os efeitos de cinco níveis (N) de salinidade da água de irrigação (1,51; 2,79; 3,93; 5,15 e 7,22 dS m-1), no desenvolvimento inicial de duas cultivares de melão amarelo (Gold mine e AF646). O cultivo foi realizado na horta do Departamento de Fitotecnia da ESAM, localizada no município de Mossoró, RN, no período de 4 de novembro a 12 de dezembro de 1998, em recipientes plásticos com capacidade para 9 L, conduzidos ao ar livre, tendo como substrato Argissolo vermelho-amarelo eutrófico abrupto do horizonte Ap1, utilizando-se o delineamento em blocos inteiramente casualizados arranjados no esquema fatorial 2x5, com três repetições. As características: peso seco da parte aérea, área foliar e salinidade média e final do solo, foram avaliadas mediante análise de variância (teste F) e estudo de regressão. As cultivares Gold mine e AF646 apresentaram comportamento semelhante quanto a tolerância à salinidade da água de irrigação, com perda de fitomassa seca da parte aérea (FSPA) de 6,8% por aumento unitário da condutividade elétrica na água de irrigação. O comportamento da área foliar foi similar ao da FSPA. Observou-se efeito linear e quadrático da salinidade da água de irrigação sobre a salinidade média e final do solo, respectivamente. | The effect of five irrigation water salinity levels (N: 1.51, 2.79, 3.93, 5.15 and 7,22 dS m-1), on initial development of two yellow melon cultivars (Gold mine and AF646) was studied. The trial was conducted under field conditions in an orchard belonging to Department of Phytotechnic - ESAM, at Mossoró in the State of RIo Grande do Norte, Brazil, during the period of November 4 to December 12, 1998. Plastic pots with 9 L capacity filled with Alfisol soil (horizon Ap1) were used. Experimental design was a completely randomized block in a factorial scheme, with three replications. Shoot dry matter, leaf area, mean soil salinity and final soil salinity were evaluated through variance and regression analysis. Salinity tolerance was similar for Gold mine and AF646, with a loss of 6.8% of shoot dry matter for unit increase of electrical conductivity of irrigation water. A similar behavior was observed for leaf area. Irrigation water salinity induced linear effect on mean soil salinity and quadratic effect on final soil salinity.
Afficher plus [+] Moins [-]Problemas operativos en el manejo del agua en distritos De Riego | Operative problems in water management in irrigation districts
2002
Mejia Saenz, E. | Palacios Velez, E. | Exebio Garcia, A. | Santos Hernandez, A.L.
In Mexico, water resources, apart from being limited, are badly distributed; on the coastal plain, with the exception of the Peninsula of Baja California and Sonora, there is an abundance of water, while in the rest of the country, it is scarce. With the transfer of the large irrigation districts to user organizations, it was intended that these districts become operationally and economically efficient organizations. In this way, decision-making passed from global planning, which covered an entire irrigation district, to fractioned planning, in which a small irrigation module is responsible for the administration of the water resource. Undoubtedly, the scarceness of this resource, together with the high demand of the agricultural sector and the low fees, is producing pressure for a change in the policies for management of this resource. In the management of the sources, it is not convenient to extract more water from the reservoirs than the average available volume; an additional volume generates less benefit, both economically and operationally, than what would be generated if it were stored for a dry year. In the case of the network, the deteriorated state of the infrastructure propitiates losses by leakage, infiltration in unlined ditches and inefficient water control in the channels. In the case of water management in the field delivery network, it is necessary to define actions to encourage the volumetric quotas and, in this aspect, the support of the government is essential; this means "political will," which could permit a considerable increase in the availability of water and, as a consequence, higher productivity of soil and water resources, as well as increased agricultural production and better incomes for the producers.
Afficher plus [+] Moins [-]