Accuracy of transvaginal ultrasonography for early pregnancy diagnosis in Attappady black goats
2017
Philip, Laiju M. | Abhilash, R. S. | Francis, Bastin P.
Transabdominal ultrasonography has been popularly used in animal reproduction for the assessment of pregnancy status and foetal viability where as transvaginal method for pregnancy diagnosis is rarely used for pregnancy diagnosis in goats. The study was conducted in 74 Attappady Black goats from Government Goat Farm, Attappady and Livestock Research Station, Thiruvizhamkunnu to evaluate the accuracy of trans-vaginal methods and to identify the fetal characteristics from day 20 to 75. Transvaginal ultrasonographic examination was performed using endocavity transducer with frequency of 6.5 to 8 MHz. Observations were made in all the pregnant does at three different stages of pregnancy i.e., 20-35 days, 35-55 days and 55-75 days. Does were diagnosed as pregnant from the observation of gestational sac, embryo or foetus, embryonic or foetal heartbeat, placentomes or foetal skeleton. Sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy along gestation period were 98.03, 92.3, 96.15, 96 and 95.62%, respectively. It is concluded from the present study that transvaginal ultrasonography can be used for herd pregnancy diagnosis at early stages from day 20 to 45 of pregnancy diagnosis in goats.