Effect of Clamp Design on Fabric Breaking Strength
1948
Kelly, Warren T. | Hays, Margaret B.
The strength values of 10 fabrics, determined by the grab and raveled-strip methods and measured with the new Scott 2-inch fabric clamp and the standard 1-inch fabric clamp, were studied. It was found that the 2-inch fabric clamp did not give more accurate results although the number of jaw breaks was reduced 30 percent.