Mathematical model of heat transfer and enzyme inactivation in an integrated blancher cooler
2003
Arroqui, C. | Lopez, A. | Esnoz, A. | Virseda, P.
A simulation model of an integrated blancher/cooler machine has been developed. This is a water blancher system that maximizes the product quality and minimizes the water and energy consumption. With this model, specific energy consumption, enzyme inactivation and blanching capacity can be determined as a function of design variables, such as number of zones in the heating and cooling sections, water flow rate and the specific conditions of the thermal treatment to be applied to the product.
显示更多 [+] 显示较少 [-]AGROVOC关键词
书目信息
出版者
Taylor & Francis
其它主题
Integrated blancher/cooler machines; Energy use and consumption; Food processing (general); Mathematics and statistics