细化搜索
结果 1-10 的 28
Evaluation of an automated system for hemoglobin measurement in animals.
1992
Callan M.B. | Giger U. | Oakley D.A. | Scotti M.V. | Shofer F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
显示更多 [+] 显示较少 [-]Bioelectrical impedance and zoometry for body composition analysis in domestic cats.
1992
Stanton C.A. | Hamar D.W. | Johnson D.E. | Fettman M.J.
Zoometric measurements and bioelectrical impedance analysis were evaluated as methods of body composition determination in healthy cats. Zoometric and impedance measurements were taken on 22 anesthetized adult cats of various ages, genders, breeds, and body weights. The cats were then euthanatized. The bodies were processed through a tissue homogenizer and free-catch specimens were taken, freeze-dried, and analyzed for total body water, protein, fat, potassium, and ash content. Stepwise regression analysis was implemented to identify statistically significant relationships between the chemically determined dependent variables (total body water, protein, potassium, fat-free mass, fat mass, and percent body fat) and the zoometric measurements, with or without bioelectrical impedance analysis. Statistical analysis revealed high correlations between the dependent variables and the corresponding predicted values of those variables. Body weight alone was a poor predictor of body composition in these cats. On the basis of these findings, we suggest that zoometric and bioelectrical impedance measurements may serve as practical, noninvasive, simple, and accurate methods for estimating body composition in domestic cats.
显示更多 [+] 显示较少 [-]Evaluation of the Doppler ultrasonic method of measuring systolic arterial blood pressure in cats.
1992
Grandy J.L. | Dunlop C.I. | Hodgson D.S. | Curtis C.R. | Chapman P.L.
The accuracy of the Doppler technique for indirect systolic blood pressure measurement was assessed in 16 anesthetized cats. Eight cats were anesthetized with isoflurane and 8 were anesthetized with halothane. Anesthetic depth and mode of ventilation were varied to obtain a wide range of arterial blood pressure. A Doppler transducer was placed on the palmer surface of the left fore-limb over the common digital branch of the radial artery to detect blood flow, and a blood pressure monitoring cuff with a width 37% the limb circumference was placed half way between the elbow and the carpus. To enable direct arterial pressure measurements, the left femoral artery was catheterized and the blood pressure waveforms recorded simultaneously. Systolic blood pressure measured by use of the Doppler ultrasonic technique was significantly lower than that obtained from the femoral artery catheter. Using linear regression, we determined a clinically useful calibration adjustment for Doppler indirect blood pressure measurement in cats: femoral systolic pressure = Doppler systolic pressure + 14 mm of Hg.
显示更多 [+] 显示较少 [-]Efficacy of a chewable formulation of ivermectin against a mixed infection of Ancylostoma braziliense and Ancylostoma tubaeforme in cats
1992
Nolan, T.J. | Niamatali, S. | Bhopale, V. | Longhofer, S.L. | Schad, G.A.
The efficacy of a beef-based, chewable formulation of ivermectin against a mixed infection of Ancylostoma braziliense and A tubaeforme was determined in cats. Ivermectin administered orally at approximately 24 microgram/kg of body weight was 92.8% effective against adult A braziliense and 90.7% effective against adult A tubaeforme. The number of eggs per gram of feces had decreased 98.1% by 7 days after treatment. Clinical signs of hookworm disease also decreased after treatment. Location of adult parasites within the small intestine, percentage of infecting larvae that developed to the adult stage, and egg size in cats with infections of A braziliense and A tubaeforme were similar to those reported for cats with separate infections of either species.
显示更多 [+] 显示较少 [-]Urethral pressure response to alpha-adrenergic agonists and antagonist drugs in anesthetized healthy male cats
1992
Frenier, S.L. | Knowlen, G.G. | Speth, R.C. | Moore, M.P.
Urethral smooth muscle tone in response to treatment with phenylephrine, a selective alpha 1-adrenergic receptor agonist, and prazosin a selective alpha 1-adrenergic receptor antagonist, was evaluated in 12 anesthetized healthy adult sexually intact male cats. Intravenous administration of prazosin (20 to 30 micrograms/kg of body weight) decreased the average preprostatic and prostatic intraurethral pressure, compared with baseline and postphenylephrine (20 to 30 micrograms(kg) administration, values. Neither prazosin nor phenylephrine administration had an effect on functional urethral length. Results have implications for the pharmacologic management of lower urinary tract disorders in male cats.
显示更多 [+] 显示较少 [-]Characterization of a feline T-cell-specific monoclonal antibody reactive with a CD5-like molecule
1992
Ackley, C.D. | Cooper, M.D.
The 43 monoclonal antibody raised against feline T cells was found to react with a single-chain glycoprotein of Mr 72,000 that is present on most thymocytes, 60% of lymph node cells, 20% of splenocytes, and 45% of blood mononuclear cells. All CD4+ and CD8+ T cells were found to express the 43-reactive determinant, as did a small subpopulation of CD4-/CD8-/IgM- lymphocytes in the periphery. The 43-reactive determinant was not detected on B cells, macrophages, or other types of blood cells. The 43 antigen was phosphorylated in resting and activated T cells. Its expression was upregulated by stimulation with phorbol myristate acetate and with phytohemagglutinin. When added to concanavalin A-stimulated T-cell cultures in low concentrations, the 43 antibody was found to augment mitogenesis. The data indicate that this antibody may identify a CD5 homologue on feline T cells.
显示更多 [+] 显示较少 [-]Evaluation of an automated system for hemoglobin measurement in animals
1992
Callan, M.B. | Giger, U. | Oakley, D.A. | Scotti, M.V. | Shofer, F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
显示更多 [+] 显示较少 [-]Evaluation of serum fructosamine concentration as an index of blood glucose control in cats with diabetes mellitus
1992
Kaneko, J.J. | Kawamoto, M. | Heusner, A.A. | Feldman, E.C. | Koizumi, I.
Fructosamine, a glycated serum protein, was evaluated as an index of glycemic control in normal and diabetic cats. Fructosamine was determined manually by use of a modification of an automated method. The within-run precision was 2.4 to 3.2%, and the day-to-day precision was 2.7 to 3.1%. Fructosamine was found to be stable in serum samples stored for 1 week at 4 degrees C and for 2 weeks at -20 degrees C. The reference range for serum fructosamine concentration in 31 clinically normal colony cats was 2.19 to 3.47 mmol/L (mean, 2.83 +/- 0.32 mmol/L). In 27 samples from 16 cats with poorly controlled diabetes mellitus, the range for fructosamine concentration was 3.04 to 8.83 mmol/L (mean, 5.93 +/- 1.35 mmol/L). Fructosamine concentration was directly and highly correlated to blood glucose concentration. Fructosamine concentration also remained high in consort with increased blood glucose concentration in cats with poorly controlled diabetes mellitus over extended periods. It is concluded that measurement of serum fructosamine concentration can be a valuable adjunct to blood glucose monitoring to evaluate glycemic control in diabetic cats. The question of whether fructosamine can replace glucose for monitoring control of diabetes mellitus requires further study.
显示更多 [+] 显示较少 [-]Comparison of the immunoreactive plasma corticotropin and cortisol responses to two synthetic corticotropin preparations (tetracosactrin and cosyntropin) in healthy cats
1992
Peterson, M.E. | Kemppainen, R.J.
Plasma cortisol and immunoreactive (IR)-ACTH responses to 125 microg of tetracosactrin and cosyntropin--the formulation of synthetic ACTH available in Europe and the United States, respectively--were compared in 10 clinically normal cats. After administration of tetracosactrin or cosyntropin, mean plasma cortisol concentration reached a peak and plateaued between 60 and 120 minutes, then gradually decreased to values not significantly different from baseline concentration by 5 hours. Mean plasma IR-ACTH concentration reached a maximal value at 15 minutes after administration of tetracosactrin or cosyntropin and was still higher than baseline concentration at 6 hours. Difference between mean plasma cortisol and IR-ACTH concentrations for the tetracosactrin or cosyntropin trials was not significant at any of the sample collection times. Individual cats had some variation in the time of peak cortisol response after administration of either ACTH preparation. About half the cats had peak cortisol concentration at 60 to 90 minutes, whereas the remainder had the peak response at 2 to 4 hours. In general, however, peak cortisol concentration in the cats with delayed response was not much higher than the cortisol concentration at 60 to 90 minutes. Overall, these results indicate that tetracosactrin or cosyntropin induce a comparable, if not identical, pattern of adrenocortical responses when administered to healthy cats.
显示更多 [+] 显示较少 [-]Serum lipoprotein concentrations and hepatic lesions in obese cats undergoing weight loss
1992
Dimski, D.S. | Buffington, C.A. | Johnson, S.E. | Sherding, R.G. | Rosol, T.J.
Serum lipoprotein concentrations, routine serum biochemical values, and morphologic changes of the liver were evaluated in cats undergoing weight loss. Food was withheld from 6 obese and 6 control cats for 3 days (days 0 to 2), followed by feeding 50% of previous food intake for 26 days (days 3 to 28). Percutaneous liver biopsy specimens were obtained from all cats on days 0, 7, 14, and 28. Blood samples for serum biochemical analysis and lipoprotein profiles were obtained on days 0, 3, 7, 14, and 28. All cats lost weight throughout the study, and none developed signs of chemical illness, including those of idiopathic hepatic lipidosis syndrome. Serum total cholesterol concentrations decreased initially in all cats, but rapidly returned to normal after day 3 in obese cats, suggesting altered cholesterol metabolism during dietary restriction. Low-density lipoprotein concentrations decreased throughout the study in control cats, but were unchanged in obese cats. Examination of liver biopsy specimens from each cat revealed minimal lipid accumulation in all specimens, although some specimens contained hydropic degeneration.
显示更多 [+] 显示较少 [-]