Determination of picogram quantities of chlortoluron in soil samples by luminol–chitosan chemiluminescence system
2014
Li, Yajuan | Zhang, Jingjing | Xiong, Xunyu | Luo, Kai | Guo, Jie | Shen, Minxia | Wang, Jiajia | Song, Zhenghua
Based on the enhancing effect of chitosan (CS) on luminol-dissolved oxygen chemiluminescence (CL) reaction, a flow injection (FI) luminol–CS CL system was established. It was found that the increase of CL intensity was proportional to the concentrations of CS ranging from 0.7 to 10.0 μmol l⁻¹. In the presence of chlortoluron (CTU), the CL intensity of luminol–CS system could be obviously inhibited and the decrements of CL intensity were linearly proportional to the logarithm of CTU concentrations ranging from 0.01 to 70.0 ng ml⁻¹, giving the limit of detection 3.0 pg ml⁻¹ (3σ). At a flow rate of 2.0 ml min⁻¹, the whole process including sampling and washing could be accomplished within 36 s, offering a sample throughput of 100 h⁻¹. The proposed FI–CL method was successfully applied to the determination of CTU in soil samples with recoveries ranging from 95.0 % to 105.3 % and the relative standard deviations (RSDs) of less than 4.0 %.
Показать больше [+] Меньше [-]Ключевые слова АГРОВОК
Библиографическая информация