Simulation comparison of evaporative pads and fogging on air temperatures inside a growing swine building
2006
Panagakis, P. | Axaopoulos, P.
Evaporative pads and fogging were compared with regards to resulting air temperatures inside a growing swine building and reduction of apparent growing swine heat stress. Four strategies were studied via simulation, namely: strategy 'a' = no cooling, strategy 'b' = use of evaporative pads, strategy 'c' = use of fogging with the same amount of water evaporating as within the evaporative pads, and strategy 'd' = use of fogging with the necessary water evaporating so as to result in the same intensity of heat stress as strategy 'b'. Indices such as the THI, the number of hours that the THI was above 85, and the duration and intensity of heat stress were used. Among all, strategy 'b' was considered the most effective, because it resulted in smaller daily inside dry-bulb temperature variation, maximum reduction of apparent heat stress intensity, and lower total consumption of water.
Показать больше [+] Меньше [-]Ключевые слова АГРОВОК
Библиографическая информация
Эту запись предоставил National Agricultural Library