Loop-Mediated Isothermal Amplification as a Simple Molecular Method for the Detection of Derzsy’s Disease Virus
2013
Tarasiuk Karolina | Woźniakowski Grzegorz | Samorek-Salamonowicz Elżbieta
The objective of the study was to develop a simple and rapid molecular method for the detection of GPV. Twenty seven goose parvovirus (GPV) isolates collected from geese flocks in Poland were examined. Three pairs of specific primers: two outer primers (F3 and B3), two inner primers (FIP and BIP), and two loop primers (FL and BL) were used to accelerate the reaction. The optimum temperature and time of the reaction were 60°C and 30 min. The sensitivity of the method was 10-times higher than PCR. The method proved to be a sensitive, rapid, and specific assay for detecting GPV.
Показать больше [+] Меньше [-]Ключевые слова АГРОВОК
Библиографическая информация
Эту запись предоставил Directory of Open Access Journals