Respiration Rate Measurement of Grapes Under Closed System
2015
Bangale, Sagar Ramesh | Ramanathan, M. | Thirupathi, V.
A closed system was developed to measure O₂and CO‚ resulting from respiration of grapes (vitis vinifera). respiration rate was measured in terms of production of CO₂ and uptakeof O₂ contents were measured by using gas meter Checkmate II, PBI. Oxygen and carbon dioxide levels were measured over time and the respiratory quotient (RQ) of grapes was estimated as 1.90mg kg⁻¹h⁻¹ and 1.60 mg kg⁻¹h⁻¹ for black grapes and white grapes respectively. The study was carried out at different temperature 5, 10, 15, and 28 ÚC and quality analysis of grapes viz. Total soluble solid, acidity, pH, anthocyanin content for 96 h was carried out in a static system
显示更多 [+] 显示较少 [-]