Sample port design for ballast water sampling: Refinement of guidance regarding the isokinetic diameter
2015
Wier, Timothy P. | Moser, Cameron S. | Grant, Jonathan F. | First, Matthew R. | Riley, Scott C. | Robbins-Wamsley, Stephanie H. | Drake, Lisa A.
By using an appropriate in-line sampling system, it is possible to obtain representative samples of ballast water from the main ballast line. An important parameter of the sampling port is its “isokinetic diameter” (DISO), which is the diameter calculated to determine the velocity of water in the sample port relative to the velocity of the water in the main ballast line. The guidance in the U.S. Environmental Technology Verification (ETV) program protocol suggests increasing the diameter from 1.0× DISO (in which velocity in the sample port is equivalent to velocity in the main line) to 1.5–2.0× DISO. In this manner, flow velocity is slowed—and mortality of organisms is theoretically minimized—as water enters the sample port. This report describes field and laboratory trials, as well as computational fluid dynamics modeling, to refine this guidance. From this work, a DISO of 1.0–2.0× (smaller diameter sample ports) is recommended.
显示更多 [+] 显示较少 [-]