Optimization of sewerage system in Riga city
2006
Juhna, V. | Tilgalis, E. | Ziemelnieks, R.
In the paper there are described problems of sewerage system in Riga which essentially impede its normal functioning. There are analyzed operation regimes of two principal pumping stations which pump all wastewater of Riga to the purification plants (2001-2005). The main focus is on implementing different measures that would improve collection and pumping of wastewater. It is offered to build a third penstock from the Voleru chamber to the purification plants. It is suggested to separate the rainwater from the household wastewater. There are analyzed 11 different versions of pump operation. In the conclusions and recommendations the formation of the possible dangerous situation during heavy downpours is demonstrated. It is recommended to build a regulation reservoir near the purification plants which could essentially protect the Daugava from unpurified wastewater during the downpours.