细化搜索
结果 1-10 的 31
Modification of a haematoxylin, eosin, and natural saffron staining method for the detection of connective tissue
2021
Ceccopieri, Cassandra | Skonieczna, Joanna | Madej, Jan P.
The aim of our study was to optimise an existing staining procedure: haematoxylin-eosin saffron (HES). The method follows the classical haematoxylin and eosin protocol with the addition of a staining step using natural saffron to better identify the collagen fibres. The saffron solution was obtained by dissolving ground saffron stigmas in absolute alcohol. In order to test the HES method for its staining ability on four main types of collagen (I, II, III, and IV), specific tissues (skin, tooth, cartilage, aorta, spleen, and penis) were chosen. The procedure showed a sharp differentiation between muscle, stained red or pink, and connective tissue, stained bright yellow or orange. HES allows the diagnosis of reticulin fibrosis undetected in HE and in previous saffron staining procedures. HES represents an advantageous alternative to HE staining giving highly reproducible results with high diagnostic value.
显示更多 [+] 显示较少 [-]Influence of α-lipoic acid on morphology of organs of rabbits fed a high fat diet with the addition of oxidised rapeseed oil
2017
Stawiarska-Pięta Barbara | Zalejska-Fiolka Jolanta | Wyszyńska Magdalena | Kleczka Anna | Janiga Beata | Grzegorzak Natalia | Birkner Ewa
Introduction: The aim of the study was to assess the influence of α-lipoic acid (ALA) on the morphology of the aorta and liver of rabbits fed high fat diet with addition of oxidised (ORO) and non-oxidised rapeseed oil (N-ORO).
显示更多 [+] 显示较少 [-]Pilot study investigating the feasibility of mitral valve repair without aortic cross-clamping and cardioplegia
2020
Gordon-Evans, Wanda J. | Carney, John P. | Lahti, Mathew T. | Bianco, Richard W.
There is evidence that perfusing the heart with a heart and lung machine is less injurious than cross-clamping the aorta and administering cardioplegia during cardiac surgery. Although mitral valve replacement has been carried out without aortic cross-clamping and cardioplegia, it has been stated that cross-clamping is necessary in order to maintain visualization and a motionless surgical field for mitral valve repair. The purpose of this study was to determine the surgical feasibility of mitral valve repair without cross-clamping the aorta and using cardioplegia. Our hypothesis was that a completely bloodless and motion-free field would not be necessary to carry out mitral valve repair with annuloplasty and synthetic chordae tendineae sutures. Papillary muscles, chordae tendineae, annulus, and mitral valve leaflets were all readily visualized. Chordae tendineae sutures were used and annuloplasty was conducted without visual obstruction or motion interference. Our results show that mitral valve repair is feasible without cross-clamping the aorta and using cardioplegia.
显示更多 [+] 显示较少 [-]Correlation of the ratio of caudal vena cava diameter and aorta diameter with systolic pressure variation in anesthetized dogs
2016
Meneghini, Caterina | Rabozzi, Roberto | Franci, Paolo
OBJECTIVE To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was performed. RESULTS 28 measurements were obtained. The correlation coefficient was 0.86 (95% confidence interval, 0.72 to 0.93). Mean ± SD SPV and CVC-to-Ao ratio before bolus administration were 7 ± 2 mm Hg and 0.52 ± 0.16, respectively. Mean ± SD SPV and CVC-to-Ao ratio after bolus administration were 2 ± 0.6 mm Hg and 0.91 ± 0.13, respectively. CONCLUSIONS AND CLINICAL RELEVANCE In this study, the CVC-to-Ao ratio was a feasible, noninvasive ultrasonographically determined value that correlated well with SPV.
显示更多 [+] 显示较少 [-]Effects of medetomidine-midazolam-fentanyl IV bolus injections and its reversal by specific antagonists on cardiovascular function in rabbits
2010
Baumgärtner, Christine | Bollerhey, Melanie | Ebner, Johanna | Schuster, Tibor | Henke, Julia | Erhardt, Wolf
The objective of this study was to investigate the short-term cardiovascular effects of intravenous (IV) medetomidine-midazolam-fentanyl (MMF) injections in the rabbit using vascular ultrasonography and echocardiography.Anesthesia with MMF was induced intramuscularly (IM) in 8 female New Zealand White rabbits before 3 defined bolus injections of MMF were given IV. Before and for 10 min after each MMF injection the following vascular variables [at the left common carotid artery (ACC) after the first injection and at the abdominal aorta (AA) after the second injection]: vessel diameter (D), peak systolic, minimum diastolic, end-diastolic and average blood flow velocities (psBFV, mdBFV, edBFV, Vave), average volumetric flow (VFave), resistance index (RI) and pulsatility index (PI) and other clinical variables: mean arterial pressure (MAP), heart rate (HR), peripheral arterial oxygen saturation and end-tidal CO2 were recorded. Echocardiography was used after the third injection to investigate changes in cardiac parameters. Additionally, hemodynamic effects were observed at the ACC after complete subcutaneous antagonism of anesthesia by atipamezole-flumazenil-naloxone (AFN) until recovery of the animals. Medetomidine-midazolam-fentanyl IV caused a significant decrease of blood flow velocity in both investigated vessels which was associated with a significant decrease of HR and cardiac performance indicated by the decrease of FS and average volumetric blood flow. Mean arterial pressure significantly increased after each MMF injection; whereas, it significantly decreased after AFN injection. Therefore, MMF and AFN should be carefully used in rabbits and may not be suitable in patients with ventricular dysfunction.
显示更多 [+] 显示较少 [-]Vasorelaxant and hypotensive effects of trazodone in Guinea pig
2005
Kim, S.J. (Chonbuk National University, Jeonju, Republic of Korea) | Kang, H.S. (Chonbuk National University, Jeonju, Republic of Korea) | Kim, J.S. (Chonbuk National University, Jeonju, Republic of Korea), E-mail: kimjs@chonbuk.ac.kr
We studied the effects of trazodone on arterial blood pressure in anesthesized guinea pigs, and on vascular responses in isolated thoracic aorta. Trazodone produced a concentration-dependent relaxation in phenylephrine-precontracted endothelium intact (+E) rings, but not in a KCl-precontracted aortic rings. These relaxant effects of trazodone on +E rings were siginificantly greater than those on denuded (-E) rings. The trazodone-induced relaxation was suppressed by gilbenclamide and tetrabutylammonium, but not by N(G)-nitro-L-arginine (L-NNA), N(omega)-nitro-L-arginine methyl ester (L-NAME), methylene blue (MB), nifedipine, indomethacin, 2-nitro-4-carboxyphenyl-n,n-diphenylcarbamate (NCDC) and clotrimazole. In vivo, infusion of trazodone elicited a significant decrease in arterial blood pressure.
显示更多 [+] 显示较少 [-]Effect of hypertonic saline solution on left ventricular afterload in normovolumic dogs
1995
Constable, P.D. | Muir, W.W. III. | Binkley, P.F.
The effects of hypertonic saline solution (HSS) and hyperosmotic dextrose (HD; 2,400 mosm/L, 4 ml/kg of body weight) on left ventricular afterload were determined in normovolumic, chloralose-anesthetized, autonomically blocked dogs (n = 8). Solutions were infused IV over 3 minutes. Left ventricular afterload was assessed by use of a dual-tipped micromanometer catheter with an electromagnetic fluid-velocity sensor located in the ascending aorta, and the impedance spectrum was calculated after Fourier analysis of signal-averaged aortic pressure and flow signals. Hypertonic saline solution and HD decreased peripheral resistance, reflection coefficient at zero frequency, and frequency of the first zero crossing of the phase angle for 3 to 5 minutes after either fluid was administered. Characteristic impedance was not altered by HSS or HD. These impedance spectrum changes indicate transient vasodilatation and afterload reduction. We conclude that the vascular effect of an ionic hyperosmotic solution (HSS) is similar to that of a nonionic hyperosmotic solution (HD), and that HSS and HD transiently decrease afterload in normovolumic dogs. The duration of the afterload reduction after HSS administration appeared to be too short to be of great clinical benefit.
显示更多 [+] 显示较少 [-]Use of pulsed-wave Doppler echocardiography to determine aortic and pulmonary velocity and flow variables in clinically normal dogs
1991
Brown, D.J. | Knight, D.H. | King, R.R.
Transcutaneous pulsed-wave Doppler echocardiography was used to obtain velocity signals from the aortic and pulmonary roots of clinically normal adult dogs tranquilized with acepromazine. Doppler-derived variables included peak ejection velocity, ejection time, and velocity-time integral. The cross-sectional areas of the left and right ventricular outflow tracts were estimated from diameters of the respective orifices measured from two-dimensional echocardiographic images. These data were used to calculate stroke volume and cardiac output for each ventricle. Linear, single variable regressions of ejection time, velocity-time integral, and peak velocity with body weight showed no significant correlations. Significant correlations existed between body weight and estimated left and right ventricular stroke volume and cardiac output. A close correspondence existed between pulmonary and aortic determinations of velocity-time integral, stroke volume, and cardiac output. These results provide an initial framework for interpretation of clinical data by veterinary cardiologists.
显示更多 [+] 显示较少 [-]Hemodynamic effects of high-frequency oscillatory ventilation in halothane-anesthetized dogs
1989
Bednarski, R.M. | Muir, W.W. III.
Hemodynamic effects of spontaneous ventilation, intermittent positive-pressure ventilation (IPPV), and high-frequency oscillatory ventilation (HFOV) were compared in 6 dogs during halothane anesthesia. Anesthesia was induced with IV thiamylal Na and was maintained with halothane (end-tidal concentration, 1.09%). During placement of catheters, dogs breathed spontaneously through a conventional semiclosed anesthesia circuit. Data were collected, and dogs were mechanically ventilated, using IPPV or HFOV in random order. Ventilation was adjusted to maintain PaCO2 between 38 and 43 mm of Hg during IPPV and HFOV. Cardiac index, aortic blood pressure, and maximum rate of increase of left ventricular pressure were significantly (P less than 0.05) less during HFOV than during spontaneous ventilation, whereas right atrial and pulmonary artery pressure were significantly greater during HFOV than during spontaneous ventilation. During IPPV, only the maximum rate of increase of left ventricular pressure was significantly less than that during spontaneous ventilation.
显示更多 [+] 显示较少 [-]Perfusion- and diffusion-weighted magnetic resonance imaging of the liver of healthy dogs
2016
Del Chicca, Francesca | Schwarz, Andrea | Grest, Paula | Kircher, Patrick R.
OBJECTIVE To describe the perfusion and diffusion characteristics of the liver in healthy dogs as determined by morphological, perfusion-weighted, and diffusion-weighted MRI. ANIMALS 11 healthy adult Beagles. PROCEDURES Each dog was anesthetized and underwent morphological, perfusion-weighted, and diffusion-weighted MRI of the cranial aspect of the abdomen. On the MRI images, a region of interest (ROI) was established for each of 6 structures (aorta, caudal vena cava, portal vein, hepatic parenchyma, splenic parenchyma, and skeletal [epaxial] muscle). The signal intensity was determined, and a time-intensity curve was generated for each ROI. The apparent diffusion coefficient (ADC) was calculated for the hepatic and splenic parenchyma in diffusion-weighted MRI images, and the normalized ADC for the liver was calculated as the ratio of the ADC for the hepatic parenchyma to the ADC for the splenic parenchyma. Dogs also underwent abdominal ultrasonography, and ultrasound-guided fine-needle aspirate samples and biopsy specimens were obtained from the liver for cytologic and histologic examination. RESULTS Cytologic and histologic results suggested that the liver was clinically normal in all dogs. Perfusion-weighted MRI parameters varied among the 6 ROIs. The mean ± SD ADC of the hepatic parenchyma was 0.84 × 10(−3) mm2/s ± 0.17 × 10(−3) mm2/s, and the mean normalized ADC for the liver was 1.8 ± 0.4. CONCLUSIONS AND CLINICAL RELEVANCE Results provided preliminary baseline information about the diffusion and perfusion characteristics of the liver in healthy dogs. Additional studies on dogs of various breeds with and without hepatopathies are necessary to validate and refine these findings.
显示更多 [+] 显示较少 [-]