Simultaneous Pollutant Removal and Electricity Generation in a Combined ABR-MFC-MEC System Treating Fecal Wastewater
2017
Liu, Hongbo | Leng, Feng | Guan, Yonglian | Yao, Yangyang | Li, Yanhua | Xu, Suyun
Simultaneous power generation and fecal wastewater treatment were investigated using a combined ABR-MFC-MEC system (anaerobic baffled reactor-microbial fuel cell-microbial electrolysis cell). The installation of multi-stage baffles can benefit retaining the suspended solids in the system and help separate the hydrolysis-acidification and the methanogen processes. The efficiencies of the nitrification-denitrification process were improved because of the weak current generation by coupling the microbial electrochemical device (MFC-MEC) with the ABR unit. Maximum removal rates for chemical oxygen demand (COD) and ammonia nitrogen (NH₄ ⁺-N) were 1.35 ± 0.05 kg COD/m³/day and 85.0 ± 0.4 g NH₄ ⁺-N/m³/day, respectively, while 45% of methane (CH₄), 9% of carbon dioxide (CO₂), and 45% of nitrogen gas (N₂) contents in volume ratio were found in the collected gas phase. An average surplus output voltage of 452.5 ± 10.5 mV could be achieved from the combined system, when the initial COD concentration was 1500.0 ± 20.0 mg/L and the initial NH₄ ⁺-N concentration was 110.0 ± 5.0 mg/L, while the effluent COD could reach 50.0 mg/L with an HRT of 48 h. The combined process has the potential to treat fecal wastewater efficiently with nearly zero energy input and a fair bio-fuel production.