细化搜索
结果 1-10 的 67
Intraocular pressure measurement through two types of plano therapeutic soft contact lenses in dogs.
1995
Miller P.E. | Murphy C.J.
Intraocular pressure (IOP) was measured by use of Mackay-Marg applanation tonometry in 8 normal, manometrically controlled, enucleated, canine eyes with and without 1 of 2 piano therapeutic soft contact lenses (1 and 2) covering the cornea. Differences were not significant between measurements made without a contact lens and those made through either lens at manometer IOP < 30 mm of Hg. At manometer IOP greater than or equal to 30 mm of Hg, use of a contact lens tended to result in a statistically greater (P < 0.05) estimate of IOP than when a lens was not used. This difference, however, achieved only a maximum of 2.6 mm of Hg at the 80 mm of Hg value, and was not regarded as clinically important. Measurements obtained through lens 1 were not significantly different from those obtained through lens 2. The IOP can be accurately estimated in dogs; using the Mackay-Marg tonometer, without removing either type of bandage soft contact lens, thereby avoiding potential disruption of an already compromised cornea.
显示更多 [+] 显示较少 [-]Comparison of a visual analogue scale and a numerical rating scale for assessment of lameness, using sheep as a model.
1993
Welsh E.M. | Gettinby G. | Nolan A.M.
A study was designed to compare use of an numerical rating scale (NRS) and a visual analogue scale (VAS) for subjective assessment of lameness, using sheep as a model. The NRS consisted of 5 divisions, 0, 1, 2, 3, and 4; 4 of these divisions (1-4) described lameness. The VAS used a 100-mm horizontal line with vertical bars at either end; one end was labeled 'sound' and the other was labeled 'could not be more lame.' Two independent observers graded lameness in 62 sheep, and between- and within-observer differences were assessed for each scoring system to compare the NRS with the VAS. Results indicated no significant differences between the 2 observers scoring lameness, using either the VAS or the NRS. The scores obtained, using the VAS, were not normally distributed, although differences between scores for the 2 observers were. The NRS scores followed a normal distribution pattern. Investigation of repeated measurement for the same sheep, using both scales, revealed no significant difference between either. A comparison of the NRS and VAS scores made by each observer indicated that although correlation was good (observer 1; r = 0.94; observer 2; r = 0.95), there was not perfect agreement. The maximal NRS score of 4 was associated with VAS values > 68 mm, indicating that the NRS divisions did not reflect equal increases in lameness. The VAS and NRS scores for each observer were highly reproducible, although they were more variable for sheep that were regarded as moderately lame. Results indicate that although the NRS and VAS compared favorably with respect to repeatability, reproducibility, and use by 2 observers, the VAS is inherently more sensitive. In addition, the NRS and VAS should not be used interchangeably.
显示更多 [+] 显示较少 [-]Effect of titanium endoprostheses on bone mineral density measurements, using quantitative computed tomography.
1992
Markel M.D. | Morin R.L. | Roy R.G. | Gottsauner Wolf F. | Chao E.Y.S.
Quantitative computed tomography has been used extensively to measure bone mineral density; particularly in the vertebral column and in the proximal portion of the femur in human beings with osteoporosis. Other potential applications of this technique include evaluation of bone adjacent to metallic endoprostheses and evaluation of fractures as they heal. Unfortunately, metal causes severe image degradation, principally seen as starburst streaking. One method used to decrease these artifacts is by imaging less-attenuating materials, such as titanium alloy. Titanium decreases image degradation sufficiently to allow accurate determination of the geometric properties of cadaveric bone. In our study, the effect of a titanium segmental endoprosthesis on bone mineral density measurement was determined by use of bone specimens from dogs and calibration standards. Titanium decreased the bone mineral density of calibration solutions from 6.8 (500 mg/cm3) to 17.7% (250 mg/cm3), and increased bone mineral density of cortical bone by 5.3%. Titanium did not affect the repeatability of these scans, indicating that the error caused by titanium was systematic and can be corrected. Our data were suggestive that quantitative computed tomography can be used to measure bone mineral density of cortical bone adjacent to titanium endoprostheses, with a predictable increase in density measurement.
显示更多 [+] 显示较少 [-]Evaluation of an automated system for hemoglobin measurement in animals.
1992
Callan M.B. | Giger U. | Oakley D.A. | Scotti M.V. | Shofer F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
显示更多 [+] 显示较少 [-]Electroretinogram and visual-evoked potential measurements in Holstein cows.
1986
Strain G.M. | Olcott B.M. | Hokett L.D.
Evaluation of the wick catheter as used to measure intracompartmental muscle pressure in equine muscle.
1985
McDonnell W.N. | Pascoe P.J. | Lindsay W.A. | Burgess M.L.F.
Effects of tendon grip technique (frozen versus unfrozen) on in vitro surface strain measurements of the equine deep digital flexor tendon.
1996
Matthews G.L. | Keegan K.G. | Graham H.L.
Biomechanical study of the effect of coxofemoral positioning on passive hip joint laxity in dogs.
1993
Heyman S.J. | Smith G.K. | Cofone M.A.
Ten coxofemoral joints from 5 dog cadavers were used to study the effect of coxofemoral positioning on passive hip laxity. A material test system was used to measure lateral translation when force was between 20 N of compression and 40 N of distraction. Using the orthogonal coordinate system imposed in this study, neutral position was empirically defined at 15 degrees of extension and 10 degrees of abduction, relative to the plane of the pelvis, and no internal or external rotation of the femur. The hips were mounted in a custom-designed jig that allowed 1 rotational degree of freedom (ie, either flexion/extension, adduction/abduction, or internal/external rotation), while holding the other 2 constant. Lateral translation of the hips was tested at 10 degrees intervals from 30 degrees of flexion to 70 degrees extension, 40 degrees of adduction to 60 degrees of abduction, and 30 degrees of internal rotation to 40 degrees of external rotation. Lateral displacement was maximal at 10 degrees of extension, 20 degrees of abduction, and 10 degrees of external rotation, approximating the neutral coxofemoral position during stance. As the hips were rotated into extreme positions, the amount of lateral displacement occurring with the same applied load decreased significantly to 32.0 to 65.3% of the maximal displacement. Determining the position of the hip associated with maximal passive laxity in vitro is essential to the design of a precise and accurate clinical stress-radiographic method to quantitate joint laxity in dogs. Our results confirm earlier work that passive hip joint laxity is at a maximum with the hip approximately in a neutral weight-bearing position.
显示更多 [+] 显示较少 [-]Endogenous creatinine clearance measurement of glomerular filtration rate in dogs.
1993
Finco D.R. | Tabaru H. | Brown S.A. | Barsanti J.A.
Renal clearance procedures were performed on adult mixed-breed dogs with a wide range of renal function. Endogenous creatinine clearance was computed after analyzing plasma and urine for creatinine by use of 2 methods, PAP and kinetic Jaffe. For 20-minute clearance procedures, [14C]inulin clearance was measured simultaneously with endogenous creatinine clearance. For 111 twenty-minute clearance procedures performed on 24 dogs, [14C]inulin clearance was highly correlated with creatinine clearance for both methods of creatinine analysis (R2 = 0.979 for [14C]inulin-PAP; R2 = 0.943 for [14C]inulin-Jaffe). The absolute values for PAP and [14C]inulin clearance were nearly the same (PAP-to-[14C]inulin clearance ratio = 1.03 +/- 0.08), but those for Jaffe clearance were substantially less than those for [14C] inulin clearance Jaffe-to-[14C]inulin clearance ratio = 0.88 +/- 0.10). The Jaffe-to-[14C] inulin clearance ratio was inversely correlated with degree of renal function (R2 = 0.464), whereas the PAP-to-[14C]inulin clearance ratio was not correlated with degree of renal function (R2 = 0.060). Thus, Jaffe-determined creatinine clearance varied, in relation to [14C] inulin clearance, depending on degree of renal function. In 4 clinically normal dogs, 20-minute and 24-hour sample collections analyzed by use of the PAP method gave clearance values significantly greater, for both periods, than did Jaffe analyses. The PAP-determined creatinine clearance values were less than, but not significantly different from 20-minute exogenous creatinine clearance values determined 10 days after 24-hour collections. For 20-minute and 24-hour collections, the difference in clearance values between the PAP and Jaffe methods was attributable mostly to lower plasma creatinine values for the PAP method (mean +/- SEM, plasma PAP-to-Jaffe ratio = 0.798 +/- 0.053). However, urine creatinine values also were less by use of the PAP method.
显示更多 [+] 显示较少 [-]Use of laser Doppler flowmetry to determine blood flow in and viability of island axial pattern skin flaps in rabbits.
1990
Lanthier T. | Miller C. | McDonell W.N. | Yager J.A. | Roth J.H.
Perfusion and viability of island axial pattern skinflaps were tested in 37 healthy New Zealand white rabbits, using laser Doppler monitoring of blood flow in the capillary loops and the subpapillary plexus of the dermis. Skin flaps, selected on the basis of the caudal superficial epigastric vein and artery, were lifted and replaced in their original locus after selective occlusion of their vascular pedicles. Subjects were allotted into groups: control group (n = 10); arterial occlusion (n = 7); venous occlusion (n = 10); and arterial and venous occlusion (n = 10). The rabbits were monitored from 48 hours before surgery until euthanasia 48 to 72 hours after replacement of the flap. Flap viability was assessed on a clinical basis, using a comparative scoring method based on a numeric scale. The degree of necrosis in histologic sections was evaluated, using a scoring system. Laser Doppler measurements were obtained on 3 consecutive days before surgery, to establish the normal basal blood flow in the skin. Postsurgical measurements were obtained at 2-hour intervals for the first 8 hours and at 24, 48, and 72 hours after surgery. Measurements of basal blood flow varied significantly (P < 0.05) from site to site on the surface of individual flaps and over time. When laser Doppler flowmetric (LDF) measurements from 6 sites on a flap were used as a measure of laser Doppler flow for the total flap, there was no significant difference between contralateral flap areas outlined on the abdomen of the rabbits. Temporal variations over 3 days for each rabbit or among rabbits were not significant. The LDF measurements detected acute vascular occlusion when compared with the controls, and were able to differentiate between control and arterial occlusion groups, control and venous occlusion groups, control and arterial and venous occlusion groups, arterial and venous occlusion groups, venous and arterial and venous occlusion groups (P < 0.05), but not between arterial and arterial and venous occlusion groups. Evaluation of LDF values at 4 hours proved to be a better predictor than clinical assessment at 4 or 8 hours in evaluating skin flap viability.
显示更多 [+] 显示较少 [-]