细化搜索
结果 1-4 的 4
Clinicopathologic findings after experimental implantation of synthetic intraocular lenses in dogs
1993
Gilger, B.C. | Whitley, R.D. | McLaughlin, S.A. | Wright, J.C. | Boosinger, T.R.
Clinical findings indicate that canine eyes tolerate implantation of polymethylmethacrylate (PMMA) intraocular lenses (IOL) well, although inflammation and ocular damage attributable to the implants is not known. The use of silicone or polyhydroxyethylmethacrylate (HEMA) IOL has not been reported in dogs. In this study, 15 conditioned, mixed-breed dogs were allotted to 3 groups: 5 received PMMA IOL; 5 received silicone IOL; and 5 received HEMA IOL. The IOL optic was inserted into the anterior chamber of the right eye and anchored to the cornea. An identical surgical procedure was done on the left eye, except that no lens optic was inserted. Clinical examination and measurement of corneal thickness were done immediately prior to and after surgery. Aqueous humor samples were collected at the time of surgery and 28 days after surgery. Only mild and transient inflammation was observed in IOL-implanted eyes. On several postoperative days, it was found that PMMA IOL induced significantly greater corneal thickness, aqueous flare, anterior uveal irritation, and corneal edema than did other IOL. Significantly more anterior uveal irritation and increased aqueous humor protein concentration was observed with HEMA IOL than with PMMA or silicone IOL. Silicone IOL induced significantly less fibrin deposition than did PMMA or HEMA IOL.
显示更多 [+] 显示较少 [-]Use of biometry and keratometry for determining optimal power of intraocular lens implants in dogs
1991
Gaiddon, J. | Rosolen, S.G. | Steru, L. | Cook, C.S. | Peiffer, R. Jr
Axial length and corneal curvature were determined by use of A-scan ultrasonography and keratometry on both eyes of dogs of various breeds, sizes, and ages. Mean axial length was 20.43 +/- 1.48 mm; axial length was not related to age or sex, but was significantly greater (P = 0.047) in dogs of larger breeds. Mean corneal curvature was 39.94 +/- 2.61 diopters. Dogs of large breeds had significantly (P < 0.001) flatter corneas. Mild, roughly symmetric astigmatism was detected in a majority of dogs. Use of mean values in a theoretic artificial intraocular lens power equation suggests that aphakic dogs require an implant of approximately 40 diopters to achieve emmetropia.
显示更多 [+] 显示较少 [-]Refractive state of aphakic and pseudophakic eyes of dogs
1993
Davidson, M.G. | Murphy, C.J. | Nasisse, M.P. | Hellkamp, A.S. | Olivero, D.K. | Brinkmann, M.C. | Campbell, L.H.
Streak retinoscopy was performed by 5 ophthalmologists on 256 eyes (191 dogs) to determine their postoperative refractive state after cataract extraction. Aphakic and pseudophakic eyes that had been implanted with 1 of 5 intraocular lenses (IOL) with dioptric powers ranging from +14.5 to +38 diopters (D) were studied. By use of ANOVA, breed and body type of dog and individual performing refraction were found to have no detectable effect on final refractive state. Mean refractive state of aphakic eyes was +14.4 +/- 2.10 D. Mean refractive state for different IOL powers was as follows: +14.5 D IOL = +11.54 +/- 1.18 D (n = 13); +30 D IOL = + 5.15 +/- 1.18 D (n = 105); +34.0 D IOL = +3.5 D (n = 1); +36 D IOL +2.34 +/- 0.73 D 9 (n = 61); and +38 D IOL = +1.41 +/- 0.56 D (n = 28). Residual hyperopia ranged from +0.5 D to +2.5 D with +38 D IOL, and no eyes were myopic (overcorrected) by use of any of the IOL studied. linear regression analysis of refractive state on IOL power for aU dogs predicted that dioptric strength of +41.53 D was necessary to best approximate emmetropia for the population as a whole. Body type of the dog had only slight effect (< 1.0 D) on predicted optimal IOL power. Further linear regression analysis of the 7 breeds studied predicted variations from +39.62 to +43.14 D in IOL powers necessary to approximate emmetropia. Results of the study support the routine use of canine IOL with dioptric strength of approximately +41.5 D in circumstances in which preoperative biometry and keratometry are not practical. The findings further suggest that, for the specific population of dogs studied, most of the dogs could be corrected to near emmetropia by use of a small range of IOL dioptric strengths, irrespective of body type or breed.
显示更多 [+] 显示较少 [-]Effects of lipoxygenase inhibitors in a model of lens-induced uveitis in dogs
1989
Dziezyc, J. | Millichamp, N.J. | Rohde, B.H. | Baker, J.S. | Chiou, G.C.Y.
Uveitis was induced in dogs by intracameral injection of canine lens protein. The lipoxygenase inhibitors phenidone and norhydroguaiaretic acid, and dimethyl sulfoxide decreased fibrin production at 0.5 and 1 hour after induction uveitis. Phenidone and norhydroguaiaretic acid also inhibited the initial increase intraocular pressure early in the course of inflammation. Leukotriene B4 in the aqueous was measured by use of radioimmunoassay at 1 hour after inflammation. In control dogs, 230 to 1,700 pg of leukotriene B4/ml was measured; in dogs treated with phenidone, leukotriene, B4 was not measured.
显示更多 [+] 显示较少 [-]