细化搜索
结果 1-9 的 9
Regional differences of densitometric and geometric parameters of the third metacarpal bone in coldblood horses – pQCT study
2017
Dzierzęcka, Małgorzata | Jaworski, Maciej | Purzyc, Halina | Barszcz, Karolina
Introduction: The aim of the study was to analyse selected densitometric and geometric parameters in the third metacarpal bone along the long axis in horses. The densitometric parameters included the cortical and trabecular bone mineral density, while the geometric parameters included the cortical, trabecular, and total areas, strength strain index X, strength strain index Y, and the polar strength strain index. Material and Methods: The parameters were analysed using eight sections from 10% to 80% of the length of the bone. Peripheral quantitative computed tomography was used in the study. Statistical analysis was carried out using the Friedman analysis of variance and post-hoc tests. Results: The proximal metaphyseal region showed the highest predicted resistance to bone fractures in the transverse (back-front) plane, the distal metaphyseal region had the highest predicted resistance to transverse and torsional fractures in the transverse (side-side) plane. The cross-sectional area and the shape of the cross-section of the cortical bone of the MCIII had the highest coefficient of variation. The density of the cortical bone was least variable. Conclusions: The cortical area and cortical bone mineral density assumed the highest values in the diaphyseal region, while the highest total area, trabecular area and trabecular bone mineral density values were obtained in the metaphyseal proximal and distal region.
显示更多 [+] 显示较少 [-]Hoof quality of Anglo-Arabian and Haflinger horses
2017
Tocci, Roberto | Sargentini, Clara | Martini, Andrea | Andrenelli, Luisa | Pezzati, Antonio | Benvenuti, Doria | Giorgetti, Alessandro
Introduction: Foot quality is essential to the horse’s movement. The barefoot approach favours the animal’s welfare. Environment and selection determine hoof characteristics. Material and Methods: Hoof characteristics of eight Anglo-Arabian (AA) and nine Haflinger (HA) horses were studied. After a preliminary visual analysis of feet, nail samples were collected after trimming for physico-chemical analysis. The parameters were submitted to analysis of variance. A principal component analysis and a Pearson correlation were used to compare mineral contents. Results: The hooves of both breeds were healthy and solid. The hooves of HA horses were longer than those of AA horses (14.90 ±0.30 cm vs 13.10 ±0.60 cm), while the AA hoof was harder than the HA hoof both in the wall (74.55 ±2.95 H vs 60.18 ±2.67 H) and sole (67.00 ±5.87 H vs 43.0 ±4.76 H). In comparison with the sole, the AA hoof wall also had a lower moisture percentage (12.56 ±0.67% vs 20.64 ±0.76%), while crude protein and ash contents were similar in both regions. The AA hoof showed a higher Se content, while the HA hoof had a higher level of macroelements. The negative correlations of K with Cu, Fe, Ni, Pb, and Zn in the AA hoof may indicate osmoregulation activity. Conclusion: The hoof morphology of AA and HA horses met the literature parameters for mesomorphic horses. Both breeds had healthy and well-conformed hooves, useful for sport and recreation activities.
显示更多 [+] 显示较少 [-]Comparison of insertion characteristics of tapered and cylindrical transfixation pins in third metacarpal bones of equine cadavers
2017
Adams, Mackenzie K. | Lescun, Timothy B. | Mechem, Alexis S. | Johnson, Whitney R. | Griffin, T Hall | Main, Russell P.
OBJECTIVE To compare heat generation and mechanical bone damage for tapered and cylindrical transfixation pins during drilling, tapping, and pin insertion in equine third metacarpal bones. SAMPLE 16 pairs of cadaveric equine third metacarpal bones. PROCEDURES For cylindrical pin insertion, a 6.2-mm hole was drilled and tapped with a cylindrical tap, and then a standard 6.3-mm pin was inserted. For tapered pin insertion, a 6.0-mm hole was drilled, reamed with a tapered reamer, and tapped with a tapered tap, and then a 6.3-mm tapered pin was inserted. Paired t tests and 1-way ANOVAs were used to compare heat generation (measured by use of thermocouples and thermography), macrodamage (assessed by use of stereomicroscopy), and microdamage (assessed by examination of basic fuchsin–stained histologic specimens) between cylindrical and tapered pins and between tapered pins inserted to various insertion torques. RESULTS Tapered pin insertion generated less heat but resulted in more bone damage than did cylindrical pin insertion when pins were inserted to the same insertion torque. Insertion of tapered pins to increasing insertion torques up to 16 N•m resulted in increased heat generation and bone damage. CONCLUSIONS AND CLINICAL RELEVANCE Tapered pin insertion resulted in lower heat production than did cylindrical pin insertion. However, tapered pin insertion resulted in greater bone damage, which likely was attributable to differences in the tapered and cylindrical taps. A tapered pin may be preferable to a cylindrical pin for insertion in equine cortical bone provided that improvements in tap design can reduce bone damage during insertion.
显示更多 [+] 显示较少 [-]In vivo evaluation of effects of sedation on results of acoustoelastography of the superficial digital flexor tendons in clinically normal horses
2017
De Gasperi, Diego | Dzierzak, Samantha L. | Muir, Peter | Vanderby, Ray Jr | Brounts, Sabrina H.
OBJECTIVE To assess the effects of sedation on results of acoustoelastography of the superficial digital flexor tendons (SDFTs) in clinically normal horses. ANIMALS 27 clinically normal horses. PROCEDURES For each horse, the pathology index (PI) for the SDFT of each thoracic limb was determined by use of acoustoelastography at 4 locations (5, 10, 15, and 20 cm distal to the accessory carpal bone). Horses were evaluated before and after they were sedated with a combination of detomidine hydrochloride (0.01 mg/kg, IV) and butorphanol tartrate (0.01 mg/kg, IV). A repeated-measures ANOVA was used for statistical analysis. RESULTS Overall, the PI was lower after sedation than before sedation. In addition, the PI was lower at more distal locations than at more proximal locations. There was not a significant effect of limb (left or right). Differences among individual horses accounted for the largest variance effect. CONCLUSIONS AND CLINICAL RELEVANCE Sedation with detomidine and butorphanol facilitated acoustoelastography; however, it decreased the SDFT PI in clinically normal horses and should be used consistently in prospective studies. Variance associated with each individual horse in the sample population had the greatest effect on the PI.
显示更多 [+] 显示较少 [-]Assessment of agreement among diplomates of the American College of Veterinary Anesthesia and Analgesia for scoring the recovery of horses from anesthesia by use of subjective grading scales and development of a system for evaluation of the recovery of horses from anesthesia by use of accelerometry
2017
Clark-Price, Stuart C. | Lascola, Kara M. | Carter, Jennifer E. | Da Cunha, Anderson F. | Donaldson, Lydia L. | Doherty, Thomas J. | Martin-Flores, Manuel | Hofmeister, Erik H. | Keating, Stephanie C. J. | Mama, Khursheed R. | Mason, Diane E. | Posner, Lysa P. | Sano, Hiroki | Seddighi, Reza | Shih, Andre C. | Weil, Ann B. | Schaeffer, David J.
OBJECTIVE To evaluate agreement among diplomates of the American College of Veterinary Anesthesia and Analgesia for scores determined by use of a simple descriptive scale (SDS) or a composite grading scale (CGS) for quality of recovery of horses from anesthesia and to investigate use of 3-axis accelerometry (3AA) for objective evaluation of recovery. ANIMALS 12 healthy adult horses. PROCEDURES Horses were fitted with a 3AA device and then were anesthetized. Eight diplomates evaluated recovery by use of an SDS, and 7 other diplomates evaluated recovery by use of a CGS. Agreement was tested with κ and AC1 statistics for the SDS and an ANOVA for the CGS. A library of mathematical models was used to map 3AA data against CGS scores. RESULTS Agreement among diplomates using the SDS was slight (κ = 0.19; AC1 = 0.22). The CGS scores differed significantly among diplomates. Best fit of 3AA data against CGS scores yielded the following equation: RS = 9.998 × SG(0.633) × ∑UG(0.174), where RS is a horse's recovery score determined with 3AA, SG is acceleration of the successful attempt to stand, and ∑UG is the sum of accelerations of unsuccessful attempts to stand. CONCLUSIONS AND CLINICAL RELEVANCE Subjective scoring of recovery of horses from anesthesia resulted in poor agreement among diplomates. Subjective scoring may lead to differences in conclusions about recovery quality; thus, there is a need for an objective scoring method. The 3AA system removed subjective bias in evaluations of recovery of horses and warrants further study.
显示更多 [+] 显示较少 [-]Dual-energy computed tomography of canine uroliths
2017
Nykamp, Stephanie G.
OBJECTIVE To determine whether dual-energy CT (DECT) could accurately differentiate the composition of common canine uroliths in a phantom model. SAMPLE 30 canine uroliths with pure compositions. PROCEDURES Each urolith was composed of ≥ 70% struvite (n = 10), urate (8), cystine (5), calcium oxalate (4), or brushite (3) as determined by standard laboratory methods performed at the Canadian Veterinary Urolith Centre. Uroliths were suspended in an agar phantom, and DECT was performed at low (80 kV) and high (140 kV) energies. The ability of low- and high-energy CT numbers, DECT number, and DECT ratio to distinguish uroliths on the basis of composition was assessed with multivariate ANOVA. RESULTS No single DECT measure differentiated all urolith types. The DECT ratio differentiated urate uroliths from all other types of uroliths. The DECT and low-energy CT numbers were able to differentiate between 8 and 7 pairs of urolith types, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that DECT was unable to differentiate common types of canine uroliths in an in vitro model; therefore, it is unlikely to be clinically useful for determining urolith composition in vivo. Given that the primary reasons for determining urolith composition in vivo are to predict response to shock wave lithotripsy and develop a treatment plan, future research should focus on the correlation between DECT measurements and urolith fragility rather than urolith composition.
显示更多 [+] 显示较少 [-]Pharmacokinetics of meloxicam after intramuscular and oral administration of a single dose to American flamingos (Phoenicopertus ruber)
2017
Boonstra, Jennifer L. | Cox, Sherry K. | Martin-Jimenez, Tomas
OBJECTIVE To determine pharmacokinetics after IM and oral administration of a single dose of meloxicam to American flamingos (Phoenicopertus ruber). ANIMALS 14 adult flamingos. PROCEDURES Flamingos were allocated to 2 groups. Each group received a dose of meloxicam (1 mg/kg) by the IM or oral route. After a 4-week washout period, groups received meloxicam via the other route of administration. Plasma meloxicam concentrations were measured with high-performance liquid chromatography. Data for each bird were analyzed. Estimated values of selected pharmacokinetic parameters were compared by use of a linear mixed-effects ANOVA. Pooled concentration-time profiles for each route of administration were analyzed to examine the influence of body weight on pharmacokinetics. RESULTS Mean ± SD maximum plasma concentration was 1.00 ± 0.88 μg/mL after oral administration. This was approximately 15% of the mean maximum plasma concentration of 5.50 ± 2.86 μg/mL after IM administration. Mean time to maximum plasma concentration was 1.33 ± 1.32 hours after oral administration and 0.28 ± 0.17 hours after IM administration. Mean half-life of the terminal phase after oral administration (3.83 ± 2.64 hours) was approximately twice that after IM administration (1.83 ± 1.22 hours). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that the extent and rate of meloxicam absorption were less after oral administration than after IM administration. Intramuscular administration resulted in a short period during which mean plasma concentrations met or exceeded reported efficacious analgesic concentrations in other species, whereas oral administration did not. These results suggested that higher doses may be required for oral administration.
显示更多 [+] 显示较少 [-]A technique of needle redirection at a single craniolateral site for injection of three compartments of the equine stifle joint
2017
Herdrich, Meredith R. A. | Arrieta, Shelby E. | Nelson, Brad B. | Frisbie, David D. | Moorman, Valerie J.
OBJECTIVE To determine accuracy for a technique of needle redirection at a single craniolateral site for injection of 3 compartments of the equine stifle joint, describe the external needle position, and identify the location of the needle tip within each joint compartment. SAMPLE 24 equine cadaver stifle joints. PROCEDURES Stifle joints were placed in a customized stand. After the needle was placed, external needle position was measured and recorded. Each joint compartment (medial and lateral compartments of the femorotibial joint and the femoropatellar joint) was injected with a solution containing iodinated contrast medium, water, and dye. Radiography, assessment of intra-articular location of the needle tip, and gross dissection were performed to determine success of entering each joint compartment. Student t tests and an ANOVA were used to compare mean values. RESULTS Overall accuracy was 19 of 24 (79.1%), and accuracy for individual joint compartments was at least 21 of 24 (87.5%). Mean depth of needle insertion to access each compartment of the stifle joint was 5.71 cm. Mean angle of insertion (relative to the long axis of the tibia) was 82.1°, 80.3°, and 18.5° for the medial compartment of the femorotibial joint, lateral compartment of the femorotibial joint, and femoropatellar joint, respectively, and 28° medial, 7.3° lateral, and 1.3° lateral for the medial compartment of the femorotibial joint, lateral compartment of the femorotibial joint, and femoropatellar joint, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results supported that this was an accurate technique for successful injection of the 3 equine stifle joint compartments.
显示更多 [+] 显示较少 [-]Evaluation of a portable media device for use in determining postural stability in standing horses
2017
Moorman, Valerie J. | Kawcak, Christopher E. | King, Melissa R.
OBJECTIVE To determine the ability of an accelerometer within a commercially available portable media device (PMD) to measure changes in postural stability of standing horses during various stance conditions and to compare these results with data obtained by use of a stationary force platform. ANIMALS 7 clinically normal horses. PROCEDURES A PMD was mounted on a surcingle; the surcingle was placed immediately caudal to the highest point of the shoulders (withers). Each horse was examined while standing on a stationary force platform system in a normal square stance, forelimb base-narrow stance, and normal square stance at 5 and 10 minutes after sedation induced by IV administration of xylazine hydrochloride. A minimum of 5 trials were conducted for each stance condition. Ranges of craniocaudal and mediolateral motion as well as SDs were collected for the PMD and force platform system. Analyses were performed with mixed-model ANOVAs, and correlation coefficients were calculated. RESULTS Stance condition significantly altered craniocaudal accelerations measured by use of the PMD, all craniocaudal and mediolateral displacements of the center of pressure, and velocities measured by use of the stationary force platform. For both the PMD and force platform, SDs were significantly affected by stance condition in both craniocaudal and mediolateral directions. Correlation coefficients between the systems for all variables were low to moderate (r = 0.18 to 0.58). CONCLUSIONS AND CLINICAL RELEVANCE Body-mounted PMDs should be investigated for use in assessment of postural stability in horses with neuromuscular abnormalities.
显示更多 [+] 显示较少 [-]