细化搜索
结果 1-9 的 9
Evaluation of bending strength of five interdental fixation apparatuses applied to canine mandibles.
1993
Kern D.A. | Smith M.M. | Grant J.W. | Rockhill A.D.
Strength in bending was determined for inter. dental fixation apparatuses applied to hemimandibles obtained from 24 canine cadavers. Hemimandibles were osteotomized perpendicular to the long axis between the third and fourth premolars, and segments were stabilized with 1 of 5 interdental fixation apparatuses: Erich arch bar (EAB, n = 6); Stout loop (SL, n = 6); acrylic A, n = 6); Stout loop and acrylic (SLA, n = 24); and Erich arch bar and acrylic (EABA, n = 6). Ultimate strengths (mean +/- SEM) of EAB, SL, A, SLA, and EABA were 395 +/- 48; 523 t 57; 1,106 +/- 102; 1,306 +/- 156; and 2,707 +/- 504 N.m, respectively. Stiffness (mean +/- SEM) of EAB, SL, A, SLA, and EABA were 2,944 t 357; 6,322 +/- 2,201; 16,010 +/- 5,017; 15,777 +/- 1,026; and 27,079 +/- 5,576 N.m/ radian, respectively. Yield strengths (mean +/- SEM) Of EAB, SL, A, SIA, and EABA were 66 +/- 6; 264 +/- 19; 911 +/- 126; 1,114 +/- 159; and 1,855 +/- 401 N.m, respectively. There were no significant differences in acrylic weight, cross-sectional area of the acrylic, or area moment of inertia of acrylic at the osteotomy site among A, SIA, and EABA; and there were no significant differences in osteotomy surface area and area moment of inertia at the osteotomy site among all apparatuses (P > 0.05). The EABA apparatus had significantly higher mean ultimate strength, mean stiffness, and mean yield strength compared to other interdental fixation apparatuses. There were no significant differences in the mean ultimate strength, mean stiffness, or mean yield strength between EAB and SL (P > 0.05). Apparatuses that combine acrylic with metal reinforcement (SLA, EABA) were significantly stronger and stiffer than those that used metal alone (EAB, SL) or acrylic alone (A).
显示更多 [+] 显示较少 [-]In vitro evaluation of four methods of attaching transfixation pins into a fiberglass cast for use in horses.
1996
McClure S.R. | Watkins J.P. | Hogan H.A.
High-speed exercise history and catastrophic racing fracture in Thoroughbreds.
1996
Estberg L. | Stover S.M. | Gardner I.A. | Drake C.M. | Johnson B. | Ardans A.
Radiologic, Ultrasonic and pathological assessments of locally applied estrogen on promotion of experimentally induced tibial fracture healing in rats
2020
Kotb, M. M. A1 | Ragab, G. A.2 | Fathy, M. Z .2 | Haggag, U.2 | Nesreen. M. Safwat3
The objective of the present study was to evaluate the ability of estrogen to promote induced tibial fracture healing in a rat model. The study was conducted on 14 albino rats divided into two equal groups (seven rats in each group). The first group considered as a control group. The second group was injected estradiol solution 0.1 mg/kg into the fracture gap. The progress of healing in each group was evaluated by clinical, radiography, ultrasonography and pathological examinations. The healing process was observed to be superior in the estrogen group compared to the control one. Estrogen was found to promote healing of injured bone and is suggested to be used in cases of complicated or delayed bone fracture.
显示更多 [+] 显示较少 [-]Radiologic, Ultrasonic and pathological assessments of locally applied Chitosan on promotion of experimentally induced tibial fracture healing in rats
2020
Kotb, M. M. A1 | Ragab, G. A.2 | Fathy, M. Z.2 | Haggag, U.2 | Nesreen M. Safwat3
The objective of the present study was to evaluate the ability of Chitosan to promote induced tibial fracture healing in a rat model. The study was conducted on 14 albino rats divided into two equal groups (seven rats in each group). The first group was considered as a control group. The second group was injected Chitosan solution 0.1 mg/kg into the fracture gap. The progress of healing in each group was evaluated by clinical, radiography, ultrasonography and pathological examinations. The healing process was observed to be superior in the Chitosan group compared to the control one. Chitosan was found to promote healing of injured bone and is suggested to be used in cases of complicated or delayed bone fracture.
显示更多 [+] 显示较少 [-]Experimental fracture healing with external skeletal fixation in a pigeon ulna model
2014
Ahmed Tunio | Abu Jalila | Goh Yong Meng | Intan Shameha
This study was conducted to assess the healing of transverse ulna fracture when fixed with external skeletal fixation (ESF) in pigeon. Ulna fracture was created under Isoflurane anesthesia in pigeons. A total of 12 pigeons were used in this study, and they were divided into three equal groups: Group-1, Group-2 and Group-3. The birds of the three groups were sacrificed at 3, 6, and 12 weeks after successful fracture surgery. It was found that bone union occurred between three and six weeks in all groups. Bone alignment, and callus remodeling were evident at 12 weeks (p<0.05) post fracture fixation. There were no radiographic evidence of callus remodeling in any bird at 3 and 6 weeks post-surgery. The radiographic observations of fracture healing in this study have confirmed that ESF fixation is an effective method to stabilize ulna fracture in pigeons and results in faster fracture healing.
显示更多 [+] 显示较少 [-]Biomechanical comparison of bone staple techniques for stabilizing tibial tuberosity fractures
2023
Park, K.T. | Lee, M.Y. | Kim, H.Y.
This study compared the biomechanical properties of bone-stapling techniques with those of other fixation methods used for stabilizing tibial tuberosity fractures using 3-dimensionally (3D)-printed canine bone models. Twenty-eight 3D-printed bone models made from computed tomography scan files were used. Tibial tuberosity fractures were simulated using osteotomy. All samples were divided into 4 groups. Group 1 was stabilized with a pin and tension-band wire; group 2, with a pin and an 8 mm-wide bone staple; group 3, with 2 horizontally aligned pins and an 8 mm-wide bone staple; and group 4 with a 10 mm-wide bone staple. Tensile force was applied with vertical distraction until failure occurred. The load and displacement were recorded during the tests. The groups were compared based on the load required to cause displacements of 1, 2, and 3 mm. The maximum failure loads and modes were recorded. The loads at all displacements in group 4 were greater than those in groups 1, 2, and 3. The loads at 1, 2, and 3 mm displacements were similar in groups 1 and 3. There was no significant difference between groups 1 and 3. Groups 1 and 4 provided greater maximum failure loads than groups 2 and 3. Failure occurred because of tearing of the nylon rope, tibial fracture, wire breakage, pin bending, and fracture around the bone staple insertion. In conclusion, these results demonstrate that the bone-stapling technique is an acceptable alternative to tension-band wire fixation for the stabilization of tibial tuberosity fractures in canine bone models.
显示更多 [+] 显示较少 [-]INCIDENCE OF METACARPAL AND METATARSAL FRACTURES IN GOATS (2020-2023)
2023
S. Kokila | S. Dharmaceelan | S. Kathirvel | P. Balachandran | A. Arivuchelvan
Fracture comprises one of the major surgical cases having serious impinge on small ruminants causing lameness. A retrospective study was undertaken on incidence of long bone fractures in reference to metacarpal and metatarsal in goats. Among 893 cases, 344 (38.5%) cases had fracture. Incidence according to the bone involved; metacarpal (28.4%), metatarsal (22.9%), tibia (15.9%), femur (14.2%), radius and ulna (11%) and humerus (8.13%). Fractures with special reference to the age, sex, nature, type, location in metacarpal and metatarsal were taken for the study. The age of animals with metacarpal fracture ranged from twenty days to 3 years and had a mean age of 9 months whereas metatarsal fracture ranged from one month to 2.5 years and had a mean age of 1.2 years. Out of 176 goats with metacarpal (98) and metatarsal (76) fractures, male goats (65.3%) and (68.4%) were mostly affected than female. Open fractures were 33% whereas closed fractures were of 67%. Fracture due to automobile accident in metacarpal (45.9%) and metatarsal (31.5%) was found to be the most common cause of fracture in goats.
显示更多 [+] 显示较少 [-]Effect of electrical stimulation and vitamin AD3E on fracture healing in a rat model
1997
Bae, C.S. | Cho, Y.S. | Chang, K.J. (Konkuk University, Seoul (Korea Republic). Department of Veterinary Medicine)