Electroretinogram and visual-evoked potential measurements in sheep
1991
Strain, G.M. | Claxton, M.S. | Prescott-Mathews, J.S. | LaPhand, D.J.
Electroretinogram (ERG) and visual-evoked potential (VEP) recordings were taken from ten Suffolk-cross sheep. Stimuli for VEP were 1.5 flashes of white light/s; ERG stimuli were single flashes. The ERG measurements of the a and b wave latencies and a-to-b amplitude were measured between the lower eyelid and the vertex, with ground on the nuchal crest. The VEP after monocular stimulation were measured between the nuchal crest and the interorbital line, with ground on the vertex. Measurements consisted of the latencies to seven alternating positive and negative peaks P1, N1 P2, N2, P3, N3 and P4, and six amplitudes, P1-N1, N1-P2, P2-N2, N2-P3, P3-N3 and N3-P4. Average latencies for the a and b waves were 13.6 and 28.2 ms; the mean ab amplitude was 131.68 micromole. Average latencies for the seven VEP peaks were 35.0, 43.1, 52.8, 64.1, 74.5, 90.4 and 112.2 ms. Mean amplitudes ranged from 3.90 to 8.29 microV.
Показать больше [+] Меньше [-]Ключевые слова АГРОВОК
Библиографическая информация
Эту запись предоставил National Agricultural Library