Sampling and analysis of volatile organic compounds in air using a dualsorbent trap
2000
Mastrogiacomo, A. R. | Pierini, E. | Sampaolo, L.
A dualsorbent trap containing graphitized carbon blacks was used for the collection of volatile and semi-volatile organic pollutants from the atmosphere of different workplaces and from an above-ground parking lot. The method proved to be sensitive, simple and reliable.Thermal desorption and solvent extraction methods followed by GC-MS analysis were employed.