细化搜索
结果 1-3 的 3
Evaluation of a topical natural product formulation with Cantharanthus rosea and Cynodon dactylon for the treatment of squamous cell carcinoma in a gelding. A case study
2018
Shankar Ganesh, K. | Dasarathurao, S. | Shanthiravathanan, M.
A 20-year-old gelding suffering from 10 months of relapsing squamous cell carcinoma (SCC) on the penile sheath wastreated with a natural remedy as surgical intervention was not successful. A daily application of herbal ointment healed theulcer within 21 days. No relapse of ulcer was observed 3 months post heal.
显示更多 [+] 显示较少 [-]Evaluation of the survival of Vancomycin-resistant enterococci (VRE) isolated from chickens and possible inactivation by in-use concentration of Lindores-30, Ecos Timsen and Omnicide
2013
Adamu Abubakar Yerima | Latiffah Hassan | Zakaria Zunita
Vancomycin-resistant enterococci (VRE) are well-known ascendant nosocomial pathogens. The recent detection of epidemiologic strain
carrying vanA gene in the community of people working with animals and in chickens has brought to the forefront the potential public health danger posed by these organism. The farm environment is a major source of VRE persistence in poultry farms. We carried out survival test to test the survival of the VRE isolates on dry condition and surface test to evaluate the inactivation of the isolates by in-use concentration of commonly used disinfectants. In the survival test, all isolates survived for at least 4 weeks in
colony counts of (1.00 × 103 – 3.86 × 103 CFU/ml) under clean condition and (1.00 × 103 – 2.02 × 104) for soiled condition.
Those that were suspended in 5% BSA solution to mimic organic matter load as obtainable on farms survived for at least 8 weeks at (1.54 × 102 – 1.34 × 103 CFU/ ml). In the surface test, inactivation of VRE isolates by in-use concentration of Lindores®, Omnicide® and Ecos Timsen® was tested using the European surface test (EST). All the tested disinfectants were active against the VRE isolates on both the standard test surface (stainless steel) and our test surface (wooden). The results shows microbiocidal effects (ME) for test disinfectants, i.e. the log10 CFU of micro-organisms compared between test biocide and control treated with distilled water, after 7 min of exposure as follows; Lindores® active on both surfaces 5.24 and 3.17, Ecos Timsen® active significantly on steel 4.90 than wood 2.98 and Omnicide® significantly less active on stainless steel
2.40 than on wood 3.50.
显示更多 [+] 显示较少 [-]Characterization of Salmonella enteritidis strains
1993
Poppe, C. | McFadden, K.A. | Brouwer, A.M. | Demczuk, W.