Уточнить поиск
Результаты 441-450 из 706
Patterns of antibiotic resistance in Escherichia coli isolated from fresh and recycled poultry litter
2017
Sung, H.W., Kangwon National University, Chuncheon, Republic of Korea | Choi, K.S., Animal and Plant Quarantine Agency, Gimcheon, Republic of Korea | Kwon, H.M., Kangwon National University, Chuncheon, Republic of Korea | Lee, Y.J., Kyungpook National University, Daegu, Republic of Korea
The isolation rate of Escherichia (E.) coli in poultry litter was investigated at 44 broiler farms, 20 that used fresh litter and 24 that used recycled litter. The patterns of resistance to antibiotics of the E. coli isolates were compared. In litter sampled before the rearing period, the isolation rate of E. coli was higher at farms that used fresh litter; E. coli was present in the litter in 94.5% (35 out of 37 flocks tested) of the farms that used fresh litter vs. 51.2% (21 out of 41 flocks) of the farms that used recycled litter. The susceptibility of the 93 isolates of E. coli to 13 antibiotics was studied. Before the rearing period, E. coli isolates from the farms that recycled litter showed higher resistance rates than isolates from farms that replaced litter with fresh litter. Comparing the antibiotic resistance patterns of isolates from litter sampled before and at the end of the rearing period, the antibiotic resistance rates at the end of the rearing period increased dramatically compared with rates before the rearing period.
Показать больше [+] Меньше [-]A simultaneous occurrence of feline mammary carcinoma and uterine cystic endometrial hyperplasia in a cat
2017
Yoo, J.H., National Institute of Animal Science, Rural Development Administration, Wanju, Republic of Korea | Kim, O., Wonkwang University, Iksan, Republic of Korea
At the time of visiting, the cat was 6-year-old female Siamese cat. The mammary mass was solid and firm and measured 2 x 5 cm2 in greatest diameter. The uterus revealed thick uterine horn and cross sectioned wall. Histopathologically, the mammary mass revealed feline mammary carcinoma. In the uterus, cystic endometrial hyperplasia was observed. Feline leukemia virus positive reaction was detected by polymerase chain reaction. As far as we know, this is the first report of the simultaneous feline mammary carcinoma and uterine endometrial cystic hyperplasia with Feline leukemia virus infection in a cat.
Показать больше [+] Меньше [-]Magnetic resonance imaging measurements of organs within the coelomic cavity of red-eared sliders (Trachemys scripta elegans), yellow-bellied sliders (Trachemys scripta scripta), Coastal plain cooters (Pseudemys concinna floridana), and hieroglyphic river cooters (Pseudemys concinna hieroglyphica)
2017
Mathes, Karina A. | Schnack, Marcus | Rohn, Karl | Fehr, Michael
OBJECTIVE To determine anatomic reference points for 4 turtle species and to evaluate data on relative anatomic dimensions, signal intensities (SIs), and position of selected organs within the coelomic cavity by use of MRI. ANIMALS 3 turtle cadavers (1 red-eared slider [Trachemys scripta elegans], 1 yellow-bellied slider [Trachemys scripta scripta], and 1 Coastal plain cooter [Pseudemys concinna floridana]) and 63 live adult turtles (30 red-eared sliders, 20 yellow-bellied sliders, 5 Coastal plain cooters, and 8 hieroglyphic river cooters [Pseudemys concinna hieroglyphica]). PROCEDURES MRI and necropsy were performed on the 3 turtle cadavers. Physical examination, hematologic evaluation, and whole-body radiography were performed on the 63 live turtles. Turtles were sedated, and MRI in transverse, sagittal, and dorsal planes was used to measure organ dimensions, position within the coelomic cavity, and SIs. Body positioning after sedation was standardized with the head, neck, limbs, and tail positioned in maximum extension. RESULTS Measurements of the heart, liver, gallbladder, and kidneys in sagittal, transverse, and dorsal planes; relative position of those organs within the coelom; and SIs of the kidneys and liver were obtained with MRI and provided anatomic data for these 4 turtle species. CONCLUSIONS AND CLINICAL RELEVANCE MRI was a valuable tool for determining the position, dimensions, and SIs of selected organs. Measurement of organs in freshwater chelonians was achievable with MRI. Further studies are needed to establish reference values for anatomic structures in turtles. Results reported here may serve as guidelines and aid in clinical interpretation of MRI images for these 4 species.
Показать больше [+] Меньше [-]In vitro effect of blood cell counts on multiple-electrode impedance aggregometry in dogs
2017
Nash, Katherine J. | Bacek, Lenore M. | Christopherson, Pete W. | Spangler, Elizabeth A.
OBJECTIVE To assess the effect of decreased platelet and WBC counts on platelet aggregation as measured by a multiple-electrode impedance aggregometer in dogs. ANIMALS 24 healthy dogs. PROCEDURES From each dog, 9 mL of blood was collected into a 10-mL syringe that contained 1 mL of 4% sodium citrate solution to yield a 10-mL sample with a 1:9 citrate-to-blood ratio. Each sample was then divided into unmanipulated and manipulated aliquots with progressively depleted buffy-coat fractions such that 2 to 3 blood samples were evaluated per dog. The Hct for manipulated aliquots was adjusted with autologous plasma so that it was within 2% of the Hct for the unmanipulated aliquot for each dog. All samples were analyzed in duplicate with a multiple-electrode impedance aggregometer following the addition of ADP as a platelet agonist. The respective effects of platelet count, plateletcrit, Hct, and WBC count on platelet aggregation area under the curve (AUC), aggregation, and velocity were analyzed with linear mixed models. RESULTS WBC count was positively associated with platelet AUC, aggregation, and velocity; blood samples with leukopenia had a lower AUC, aggregation, and velocity than samples with WBC counts within the reference range. Platelet count, plateletcrit, and Hct did not have an independent effect on AUC, aggregation, or velocity. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that WBC count was positively associated with platelet aggregation when ADP was used to activate canine blood samples for impedance aggregometry. That finding may be clinically relevant and needs to be confirmed by in vivo studies.
Показать больше [+] Меньше [-]Pharmacokinetics of ampicillin-sulbactam in serum and synovial fluid samples following regional intravenous perfusion in the distal portion of a hind limb of adult cattle
2017
Depenbrock, Sarah M. | Simpson, Katharine M. | Niehaus, Andrew J. | Lakritz, Jeffrey | Papich, Mark G.
OBJECTIVE To describe concentration-over-time data for ampicillin and sulbactam in the digital and systemic circulations and synovial fluid (SYN) of cattle following a single injection of ampicillin-sulbactam as a regional IV perfusion (RIVP). ANIMALS 6 healthy adult nonlactating Jersey-crossbred cows. PROCEDURES The right hind limb of each cow was aseptically prepared. A tourniquet was applied around the midmetatarsal region, and 1.0 g of ampicillin with 0.5 g of sulbactam in a combined formulation was administered as an RIVP into the dorsal common digital vein (DCDV). Blood samples from the DCDV and jugular vein and SYN samples from the metatarsophalangeal joint of the prepared limb were collected immediately before and at predetermined times for 24 hours after RIVP. One blood sample was obtained from the abaxial proper plantar vein of the lateral digit of the prepared limb 0.25 hours after RIVP. Serum and SYN ampicillin and sulbactam concentrations were determined by high-performance liquid chromatography. RESULTS Mean ± SD maximum concentration of ampicillin in SYN and serum obtained from the abaxial proper plantar and jugular veins was 1,995 ± 1,011 μg/mL, 5,422 ± 1,953 μg/mL, and 2.5 ± 1.6 μg/mL, respectively. Corresponding serum and SYN concentrations of sulbactam were lower but followed the same pattern over time as those for ampicillin. Synovial fluid ampicillin concentration remained above 8 μg/mL for a mean time of 18.9 hours. CONCLUSIONS AND CLINICAL RELEVANCE Potentially therapeutic concentrations of ampicillin were achieved in regional serum and SYN samples; SYN concentrations remained at potentially therapeutic values for > 12 hours following RIVP of 1.5 g of ampicillin-sulbactam in the hind limb of healthy cows.
Показать больше [+] Меньше [-]Assessment of the immunogenicity of rabies vaccine preserved by vaporization and delivered to the duodenal mucosa of gray foxes (Urocyon cinereoargenteus)
2017
Smith, Todd G. | Wu, Xianfu | Ellison, James A. | Wadhwa, Ashutosh | Franka, Richard | Langham, Gregory L. | Skinner, Brianna L. | Hanlon, Cathleen A. | Bronshtein, Victor L.
OBJECTIVE To assess the immunogenicity of thermostable live-attenuated rabies virus (RABV) preserved by vaporization (PBV) and delivered to the duodenal mucosa of a wildlife species targeted for an oral vaccination program. ANIMALS 8 gray foxes (Urocyon cinereoargenteus). PROCEDURES Endoscopy was used to place RABV PBV (n = 3 foxes), alginate-encapsulated RABV PBV (3 foxes), or nonpreserved RABV (2 foxes) vaccine into the duodenum of foxes. Blood samples were collected weekly to monitor the immune response. Saliva samples were collected weekly and tested for virus shedding by use of a conventional reverse-transcriptase PCR assay. Foxes were euthanized 28 days after vaccine administration, and relevant tissues were collected and tested for presence of RABV. RESULTS 2 of 3 foxes that received RABV PBV and 1 of 2 foxes that received nonpreserved RABV seroconverted by day 28. None of the 3 foxes receiving alginate-encapsulated RABV PBV seroconverted. No RABV RNA was detected in saliva at any of the time points, and RABV antigen or RNA was not detected in any of the tissues obtained on day 28. None of the foxes displayed any clinical signs of rabies. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study indicated that a live-attenuated RABV vaccine delivered to the duodenal mucosa can induce an immune response in gray foxes. A safe, potent, thermostable RABV vaccine that could be delivered orally to wildlife or domestic animals would enhance current rabies control and prevention efforts.
Показать больше [+] Меньше [-]Quality assessment of fluconazole capsules and oral suspensions compounded by pharmacies located in the United States
2017
Laporte, Carnie M. | Cruz-Espindola, Crisanta | Thungrat, Kamoltip | Schick, Anthea E. | Lewis, Thomas P II | Boothe, Dawn M.
OBJECTIVE To evaluate pharmaceutical characteristics (strength or concentration, accuracy, and precision), physical properties, and bacterial contamination of fluconazole compounded products. SAMPLE Fluconazole compounded products (30- and 240-mg capsules; 30- and 100-mg/mL oral suspensions) from 4 US veterinary compounding pharmacies. PROCEDURES Fluconazole compounded products were ordered 3 times from each of 4 pharmacies at 7- or 10-day intervals. Generic fluconazole products (50- and 200-mg tablets; 10- and 40-mg/mL oral suspensions) served as references. Compounded products were evaluated at the time of receipt; suspensions also were evaluated 3 months later and at beyond-use dates. Evaluations included assessments of strength (concentration), accuracy, precision, physical properties, and bacterial contamination. Acceptable accuracy was defined as within ± 10% of the labeled strength (concentration) and acceptable precision as within ± 10%. Fluconazole was quantified by use of high-performance liquid chromatography. RESULTS Physical characteristics of compounded products differed among pharmacies. Aerobic bacterial cultures yielded negative results. Capsules (30 and 240 mg) had acceptable accuracy (median, 96.3%; range, 87.3% to 135.2%) and precision (mean ± SD, 7.4 ± 6.0%). Suspensions (30 and 100 mg/mL) had poor accuracy (median, 73.8%; range, 53.9% to 95.2%) and precision (mean ± SD, 15.0 ± 6.9%). Accuracy and precision were significantly better for capsules than for suspensions. CONCLUSIONS AND CLINICAL RELEVANCE Fluconazole compounded products, particularly suspensions, differed in pharmaceutical and physical qualities. Studies to evaluate the impact of inconsistent quality on bioavailability or clinical efficacy of compounded fluconazole products are indicated, and each study should include data on the quality of the compounded product evaluated.
Показать больше [+] Меньше [-]Magnetic resonance imaging susceptibility artifacts in the cervical vertebrae and spinal cord related to monocortical screw–polymethylmethacrylate implants in canine cadavers
2017
Jones, B. G. | Fosgate, Geoffrey T. | Green, Eric M. | Habing, Amy M. | Hettlich, Bianca F.
OBJECTIVE To characterize and compare MRI susceptibility artifacts related to titanium and stainless steel monocortical screws in the cervical vertebrae and spinal cord of canine cadavers. SAMPLE 12 canine cadavers. PROCEDURES Cervical vertebrae (C4 and C5) were surgically stabilized with titanium or stainless steel monocortical screws and polymethylmethacrylate. Routine T1-weighted, T2-weighted, and short tau inversion recovery sequences were performed at 3.0 T. Magnetic susceptibility artifacts in 20 regions of interest (ROIs) across 4 contiguous vertebrae (C3 through C6) were scored by use of an established scoring system. RESULTS Artifact scores for stainless steel screws were significantly greater than scores for titanium screws at 18 of 20 ROIs. Artifact scores for titanium screws were significantly higher for spinal cord ROIs within the implanted vertebrae. Artifact scores for stainless steel screws at C3 were significantly less than at the other 3 cervical vertebrae. CONCLUSIONS AND CLINICAL RELEVANCE Evaluation of routine MRI sequences obtained at 3.0 T revealed that susceptibility artifacts related to titanium monocortical screws were considered mild and should not hinder the overall clinical assessment of the cervical vertebrae and spinal cord. However, mild focal artifacts may obscure small portions of the spinal cord or intervertebral discs immediately adjacent to titanium screws. Severe artifacts related to stainless steel screws were more likely to result in routine MRI sequences being nondiagnostic; however, artifacts may be mitigated by implant positioning.
Показать больше [+] Меньше [-]Body weight, blood pressure, and systemic changes following low-dosage prednisolone administration in dogs
2017
Yi, Sang-gwŏn | Park, Seungjo | Cheon, Byunggyu | Kim, Hyun Woo | Yu, Dohyeon | Choi, Jihye
OBJECTIVE To investigate systemic changes following low-dosage prednisolone administration in dogs. ANIMALS 4 healthy purpose-bred adult male Beagles. PROCEDURES Dogs were administered prednisolone PO at a dosage of 2 mg/kg/d for 2 weeks, 1 mg/kg/d for 4 weeks, and 0.5 mg/kg/d for 3 weeks. Body weight, blood pressure, hepatic size and echogenicity, percentage of vacuolated hepatocytes, serum hepatic enzyme activities and glucose concentration, adrenal gland size, and pancreatic echogenicity were evaluated weekly for 9 weeks. RESULTS The only significant change identified was an increase in hepatic echogenicity, assessed by measuring liver-kidney contrast on ultrasonographic images. Increases in hepatic size and percentage of vacuolated hepatocytes were identified, but values did not differ from baseline values. Similarly, serum hepatic enzyme activities increased, but changes were mild and not significantly different from baseline values. Body weight, pancreatic echogenicity, and serum glucose concentration did not show noticeable changes. Mild systemic hypertension was seen, but blood pressure was not significantly different from the baseline value. Similarly, adrenal gland size steadily decreased during the first 6 weeks and increased again after the prednisolone dosage was decreased to 0.5 mg/kg/d. However, mean adrenal gland size was not significantly different from the baseline value at any time. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that in dogs, administration of prednisolone at a low dosage was associated with minimal systemic effects.
Показать больше [+] Меньше [-]Variance associated with walking velocity during force platform gait analysis of a heterogeneous sample of clinically normal dogs
2017
Piazza, Alexander M. | Binversie, Emily E. | Baker, Lauren A. | Nemke, Brett | Sample, Susannah J. | Muir, Peter
OBJECTIVE To determine whether walking at specific ranges of absolute and relative (V*) velocity would aid efficient capture of gait trial data with low ground reaction force (GRF) variance in a heterogeneous sample of dogs. ANIMALS 17 clinically normal dogs of various breeds, ages, and sexes. PROCEDURES Each dog was walked across a force platform at its preferred velocity, with controlled acceleration within 0.5 m/s2. Ranges in V* were created for height at the highest point of the shoulders (withers; WHV*). Variance effects from 8 walking absolute velocity ranges and associated WHV* ranges were examined by means of repeated-measures ANCOVA. RESULTS The individual dog effect provided the greatest contribution to variance. Narrow velocity ranges typically resulted in capture of a smaller percentage of valid trials and were not consistently associated with lower variance. The WHV* range of 0.33 to 0.46 allowed capture of valid trials efficiently, with no significant effects on peak vertical force and vertical impulse. CONCLUSIONS AND CLINICAL RELEVANCE Dogs with severe lameness may be unable to trot or may have a decline in mobility with gait trial repetition. Gait analysis involving evaluation of individual dogs at their preferred absolute velocity, such that dogs are evaluated at a similar V*, may facilitate efficient capture of valid trials without significant effects on GRF. Use of individual velocity ranges derived from a WHV* range of 0.33 to 0.46 can account for heterogeneity and appears suitable for use in clinical trials involving dogs at a walking gait.
Показать больше [+] Меньше [-]