细化搜索
结果 31-40 的 123
Dobutamine-induced augmentation of cardiac output does not enhance respiratory gas exchange in anesthetized recombent healthy horses.
1986
Swanson C.R. | Muir W.W. III
Arterial to end-tidal CO2 tension and alveolar dead space in halothane- or isoflurane-anesthetized ponies.
1985
Meyer R.E. | Short C.E.
Evaluation of the wick catheter as used to measure intracompartmental muscle pressure in equine muscle.
1985
McDonnell W.N. | Pascoe P.J. | Lindsay W.A. | Burgess M.L.F.
Theophylline and dyphylline pharmacokinetics in the horse.
1985
Ayres J.W. | Pearson E.G. | Riebold T.W. | Chang S.F.
High resolution protein electrophoresis of equine cerebrospinal fluid.
1997
Furr M. | Chickering W.R. | Robertson J.
Segmental variations of in vitro mechanical properties in equine superficial digital flexor tendons.
1996
Crevier N. | Pourcelot P. | Denoix J.M. | Geiger D. | Bortolussi C. | Ribot X. | Sanaa M.
In vitro evaluation of four methods of attaching transfixation pins into a fiberglass cast for use in horses.
1996
McClure S.R. | Watkins J.P. | Hogan H.A.
Mural blood flow distribution in the large colon of horses during low-flow ischemia and reperfusion.
1995
Moore R.M. | Hardy J. | Muir W.W.
Six horses were subjected to 3 hours of low-flow ischemia and 3 hours of reperfusion of the large colon. After induction of anesthesia, the large colon was exteriorized through a ventral midline celiotomy. Colonic blood flow was measured continuously, using Doppler ultrasonic flow probes placed on the colonic arteries supplying the dorsal and ventral colons and was allowed to stabilize for 15 to 30 minutes after instrumentation. Low-flow ischemia was induced by reducing colonic arterial blood flow to 20% of baseline (BL) flow. Colonic mucosal, seromuscular, and full-thickness blood flow were determined on a tissue-weight basis by injecting colored microspheres proximally into the colonic artery supplying the ventral colon. Reference blood samples were obtained at a known flow rate from the colonic artery and vein at a site more distal to the site of injection. Left ventral colon biopsy specimens were harvested at BL, 3 hours of ischemia, and 15 minutes of reperfusion. Blood and tissue samples were digested and filtered to collect the microspheres, and dimethylformamide was added to release the colored dyes. Dye concentration in blood and tissue samples was measured by use of spectrophotometry, and tissue-blood flow was calculated. Data were analyzed, using two-way ANOVA for repeated measures; statistical significance was set at P < 0.05. Doppler blood flow decreased to approximately 20% of BL, whereas microsphere blood flow ranged between 13.7 and 15.5% of BL at 3 hours of ischemia. Doppler-determined blood flow increased immediately on restoration of blood flow, reached 183% of BL at 15 minutes of reperfusion, and remained at or above BL throughout 3 hours of reperfusion. This reactive hyperemia was also detected, using the colored microspheres; blood flow increased to 242 and 327% of BL at 15 minutes of reperfusion in the mucosal and seromuscular layers, respectively.
显示更多 [+] 显示较少 [-]Pharmacologic interaction of furosemide and phenylbutazone in horses.
1995
Hinchcliff K.W. | McKeever K.H. | Muir W.W. III. | Sams R.A.
The effect of premedication with phenylbutazone on systemic hemodynamic and diuretic effects of furosemide was examined in 6 healthy, conscious, mares. Mares were instrumented for measurement of systemic hemodynamics, including cardiac output and pulmonary arterial, systemic arterial, and intracardiac pressures, and urine flow. Each of 3 treatments was administered in a randomized, blinded study; furosemide (1 mg/kg of body weight, IV) only, phenylbutazone (8.8 mg/kg PO, at 24 hours and 4.4 mg/kg IV, 30 minutes before furosemide) and furosemide, or 0.9% NaCl. Phenylbutazone administration significantly attenuated, but did not abolish, the diuretic effect of furosemide. Phenylbutazone completely inhibited the immediate effect of furosemide on cardiac output, stroke volume, total peripheral resistance, and right ventricular peak pressure. Premedication with phenylbutazone did not inhibit equally the diuretic and hemodynamic effects of furosemide, indicating that some of furosemide's hemodynamic effects are mediated by an extrarenal activity of furosemide.
显示更多 [+] 显示较少 [-]Sonographic-anatomic correlation and imaging protocol for the kidneys of horses.
1995
Hoffmann K.L. | Wood A.K.W. | McCarthy P.H.
Sonographic and anatomic observations were made of the kidneys of 23 Thoroughbreds or Standardbreds. In an in vitro study of 16 horses, precise correlations were established between the gross anatomic features of the kidneys and their sonographic appearance in images obtained in dorsal, sagittal, transverse, and transverse oblique anatomic planes. The renal cortex had a uniformly mottled echogenicity, and the renal medulla was relatively hypoechogenic, compared with the cortex. Acoustic anisotropy was observed in the cortex and medulla of the cranial and caudal extremities of each kidney. The distinctive renal pelvis was seen in the transverse plane as an echogenic pair of diverging lines that lead to the crescent shaped renal crest in the lateral half of the kidney. In images made in the sagittal plane, the renal pelvis was seen as a pair of parallel echogenic lines separated by the moderately echogenic line of the renal crest. The terminal recesses were best seen in the transverse oblique views of each extremity, where they appeared as moderately echogenic lines in the medulla of the cranial and caudal extremities. The interlobar vessels were represented as irregular echogenic lines in the medulla, and the arcuate vessels were seen as echogenic points at the corticomedullary junction. At the hilus, the renal artery or its branches was located cranial to the renal vein, which in turn was cranial to the position of the proximal portion of the ureter. In an in vivo study of 7 horses, sonographic images of the right kidney were obtained in the sagittal, transverse, and transverse oblique anatomic planes in all horses, with the transducer positioned at the 15th, 16th, or 17th intercostal space; images in the dorsal plane were obtained, however, in only 3 of the horses. For the left kidney, sonographic images were obtained in each of the anatomic planes when the transducer was positioned at the 16th or 17th intercostal space or the paralumbar fossa.
显示更多 [+] 显示较少 [-]