细化搜索
结果 1-10 的 28
Ultrasonography of the lungs, pleura, and mediastinum in healthy cows.
1996
Braun U. | Sicher D. | Pusterla N.
Study on body measurement of fetuses and neonates in Korean native goats.
1988
Kim C.S. | Choe S.Y. | Chung H.S. | Kim T.S.
The measurement was investigated with 18 heads of fetus (60, 90, 120 days of gestation) and neonate in Korean native goats. The crown-rump length of fetuses at 60, 90, 120 days of gestation and neonate was 8.71, 20.83, 31.10 and 34.93 cm, respectively. The length of small intestine at 60, 90, 120 days of gestation and neonate was 32.28, 157.10, 303.52 and 475.06 cm, respectively. The length of large intestine at 60, 90, 120 days of gestation and neonate was 9.20, 37.70, 82.06 and 94.46 cm, respectively. The head length at 60, 90, 120 days of gestation and neonate was 2.93+-0.07, 6.67+-0.13, 8.84+-0.51 and 9.76+-0.44 cm, respectively. The width of the head at 60, 90, 120 days of gestation and neonate was 2.20+-0.13, 4.45+-0.11, 5.33+-0.20 and 5.51+-0.32 cm, respectively.
显示更多 [+] 显示较少 [-]Possibilities Of Estimating Body Weight From Different Body Measurements In Hair Goat Using Different Regression Models 全文
2019
Demiraslan, Yasin | Gurbuz, Iftar | Gurkan Dilek, Omer | Ozudogru, Sukru | Ozgel, Ozcan
In the study, the data obtained to describe the body characteristics of the Hairpin were utilized in the businesses that were registered with Karaman Province Breeding Sheep Goat Breeders Association. Body weights of 130 goats, 2, 3, 4, 5, 6 and 7 years old and 50 goats, 2, 3 and 4 years old, selected by simple random sampling method were used in the data of total 900. In the study, Pearson correlation coefficient for variables providing parametric test prerequisites, and Spearman correlation analysis for variables not providing parametric test prerequisites. In the regression analysis, "live weight" dependent variable and other variables were determined as independent variables and parametric and nonparametric regression methods were applied. Univariate and multivariable regression models were applied for the whole data set. When all analyzes are evaluated, univariate regression models give lower determination coefficients (R2) than multivariate models. In this case, it has been deemed appropriate to use a multivariate regression model instead of a univariate model in order to make a correct prediction.However, in practice, univariate Quadratic or Cubic regression methods can be used for researchers.
显示更多 [+] 显示较少 [-]Evaluation of a ferret-specific formula for determining body surface area to improve chemotherapeutic dosing 全文
2015
OBJECTIVE To use CT-derived measurements to create a ferret-specific formula for body surface area (BSA) to improve chemotherapeutic dosing. ANIMALS 25 adult ferrets (19 live and 6 cadavers). PROCEDURES Live subjects were weighed, and body measurements were obtained by each of 3 observers while ferrets were awake and anesthetized. Computed tomography was performed, and a 3-D surface model was constructed with open-source imaging software, from which BSA was estimated. The CT-derived values were compared with BSA calculated on the basis of the traditional tape method for 6 cadavers. To further validate CT analysis software, 11 geometric shapes were scanned and their CT-derived values compared with those calculated directly via geometric formulas. Agreement between methods of surface area estimation was assessed with linear regression. Ferret-specific formulas for BSA were determined with nonlinear regression models. RESULTS Repeatability among the 3 observers was good for all measurements, but some measurements differed significantly between awake and anesthetized ferrets. Excellent agreement was found between measured versus CT-derived surface area of shapes, traditional tape– versus CT-derived BSA of ferret cadavers, and CT-derived BSA of cadavers with and without monitoring equipment. All surface area formulas performed relatively similarly. CONCLUSIONS AND CLINICAL RELEVANCE CT-derived BSA measurements of ferrets obtained via open-source imaging software were reliable. On the basis of study results, the recommended formula for BSA in ferrets would be 9.94 × (body weight)2/3; however, this represented a relatively minor difference from the feline-derived formula currently used by most practitioners and would result in little practical change in drug doses.
显示更多 [+] 显示较少 [-]Ultrasonographic and biometric evaluation of the eye and orbit of dogs
1989
Cottrill, N.B. | Banks, W.J. | Pechman, R.D.
The normal B-scan ultrasonographic anatomic features of the eye and orbit of mesocephalic and dolichocephalic dogs were described. The B-scan appearance of ocular and orbital structures correlated well with the visual morphologic features of the specimens. The eyes of mesocephalic and dolichocephalic dogs were measured by use of ultrasonographic methods; those measurements were compared with direct measurements of the specimens. The 2-tailed Student t-test was used for all statistical analyses (P = 0.05). Measurements made included mid-cornea to anterior lens surface, lens thickness, vitreous body (posterior lens surface to retina), and axial globe length. The A-scan measurements of all 4 ocular distances were significantly different, compared with direct measurements. The B-scan measurements of mid-cornea to anterior lens surface, lens thickness, and vitreous body were significantly different from direct measurements; however, there was no significant difference between B-scan and direct measurements of axial globe length. There was no significant difference between A- and B-scan measurements. These findings suggest that A- and B-scan measurements are similar and that B-scan measurements are reasonably accurate for axial globe determination. Several variables were compared by B-scan and direct measurement methods. The axial globe length of dolichocephalic dogs was significantly longer than that of mesocephalic dogs. The axial globe length of male and female dogs was not significantly different in mescephalic or dolichocephalic dogs. There was no difference in the axial globe length of right and left eyes in mesocephalic or dolichocephalic dogs.
显示更多 [+] 显示较少 [-]Multiple regression analysis, using body size and cardiac cycle length, in predicting echocardiographic variables in dogs
1988
Jacobs, G. | Mahjoob, K.
A significant (P less than 0.0001) positive correlation was demonstrated between left ventricular internal chamber dimension in diastole or systole and body weight, body surface area, cycle length, and the square root of cycle length. On the basis of adjusted coefficients of determination, multiple regression analysis, using body weight or body surface area and cycle length or the square root of cycle length, was superior to separate simple regression with these variables in accounting for variations in left ventricular internal chamber dimensions. Shortening fraction had a significant (P less than 0.0001) negative correlation and left ventricular free wall measurements had a significant (P less than 0.0001) positive correlation to body weight and body surface area. For these echocardiographic variables, correlation to the square root of cycle length was insignificant (P greater than 0.05), and a multiple regression model was not helpful in developing confidence intervals. Septal wall measurements were not correlated with body weight, body surface area, cycle length, or the square root of cycle length.
显示更多 [+] 显示较少 [-]Noninvasive measurements of body composition and body water via quantitative magnetic resonance, deuterium water, and dual-energy x-ray absorptiometry in cats 全文
2013
Zanghi, Brian M. | Cupp, Carolyn J. | Pan, Yuanlong | Tissot-Favre, Delphine G. | Milgram, North W. | Nagy, Tim R. | Dobson, Howard
Objective: To compare quantitative magnetic resonance (QMR), dual-energy x-ray absorptiometry (DXA), and deuterium oxide (D2O) dilution methods for measurement of total body water (TBW), lean body mass (LBM), and fat mass (FM) in healthy cats and to assess QMR precision and accuracy. Animals: Domestic shorthair cats (58 and 32 cats for trials 1 and 2, respectively). Procedures: QMR scans of awake cats performed with 2 units were followed by administration of D2O tracer (100 mg/kg, PO). Cats then were anesthetized, which was followed by QMR and DXA scans. Jugular blood samples were collected before and 120 minutes after D2O administration. Results: QMR precision was similar between units (coefficient of variation < 2.9% for all measures). Fat mass, LBM, and TBW were similar for awake or sedated cats and differed by 4.0%, 3.4%, and 3.9%, respectively, depending on the unit. The QMR minimally underestimated TBW (1.4%) and LBM (4.4%) but significantly underestimated FM (29%), whereas DXA significantly underestimated LBM (9.2%) and quantitatively underestimated FM (9.3%). A significant relationship with D2O measurement was detected for all QMR (r2 > 0.84) and DXA (r2 > 0.84) measurements. Conclusions and Clinical Relevance: QMR was useful for determining body composition in cats; precision was improved over DXA. Quantitative magnetic resonance can be used to safely and rapidly acquire data without the need for anesthesia, facilitating frequent monitoring of weight changes in geriatric, extremely young, or ill pets. Compared with the D2O dilution method, QMR correction equations provided accurate data over a range of body compositions.
显示更多 [+] 显示较少 [-]Heritability of the depth of the opening of the ciliary cleft in Samoyeds
1995
Ekesten, B. | Torrang, I.
Ocular examination, including gonioscopy and ultrasonographic biometry (biological measurement), was performed in healthy, purebred Samoyeds. When the dogs were subclassified according to the degree of kinship with cases of primary angle-closure glaucoma, it was found that the opening of the ciliary cleft was wider in dogs less related to dogs with primary angle-closure glaucoma than in more closely related dogs. Furthermore, multivariate analysis of the material indicated that parentage of a dog has a substantial effect on the intraocular distances studied in this investigation (relative depth of the opening of the ciliary cleft, relative corneal thickness, relative anterior chamber depth, relative lens thickness, and relative length of the vitreous body). Finally, heritability of the relative depth of the opening of the ciliary cleft was estimated at 56% and that of the common environmental factor at 19%. The results are indicative of a hereditary component in primary angle-closure glaucoma in the Samoyed breed.
显示更多 [+] 显示较少 [-]Ultrasonographic morphology of the bicipital tendon and bursa in clinically normal Quarter Horses
1995
The bicipital tendons and bursae of 25 healthy adult Quarter Horses were ultrasonographically examined. Cross-sectional images of the right and left bicipital tendons were obtained from each horse, using a 7.5-MHz transducer held in the frontal plane at the point of the shoulder. The bicipital tendon at the point of the shoulder appeared as a bilobate structure overlying the echogenic surface of the humerus. Median distance from the skin surface to the cranial surface of the tendon on the medial sagittal plane of the tendon was 23 mm (range, 16.5 to 30 mm); median distance on the lateral sagittal plane was 14 mm (range, 8.5 to 19 mm). Median distance from the skin surface to the tendon on the midsagittal plane of the tendon was 17 mm (range, 10.5 to 22 mm). Median cranial-to-caudal widths of the lateral and medial lobes of the tendon at their greatest dimensions were 20.5 mm (range, 18 to 27.5 mm) and 16 mm (range, 13 to 20.5 mm), respectively. The median cranial-tocaudal width of the central (midsagittal) portion of the tendon was 10 mm (range, 7 to 13.5 mm). The bicipital bursa was less than or equal to 3 mm wide at all locations at which it was measured. Ultrasonographic imaging was easily performed and allowed evaluation of the bicipital tendon, bursa, and surface of the underlying humerus.
显示更多 [+] 显示较少 [-]Cannulation of a lateral ventricle in the brain of Holstein calfs
1995
Ames, N.K. | Chapin, L.T. | Gaynor, P.J.
A surgical technique was developed for implanting a flexible polyurethane cannula in a lateral ventricle in the brain of calves. Initially, measurements were made on 25 calves at necropsy to develop equations for calculating coordinates for cannula placement. The distance (cm) caudal, in the sagittal plane, from the coronal suture line to the center of a hole to be drilled in the parietal bone of the skull was: 0.73 + (0.00925 X body weight [kg]). The distance (cm) lateral from the midline to the center of the hole to be drilled was: 0.018 + (0.6464 X distance caudal). The depth (cm) from the surface of the skull to the dorsal surface of the lateral ventricle was: 2.29 + (0.0159 X body weight [kg]). Surgery was subsequently performed on 17 calves. A 5-mm-diameter hole was drilled through the skull with a hand trephine at coordinates derived from the aforementioned regression equations. A polyurethane cannula (total length, 30 cm; 1 mm ID; 2 mm OD) covering a stainless-steel 20-gauge blunt-tipped needle (stylet) was lowered through the brain and into a lateral ventricle at an angle of 20.5 degrees relative to the frontal bones of the skull. The blunt-tipped needle was then removed, and CSF was allowed to drip from the cannula to verify placement. One stainless-steel screw was inserted 0.6 cm medial, and another was inserted 0.6 cm caudal to the hole in the skull. The area around the cannula, bone screws, and hole in the skull was covered with dental acrylic (approx 2 cm in diameter) to stabilize the cannula. With minimal restraint of calves, injection of substances into and withdrawal of CSF from a lateral ventricle of the brain were possible in most calves for at least 6 weeks after surgery was performed.
显示更多 [+] 显示较少 [-]