Уточнить поиск
Результаты 631-640 из 789
Effects of administration of adipose-derived stromal vascular fraction and platelet-rich plasma to dogs with osteoarthritis of the hip joints Полный текст
2016
Upchurch, David A. | Renberg, Walter C. | Roush, James K. | Milliken, George A. | Weiss, Mark L.
OBJECTIVE To evaluate effects of simultaneous intra-articular and IV injection of autologous adipose-derived stromal vascular fraction (SVF) and platelet-rich plasma (PRP) to dogs with osteoarthritis of the hip joints. ANIMALS 22 client-owned dogs (12 placebo-treated [control] dogs and 10 treated dogs). PROCEDURES Dogs with osteoarthritis of the hip joints that caused signs of lameness or discomfort were characterized on the basis of results of orthopedic examination, goniometry, lameness score, the Canine Brief Pain Inventory (CBPI), a visual analogue scale, and results obtained by use of a pressure-sensing walkway at week 0 (baseline). Dogs received a simultaneous intraarticular and IV injection of SVF and PRP or a placebo. Dogs were examined again 4, 8, 12, and 24 weeks after injection. RESULTS CBPI scores were significantly lower for the treatment group at week 24, compared with scores for the control group. Mean visual analogue scale score for the treatment group was significantly higher at week 0 than at weeks 4, 8, or 24. Dogs with baseline peak vertical force (PVF) in the lowest 25th percentile were compared, and the treatment group had a significantly higher PVF than did the control group. After the SVF-PRP injection, fewer dogs in the treated group than in the control group had lameness confirmed during examination. CONCLUSIONS AND CLINICAL RELEVANCE For dogs with osteoarthritis of the hip joints treated with SVF and PRP, improvements in CBPI and PVF were evident at some time points, compared with results for the control group.
Показать больше [+] Меньше [-]Effects of catheter shape, interelectrode spacing, and electrode size on transesophageal atrial pacing in dogs Полный текст
2016
Sanders, Robert A. | Chapel, Emily H.
OBJECTIVE To determine effects of catheter shape, interelectrode spacing (IS), and electrode size (ES) on pacing threshold (PT), extraneous muscular stimulation (EMS), and zone of capture (ZOC) for dogs undergoing transesophageal atrial pacing (TAP). ANIMALS 10 purpose-bred dogs without cardiac conduction disturbances. PROCEDURES 7 configurations for TAP catheters were tested in each dog to evaluate effects of catheter shape (curved or straight), IS (5, 15, and 25 mm), and ES (2, 4, and 6 mm). Each catheter was passed into the esophagus to a location aboral to the heart and slowly withdrawn until atrial pacing was achieved. Then, catheters were withdrawn in 5-mm increments until pacing could not be achieved. Outcomes measured at each pacing site included PT, degree of EMS, and ZOC. RESULTS There was a significantly lower PT, wider ZOC, and less EMS for the curved catheter than for the straight catheter. An ES of 6 mm induced significantly more EMS than was induced by an ES of 2 or 4 mm. An IS of 5 mm induced significantly less EMS and a significantly narrower ZOC but required a significantly higher PT, compared with results for an ES of 15 or 25 mm. Additionally, there was a significant direct correlation between IS and ZOC. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that a curved catheter with multiple 4-mm electrodes that provides for variable IS would be ideal for TAP in dogs. IMPACT FOR HUMAN MEDICINE TAP catheters currently used in human medicine are straight. The PT in humans may potentially be reduced with curved catheters.
Показать больше [+] Меньше [-]In vitro development and evaluation of a polyacrylic acid–silicone device intended for gradual occlusion of portosystemic shunts in dogs and cats Полный текст
2016
Wallace, Mandy L. | Ellison, Gary W. | Batich, Christopher | Case, Brad | Kim, Stanley E.
OBJECTIVE To develop a device intended for gradual venous occlusion over 4 to 6 weeks. SAMPLE Silicone tubing filled with various inorganic salt and polyacrylic acid (PAA) formulations and mounted within a polypropylene or polyether ether ketone (PEEK) outer ring. PROCEDURES 15 polypropylene prototype rings were initially filled with 1 of 5 formulations and placed in PBSS. In a second test, 10 polypropylene and 7 PEEK prototype rings were filled with 1 formulation and placed in PBSS. In a third test, 2 formulations were loaded into 6 PEEK rings each, placed in physiologic solution, and incubated. In all tests, ring luminal diameter, outer diameter, and luminal area were measured over 6 weeks. RESULTS In the first test, 2 formulations had the greatest changes in luminal area and diameter, and 1 of those had a greater linear swell rate than the other had. In the second test, 6 of 7 PEEK rings and 6 of 10 polypropylene rings closed to a luminal diamater < 1 mm within 6 weeks. Polypropylene rings had a greater increase in outer diameter than did PEEK rings between 4.5 and 6 weeks. In the third test, 11 of 12 PEEK rings gradually closed to a luminal diameter < 1 mm within 6 weeks. CONCLUSIONS AND CLINICAL RELEVANCE A PAA and inorganic salt formulation in a prototype silicone and polymer ring resulted in gradual occlusion over 4 to 6 weeks in vitro. Prototype PEEK rings provided more reliable closure than did polypropylene rings.
Показать больше [+] Меньше [-]Effects of repeated gas sterilization on closure rates of ameroid ring constrictors in vitro Полный текст
2016
Kimberlin, William W. | Wardlaw, Jennifer L. | Madsen, Richard W.
OBJECTIVE To determine the effect of repeated gas sterilization on rate of closure of ameroid ring constrictors in vitro. SAMPLE Twenty-four 3.5-mm ameroid ring constrictors. PROCEDURES Ameroid ring constrictors were allocated to 1 of 4 treatment groups (6/group) to undergo gas sterilization 0, 1, 5, or 10 times. After sterilization, constrictors were incubated in canine plasma at a protein concentration of 3 g/dL for 27 days. A digital camera was used to obtain images of the constrictors prior to and at various points during incubation, and lumen diameter was measured. RESULTS Mean ± SD percentage of lumen closure for all groups of ameroid ring constrictors combined was 85.2 ± 1.6% at day 0 (prior to plasma incubation) and 95.4 ± 0.8% at day 27. Mean lumen area was 3.64 ± 0.43 mm2 (95% confidence interval, 2.67 to 4.77 mm2) at day 0 and 1.32 ± 0.25 mm2 (95% confidence interval, 0.76 to 2.04 mm2) at day 27. None of the ameroid ring constrictors had closed completely by day 27. CONCLUSIONS AND CLINICAL RELEVANCE Overall closure rates for ameroid ring constrictors appeared to be unaffected by repeated gas sterilization up to 10 times. Findings suggested that veterinary surgeons can resterilize ameroid ring constrictors up to 10 times with confidence that ring properties would remain suitable for clinical use.
Показать больше [+] Меньше [-]Comparison of blood pressure measurements of anesthetized dogs obtained noninvasively with a cylindrical blood pressure cuff and an anatomically modified conical blood pressure cuff Полный текст
2016
Ramos, Sara J. | Da Cunha, Anderson F. | Domingues, Michelle | Shelby, Amanda M. | Stout, Rhett W. | Acierno, Mark J.
OBJECTIVE To compare blood pressure measured noninvasively with an oscillometric device that involved use of a novel conical cuff and a traditional cylindrical blood pressure cuff. ANIMALS 17 adult hound-type dogs. PROCEDURES Dogs were anesthetized, and a 20-gauge, 1.5-inch catheter was inserted in the median sacral artery. The catheter was attached to a pressure transducer via fluid-filled noncompliant tubing, and direct blood pressure was recorded with a multifunction monitor. A specially fabricated conical cuff was placed on the antebrachium. Four sets of direct and indirect blood pressure measurements were simultaneously collected every 2 minutes. Four sets of measurements were then obtained by use of a cylindrical cuff. RESULTS The cylindrical cuff met American College of Veterinary Internal Medicine consensus guidelines for validation of indirect blood pressure measurements for mean arterial blood pressure (MAP), systolic arterial blood pressure (SAP), and diastolic arterial blood pressure (DAP). The conical cuff met the consensus guidelines for difference of paired measurements, SD, and percentages of measurements within 10 and 20 mm Hg of the value for the reference method, but it failed a correlation analysis. In addition, although bias for the conical cuff was less than that for the cylindrical cuff for SAP, MAP, and DAP measurements, the limits of agreement for the conical cuff were wider than those for the cylindrical cuff for SAP and MAP measurements. CONCLUSIONS AND CLINICAL RELEVANCE On the basis of results of this study, use of a conical cuff for oscillometric blood pressure measurement cannot be recommended.
Показать больше [+] Меньше [-]Effects on indicators of tissue perfusion in dogs anesthetized with isoflurane at two multiples of the minimum alveolar concentration Полный текст
2016
Floriano, Beatriz P. | Wagatsuma, Juliana T. | Ferreira, Joana Z. | Abimussi, Caio J. X. | Menegheti, Thais M. | Santos, Paulo S. P. | Oliva, Valeria N. L. S.
OBJECTIVE To investigate the effects of isoflurane anesthesia administered at 2 multiples of the minimum alveolar concentration (MAC) on tissue perfusion in dogs. ANIMALS 8 healthy young adult Beagles. PROCEDURES A randomized crossover design was used. Dogs were anesthetized with isoflurane at 1.5 or 2.0 times the MAC for 2 hours, a 7-day washout period was provided, and dogs were reanesthetized with the alternate treatment. Various physiologic variables were monitored before anesthesia (baseline), at 20-minute intervals during anesthesia, and after anesthetic recovery. Variable values were compared between MAC multiples by means of repeated-measures ANOVA, with the Tukey test used for multiple comparisons. RESULTS During anesthesia, mean arterial blood pressure, cardiac output, and mixed venous oxygen saturation were significantly greater when isoflurane was administered at 1.5 versus 2.0 times the MAC. Cardiac output gradually increased during anesthesia at 1.5 times but not at 2.0 times the MAC. Arterial blood lactate concentration did not differ between MAC multiples at any point; however, this concentration decreased with increasing anesthetic duration at both MAC multiples. Oxygen delivery differed between MAC multiples, and oxygen consumption differed from baseline during anesthesia at 2.0 times the MAC. Oxygen extraction was higher at 2.0 versus 1.5 times the MAC. Heart rate differed between MAC multiples only after anesthetic recovery. CONCLUSIONS AND CLINICAL RELEVANCE Isoflurane anesthesia impaired tissue perfusion in dogs, but these changes would not be clinically relevant with oxygen delivery at 100%. Peripheral tissue perfusion was maintained or improved with time.
Показать больше [+] Меньше [-]Lambda cyhalothrin toxicity induces alterations in lipogenic genes and inflammatory factors in rat liver Полный текст
2016
Moustafa, G.G. (Zagazig University (Egypt). Faculty of Veterinary Medicine, Department of Forensic medicine and Toxicology) | Hussein, M.M.A.
Single nucleotide polymorphisms of Kit gene in Chinese indigenous horses Полный текст
2016
Han, H. (Northwest A and F University, Shaanxi (China). College of Animal Science and Technology) | Mao, C. | Chen, N. | Lan, X. | Chen, H. | Lei, C. | Dang, R.
Surgical stabilization of the atlanto-occipital overlap with atlanto-axial instability in a dog Полный текст
2016
Fujita, A. (the University of Tokyo, Bunkyo-ku, Tokyo (Japan). Veterinary Medical Center) | Nishimura, R.
Evaluation of weekly bathing in allergic dogs with methicillin-resistant Staphylococcal colonization Полный текст
2016
Kawarai, S. (Azabu University, Sagamihara, Kanagawa (Japan). Veterinary Teaching Hospital Laboratory of Small Animal Clinics; Department of Veterinary Medicine) | Fujimoto, A. | Nozawa, G. | Kanemaki, N. | Madarame, H. | Shida, T. | Kiuchi, A.