细化搜索
结果 1-2 的 2
Use of three-dimensional time-of-flight magnetic resonance angiography at 1.5 Tesla to evaluate the intracranial arteries of 39 dogs with idiopathic epilepsy
2019
Ishikawa, Chieko | Ito, Daisuke | Tanaka, Natsumi | Kitagawa, Masato
OBJECTIVE To assess visualization of the intracranial arteries and internal carotid artery (ICA) on 3-D time-of-flight (TOF) magnetic resonance angiography (MRA) images obtained at 1.5 T and to investigate factors that affect the image quality of those arteries in dogs. ANIMALS 39 dogs with idiopathic epilepsy. PROCEDURES Each dog underwent 3-D TOF MRA, and 5 pairs of intracranial arteries, the basilar artery, and both ICAs were evaluated. Each artery was assigned an image-quality score on a scale of 0 to 3, where 0 = poor and 3 = excellent. Multivariable regression analysis was used to assess whether age, body weight (BW), serum total cholesterol concentration, intracranial volume (ICV), and mean arterial pressure were significantly associated with the image quality of each vessel. RESULTS In all dogs, the image-quality score was 2 or 3 for the proximal middle cerebral arteries, basilar artery, and caudal aspect of the caudal communicating arteries. In some dogs, the rostral cerebellar arteries, rostral aspect of the caudal communicating arteries, and middle and rostral aspects of the ICA were poorly visualized. For various arteries, image quality was negatively associated with age and positively associated with BW and ICV. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that 3-D TOF MRA images obtained at 1.5 T did not consistently and clearly delineate the ICA and narrow or peripheral intracranial arteries of dogs; therefore, careful attention is required when such images are assessed. Patient age, BW, and ICV can also affect the image quality of some intracranial arteries on 3-D TOF MRA images.
显示更多 [+] 显示较少 [-]Morphometric evaluation of the portal vein by means of abdominal computed tomographic angiography in dogs free of vascular anomalies
2019
Rossanese, Matteo | Ferreira, Amy | Maddox, Thomas W.
OBJECTIVE To determine the mean diameter of the main portal vein (PV) in healthy dogs by use of CT angiography, identify any associations between PV diameter and certain dog characteristics, and validate a clinically valuable ratio for quantifying the size of the PV. ANIMALS 100 dogs with no hepatic, cardiac, or vascular anomalies that underwent abdominal CT angiography. PROCEDURES Diameters of the main PV, abdominal aorta (Ao), and caudal vena cava (CVC) were measured by 2 observers at a defined location on postcontrast CT angiographic images in axial, sagittal, and transverse planes. Dog characteristics were evaluated for associations with PV diameter, and a PV:Ao diameter ratio was calculated. Intraclass correlations were calculated to assess intra- and interobserver agreement in vessel diameter measurements. RESULTS Mean diameter values were 7.9 mm (range, 4.1 to 14.8 mm) for the PV, 8.9 mm (range, 3.7 to 13.7 mm) for the Ao, and 11.4 mm (range, 4.4 to 22.5 mm) for the CVC. The PV:Ao diameter ratio was 0.91 mm. The PV diameter was significantly associated with dog body weight but not with dog age, sex, or neuter status. Intra- and interobserver reliabilities for measurements of all 3 vessels were considered excellent (intraclass correlation coefficients > 0.85). CONCLUSIONS AND CLINICAL RELEVANCE Findings indicated that the PV:Ao diameter ratio was a repeatable measurement that may be useful for evaluating the size of the portal vasculature in dogs and possibly for distinguishing healthy PVs from abnormal PVs in dogs with hepatic vascular anomalies.
显示更多 [+] 显示较少 [-]