细化搜索
结果 1-2 的 2
Comparison of two multiplex PCR assays for the detection of Listeria spp. and Listeria monocytogenes in biological samples
2016
Budniak, Sylwia | Kędrak-Jabłońska, Agnieszka | Szczawińska, Anna | Reksa, Monika | Krupa, Marek | Szulowski, Krzysztof
Introduction: The aim of the study was to optimise and compare two multiplex PCR assays for the detection of Listeria spp. and Listeria monocytogenes in biological samples including the liver, brain, and blood. Material and Methods: Three strains of L. monocytogenes and single strains of each of the species: L. ivanovii, L. innocua, L. grayi, L. welshimeri, and L. seeligeri were used. Additionally, five other species of bacterium were used to evaluate the specificity of the tests. Results: Specific amplification products were obtained for both multiplex PCR assays, which confirmed the tested strains as Listeria spp. and L. monocytogenes, respectively. Isolates of other species did not yield PCR products. Conclusion: Both multiplex PCR assays proved to be significantly sensitive and highly-specific methods for the detection of Listeria strains.
显示更多 [+] 显示较少 [-]Comparison of visual metric and planimetry methods for brain tumor measurement in dogs
2016
Thomson, Chris B. | Haynes, Kevin H. | Pluhar, G Elizabeth
OBJECTIVE To compare the orthogonal diameter (visual metric) method against a manual perimeter tracing (planimetry) method to measure volume of brain tumors in dogs by use of MRI scans. SAMPLE 22 sets of MRI brain scans pertaining to 22 client-owned dogs with histologically confirmed glioma. PROCEDURES MRI scans were reviewed by 2 operators, and scans revealing tumors with a degree of gadolinium enhancement that allowed discrimination between tumor tissue and healthy parenchyma were used. Each operator calculated tumor volume for each set of scans twice by use of visual metric and planimetry methods. Inter- and intraoperator variability were assessed by calculation of an agreement index (AI). RESULTS Mean ± SD intraoperator AIs were 0.79 ± 0.24 for the visual metric method and 0.89 ± 0.17 for the planimetry method. Intraoperator variability for both operators was significantly less when the planimetry method was used than when the visual metric method was used. No significant differences were identified in mean interoperator AI between visual metric (0.68 ± 0.28) and planimetry (0.67 ± 0.31) methods. CONCLUSIONS AND CLINICAL RELEVANCE The lower intraoperator variability achieved with the planimetry versus visual metric method should result in more precise volume assessments when the same operator performs multiple volume measurements of brain tumors in dogs. Equivocal results for interoperator variability may have been due to method variance or inadequate preliminary training. Additional studies are needed to evaluate the suitability of planimetry for assessing response to treatment.
显示更多 [+] 显示较少 [-]