细化搜索
结果 1-4 的 4
Direct measurement of intracranial pressure in adult horses
2002
Brosnan, Robert J. | LeCouteur, Richard A. | Steffey, Eugene P. | Imai, Ayako | Kortz, Gregg D.
Objective-To develop a method for surgical placement of a commercial microsensor intracranial pressure (ICP) transducer and to characterize normal ICP and cerebral perfusion pressures (CPP) in conscious adult horses. Animals-6 healthy castrated male adult horses (1 Holsteiner, 1 Quarter Horse, and 4 Thoroughbreds). Procedure-Anesthesia was induced and maintained by use of isoflurane as the sole agent. Catheters were inserted percutaneously into the jugular vein and carotid artery. A microsensor ICP transducer was inserted in the subarachnoid space by means of right parietal craniotomy. The burr hole was then sealed with bone wax, the surgical incision was sutured, and the transducer was secured in place. Measurements were collected 1 hour after horses were able to stand during recovery from anesthesia. Results-Mean +/- SD values for ICP and CPP were 2 +/- 4 and 102 +/- 26 mm Hg, respectively. Conclusion and Clinical Relevance-This report describes a relatively facile technique for obtaining direct and accurate ICP measurements for adult horses. The ICP values obtained in this study are within reference ranges established for other species and provide a point of reference for the diagnosis of abnormal ICP in adult horses.
显示更多 [+] 显示较少 [-]Plasma concentrations of adrenocorticotrophic hormone and α-melanocyte-stimulating hormone in ferrets (Mustela putorius furo) with hyperadrenocorticism
2002
Schoemaker, Nico J. | Mol, Jan A. | Lumeij, J.T. | Rijnberk, Adam
Objective-To determine plasma concentrations of adrenocorticotrophic hormone (ACTH) and alpha-melanocyte stimulating-hormone (α-MSH) in healthyferrets and ferrets with hyperadrenocorticism. Animals-16 healthy, neutered, privately owned ferrets, 28 healthy laboratory ferrets (21 sexually intact and 7 neutered), and 28 ferrets with hyperadrenocorticism. Procedures-Healthy ferrets were used for determination of reference plasma concentrations of ACTH and alpha-MSH. Diagnosis of hyperadrenocorticism was made on the basis of history, clinical signs, urinary corticoid-to-creatinine ratios, ultrasonography of the adrenal glands, and macroscopic or microscopic evaluation of the adrenal glands. Blood samples were collected during isoflurane anesthesia. Plasma concentrations of ACTH and α-MSH were measured by radioimmunoassay. Results-Plasma concentrations of ACTH in 23 healthy neutered ferrets during the breeding season ranged from 4 to 145 ng/L (median, 50 ng/L). Plasma concentrations of α-MSH in 44 healthy neutered or sexually intact ferrets during the breeding season ranged from < 5 to 617 ng/L (median, 37 ng/L). Reference values (the central 95% of the values) for ACTH and α-MSH were 13 to 100 ng/L and 8 to 180 ng/L, respectively. Plasma concentrations of ACTH and α-MSH in ferrets with hyperadrenocorticism ranged from 1 to 265 ng/L (median, 45 ng/L) and 10 to 148 ng/L (median, 46 ng/L), respectively. These values were not significantly different from those of healthy ferrets. Plasma ACTH concentrations of sexually intact female ferrets in estrus were significantly higher than those of neutered females. Conclusions and Clinical Relevance-Ferrets with hyperadrenocorticism did not have detectable abnormalities in plasma concentrations of ACTH or α-MSH. The findings suggest that hyperadrenocorticism in ferrets is an ACTH and α-MSH-independent condition.
显示更多 [+] 显示较少 [-]Effect of intraluminal distention on microvascular perfusion in the equine small colon
2002
Faleiros, Rafael R. | Macoris, Delphim G. | Alessi, Antonio C. | Saquetti, Carlos H.C. | Rasera, Luciane
Objective-To determine the effect of experimental intraluminal distention on microvascular perfusion of the small colon in horses. Animals-6 mixed-breed healthy horses (mean age [+/- SD], 9.1 +/- 2 years). Procedure-Under general anesthesia, the small colon was exposed by celiotomy and 3 segments were demarcated. In 1 of these segments, intraluminal obstruction was created by placement of a latex balloon inflated to a pressure of 40 mm Hg (obstructed segment). The other segments were the sham-operated segment and the control segment. Microvascular perfusion was evaluated in the mucosal, submucosal, muscular, and serosal layers by injection of 15--µm-diameter colored microspheres into branches of the caudal mesenteric artery. Recovery of microspheres was performed by tissue digestion, washing, and centrifugation. Distribution of microspheres in the intestinal layers was evaluated by direct observation of stained frozen sections by light microscopy. Results-A significant reduction was observed in total microvascular perfusion of obstructed segments, which was 26.4% of that of control segments. This reduction was not evident in the mucosal layer. Conclusion and Clinical Relevance-Intraluminal distention of the equine small colon wall can promote ischemia by a reduction in microvascular perfusion in the intestinal wall. Intestinal layers do not seem to be affected to the same extent, because the absolute value for mucosal perfusion did not decrease in the obstructed segment.
显示更多 [+] 显示较少 [-]Comparison of the cardiopulmonary effects of anesthesia maintained by continuous infusion of romifidine, guaifenesin, and ketamine with anesthesia maintained by inhalation of halothane in horses
2002
McMurphy, Rose M. | Young, Lesley E. | Marlin, David J. | Walsh, Karen
Objective-To compare cardiopulmonary responses during anesthesia maintained with halothane and responses during anesthesia maintained by use of a total intravenous anesthetic (TIVA) regimen in horses. Animals-7 healthy adult horses (1 female, 6 geldings). Procedure-Each horse was anesthetized twice. Romifidine was administered IV, and anesthesia was induced by IV administration of ketamine. Anesthesia was maintained for 75 minutes by administration of halothane (HA) or IV infusion of romifidine, guaifenesin, and ketamine (TIVA). The order for TIVA or HA was randomized. Cardiopulmonary variables were measured 40, 60, and 75 minutes after the start of HA or TIVA. Results-Systolic, diastolic, and mean carotid arterial pressures, velocity time integral, and peak acceleration of aortic blood flow were greater, and systolic, diastolic, and mean pulmonary arterial pressure were lower at all time points for TIVA than for HA. Pre-ejection period was shorter and ejection time was longer for TIVA than for HA. Heart rate was greater for HA at 60 minutes. Minute ventilation and alveolar ventilation were greater and inspiratory time was longer for TIVA than for HA at 75 minutes. The PaCO2 was higher at 60 and 75 minutes for HA than for TIVA. Conclusions and Clinical relevance-Horses receiving a constant-rate infusion of romifidine, guaifenesin, and ketamine maintained higher arterial blood pressures than when they were administered HA. There was some indication that left ventricular function may be better during TIVA, but influences of preload and afterload on measured variables could account for some of these differences.
显示更多 [+] 显示较少 [-]