Different alternative retrofit to improving the sustainability of building in tropical climate: multi-criteria decision-making
2022
Balasbaneh, Ali Tighnavard | Yeoh, David | Ramli, Mohd Zamri | Valdi, Mohammad Hossein Taghizadeh
With the growth of the number of old buildings in urban cities, there is an imperative demand for retrofitting those buildings to minimize their energy consumption and maximize their sustainability. This article seeks to provide a multi-criteria assessment of different retrofitting scenarios in the Malaysian context, focusing replacement of windows. Four different criteria assessed operation energy usage, global warming potential (GWP) emission, embodied energy, and the cost of each alternative. Life cycle analysis is used for each scenario using the Energy Plus software program to estimate the energy demand. The preliminary result showed that a louvered window is unsuitable for operational energy usage compared to other options. In embodied energy and GWP, double-glazing shows an optimal choice by 532 MJ kg/m² and 101 kg/M² CO₂ between the other two alternatives for retrofitting. However, in the operational energy category, triple glazing has the best performance by 1.06 kW/a day. Finally, comparing the cost of each other options, plenum windows have the lowest rate by 825 kg/M² MYR. Thus, multi-criteria decision-making (MCDM) is used to select the most sustainable window for buildings. The result shows that the best option is a double-glazing window, followed by a plenum window. This study revealed the requirement for utilization of MCDM handles to guarantee the correct choice of design strategies for the best decision.